Technical data
The technical data given in this document is subject to
change without prior notification. Please refer to cp.com.
in.
mm
in.
mm
lb
kg
B16BV
0.92
23.5
11
0.43
2400 6.5
2.95
B16MV
0.92
23.5
11
0.43
2400 5.18
2.35
B18BV
0.92
23.5
11
0.43
2400 7
3.2
B18MV
0.92
23.5
11
0.43
2400 5.9
2.7
B19BV
1.35
34.4
20
0.79
3000 9.36
4.25
B19MV
1.35
34.4
20
0.79
3000 7.74
3.51
(dB(A))
(m/s
2
)
K (m/s
2
)
B16BV
89
2.7
1,2
B16MV
86
4.8
2,2
B18BV
88
2.7
1,2
B18MV
86
5
1,9
B19BV
93
4.2
2,6
B19MV
88
4.6
1,7
Declarations
EU DECLARATION OF CONFORMITY
We,
CHICAGO PNEUMATIC Tool Co. LLC
, 1815 Club-
house Road, Rock Hill, SC 29730, declare under our sole re-
sponsibility that the product (with name, type and serial
number, see front page) is in conformity with the following
Directive(s):
2006/42/EC (17/05/2006)
Harmonized standards applied:
EN ISO 11148-4 : 2012
Authorities can request relevant technical information from:
Pascal Roussy, R&D Manager, Ets Georges Renault, 38 rue
Bobby Sands, BP10273 44818 Saint Herblain, France
Saint-Herblain,
Pascal ROUSSY
Signature of issuer
Noise and vibration
Uncertainty 3 dB(A), in accordance with EN ISO 15744. For
Sound power level, add 11 dB(A)
Vibration standard : ISO-28927-9
These declared values were obtained by laboratory type test-
ing in accordance with the stated standards and are suitable
for comparison with the declared values of other tools tested
in accordance with the same standards. These declared val-
ues are not adequate for use in risk assessments and values
measured in individual work places may be higher. The ac-
tual exposure values and risk of harm experienced by an indi-
vidual user are unique and depend upon the way the user
works, the workpiece and the workstation design, as well
upon the exposure time and the physical condition of the
user.
We,
CHICAGO PNEUMATIC Tool Co. LLC
, cannot be
held liable for the consequences of using the declared values,
instead of values reflecting the actual exposure, in an individ-
ual risk assessment in a work place situation over which we
have no control.
This tool may cause hand-arm vibration syndrome if its use
is not adequately managed. An EU guide to managing hand-
arm vibration can be found by accessing
and selecting 'Tools' then 'Legis-
lation'.
We recommend a programme of health surveillance to detect
early symptoms which may relate to noise or vibration expo-
sure, so that management procedures can be modified to help
prevent future impairment.
If this equipment is intended for fixtured applications:
The noise emission is given as a guide to the machine-
builder. Noise and vibration emission data for the com-
plete machine should be given in the instruction manual
for the machine.
Statement of use
This product is designed for chipping, riveting, scaling, or
ramming, according to its operating instructions. No other
use permitted. For professional use only.
Product specific instructions
Operation
• Fix the accessories properly to the tool.
• Connect device to a clean and dry air supply.
• To start the machine, Pull the trigger (A).
• Remember that it is always the tool that must do the
work. There is no need for the operator to apply extra
pressure on the tool when it is working. Maintain the
contact with the work surface by applying enough pres-
sure to stop the tool from bouncing.
Lubrication
Use an air line lubricator with SAE #10 oil, adjusted to two
(2) drops per minute.
Maintenance instructions
•
Follow local country environmental regulations for
safe handling and disposal of all components.