background image

To reduce risk of injury, everyone using, installing, 
repairing, maintaining, changing accessories on, or 
working near this tool must read and understand 
these instructions before performing any such task.

The goal of Chicago Pneumatic is to produce tools that help you work safely and 
efficiently. The most important safety device for this or any tool is YOU. Your 
care and good judgment are the best protection against injury. All possible 
hazards cannot be covered here, but we have tried to highlight some of the 
important ones.

We, Chicago Pneumatic Tool Company, 1800 Overview Drive, Rock Hill, SC 29730 USA, 
declare under our sole responsibility that the product to which this declaration relates, is in 
conformity with the requirements of the Council Directive of June 1989 on the approximation of 
the laws of the Member States relating to machinery (89/392/EEC).

Machine Name

 CP865 S/P Sander/Polisher

Machine Type

 Power tool equipped with flexible disc fitted with a polishing pad for 

buffing and polishing - No other use is permitted.

Serial No.

 Tools with No. 94200L/K or higher

Technical Data

Buff diameter 8 in. (203 mm)
Free speed 5000 RPM (CP865S), 2,750 RPM (CP865P)
Air pressure 90 psi (6.2 bar)
Air consumption 11.3 cfm
Spindle size 5/8 in.-11

Harmonized Standards Applied

 EN292

National Standards Applied

 ISO 8662-1, Pneurop 8N-1

Name and Position of Issuer

 W. A. LeNeveu, President, Chicago Pneumatic Tool 

Company

Signature of Issuer
Place and Date of Issue 

Utica, NY  13501 USA, July 31, 1994

Air Supply Requirements

1. Supply tool with 90 psig (6.2 bar) of clean, dry air. Higher pressure drastically 

reduces tool life.

2. Connect tool to air line using pipe, hose and fitting sizes shown in the diagram 

on page 12.

3. Do not install a quick coupler directly into the sander throttle handle. Minimum 

compressor requirement: 3 hp (2238 w), 60 gal. (227 l) air tank.

Lubrication

Use an air line lubricator with SAE #10 oil, adjusted to two drops per minute. If 
an air line lubricator cannot be used, add air motor oil to the inlet once a day.

Noise & Vibration Declaration*

(CP865S)

2

Vibration value < 2.5 m/s , re. ISO 8662-1, (CP865S).

(CP865P)

2

Vibration value < 2.5 m/s , re. ISO 8662-1, (CP865P).

Maintenance

1. Disassemble and inspect air motor every three months if the tool is used every 

day. Replace damaged or worn parts.

2. To keep downtime to a minimum, the following service kit, detailed on page 12, 

is recommended:  KF132239 Tune-Up Kit

*These declared values were obtained by laboratory type testing in compliance with the stated standards and 
are not adequate for use in risk assessments. Values measured in individual work places may be higher than 
the declared values. The actual exposure values and risk of harm experienced by an individual user are 
unique and depend upon the way the user works, the workpiece and the workstation design, as well as upon 
the exposure time and the physical condition of the user. We, Chicago Pneumatic, cannot be held liable for 
the consequences of using the declared values, instead of values reflecting the actual exposure, in an 
individual risk assessment in a work place situation over which we have no control.

Sound pressure level 89 dB(A) in accordance with Pneurop 8N-1.  For sound 
power, add 10 dB(A). 

Sound pressure level 87 dB(A) in accordance with Pneurop 8N-1.  For sound 
power, add 10 dB(A). 

CP865 S/P 

Sander/Polisher

Model  

KF136466 Rev. F

"L/K"

Limited Warranty:   The "Products" of the Chicago Pneumatic  Tool Company ("CP") are warranted to  be 
free from defects in material and workmanship  for one year from the date of  purchase.  This Warranty  
applies only to Products purchased new from  CP or its authorized dealers.   Of course, this Warranty 
does not apply to products which have  been abused, misused, modified, or repaired by  someone other 
than CP or its Authorized Service  Representatives.  If  a CP Product proves defective in  material or 
workmanship within one year after purchase,  return it to any CP Factory  Service Center or Authorized 
Service Center for CP tools, transportation  prepaid, enclosing your name and address, adequate  proof 
of date of purchase, and a short  description of the defect.   CP will, at its option, repair or  replace defective 
Products free of charge.   Repairs or replacements are warranted as described  above for the remainder 
of the original warranty period.   CP's sole liability and your exclusive  remedy under this Warranty is 
limited to repair or replacement of the  defective Product. 

(There

 

Are

 

No

 

Other

 

Warranties

 

Expressed

 

Or

 

Implied

 

And

 

CP

 

Shall

 

Not

 

Be

 

Liable

 

For

 

Incidental,

 

Consequential,

 

Or

 

Special

 

Damages,

 

Or

 

Any

 

Other

 

Damages,

 

Costs

 

Or

 

Expenses

 

Excepting

 

Only

 

The

 

Cost

 

Or

 

Expense

 

Of

 

Repair

 

Or

 

Replacement

 

As

 

Described

 

Above.)

 

For Additional Safety Information Consult:

!

Your employer, union and/or trade association.

!

US Department of Labor (OSHA);www.osha.gov; Council of the 
European Communities europe.osha.eu.int

!

Safety Code for Portable Air Tools (B186.1) and Safety Requirements 
for Abrading Materials with Coated Abrasives (B7.1) available from: 
www.ansi.org

!

Safety Requirement for Hand-Held Non-Electric Power Tools available 
from: European Committee for Standardization, www.cenorm.be

Air Supply And Connection Hazards

!

Air under pressure can cause severe injury.

!

Always shut off air supply, drain hose of air pressure and disconnect tool 
from air supply when not in use, before changing accessories or when 
making repairs.

!

Never direct air at yourself or anyone else.

!

Whipping hoses can cause serious injury. Always check for damaged or 
loose hoses and fittings.

!

Do not use quick disconnect couplings at tool. See instructions for 
correct setup.

!

Whenever universal twist couplings are used, lock pins must be 
installed.

!

Do not exceed maximum air pressure of 90 psi/6.2 bar or as stated on 
tool nameplate.

Projectile Hazards

!

Always wear impact-resistant eye and face protection when involved 
with or near the operation, repair or maintenance of the tool or changing 
accessories on the tool.

!

Be sure all others in the area are wearing impact-resistant eye and face 
protection.

!

Even small projectiles can injure eyes and cause blindness.

Entanglement Hazards

!

Keep away from moving sand pad.

!

Do not wear jewelry or loose clothing.

!

Scalping can occur if hair is not kept away from the tool and accessories.

!

Choking can occur if neckwear is not kept away from the tool and 
accessories.

Operating Hazards

!

Never mount a grinding wheel on a sander. A grinding wheel that bursts 
can cause very serious injury or death when not properly guarded.

!

Use only coated abrasive sanding discs or sheets properly secured to 
the backing pad provided with the air sander. 

!

Inspect backing pad before each use. Do not use if cracked or damaged.

!

Avoid direct contact with moving sanding pad to prevent pinching or 
cutting of hands or other body parts. Wear gloves to protect hands.

!

Operators and maintenance personnel must be physically able to handle 
the power of the tool and capable of performing the job task.

!

When using a tool that is designed to have a guard, the guard should be 
in place to offer protection from grinding swarf or flying debris.

Workplace Hazards

!

Slip/Trip/Fall is a major cause of serious injury or death. Be aware of 
excess hose left on the walking or work surface.

!

Maintain a balanced body position and secure footing.

!

High sound levels can cause permanent hearing loss. Use hearing 
protection as recommended by your employer or OSHA regulation (see 
29 CFR part 1910).

!

Repetitive work motions, awkward positions and exposure to vibration 
can be harmful to hands and arms. If numbness, tingling, pain or 
whitening of the skin occurs, stop using tool and consult a physician.

!

Avoid inhaling dust or handling debris from the work process which can 
be harmful to your health. Use dust extraction and wear respiratory 
protective equipment when working with materials which produce 
airborne particles.

!

This tool is not intended for use in explosive atmospheres and is not 
insulated for contact with electric power sources.

!

Some dust created by power sanding, sawing, grinding, drilling and other 
construction activities contains chemicals known to the State of 
California to cause cancer and birth defects or other reproductive harm. 
Some examples of these chemicals are:

- Lead from lead based paints
- Crystalline silica bricks and cement and other masonry products
- And Arsenic and chromium from chemically-treated rubber

Your risk from these exposures varies, depending on how often you do 
this type of work. To reduce your exposure to these chemicals: work in a 
well ventilated area, and work with approved safety equipment, such as 
dust masks that are specially designed to filter out microscopic particles.

Summary of Contents for CP865 S/P

Page 1: ...ribed above for the remainder of the original warranty period CP s sole liability and your exclusive remedy under this Warranty is limited to repair or replacement of the defective Product There Are N...

Page 2: ...cubrir todas la reparaciones o sustituciones de productos que tengan lugar dentro del plazo de garant a original La nica responsabilidad de CP y la compensaci n exclusiva al usuario en esta Garant a...

Page 3: ...cas tre tenu responsable des dommages accidentels indirects ou autres ni des frais encourus l exception du co t de la r paration ou du remplacement dans lescas stipul sci dessus Risques d fonctionneme...

Page 4: ...vi sono altre garanzie esplicite o implicite e inoltre la CP non sar responsabile di danni incidentali indiretti o speciali o per altri danni costi o spese eccezione fatta per i costi o le spese di r...

Page 5: ...e av den defekta produkten Den ovan n mnda garantin ges med uteslutande av alla andra garantier eller villkor uttryckta eller underf rst dda CP ska inte h llas ansvarig f r oavsiktliga skador f ljdska...

Page 6: ...e oder CP bernimmt keinerlei Haftung f r mittelbare oder unmittelbare Folgesch den oder Kosten mit Ausnahme der beschriebenen Reparatur oder Ersatzleistungen stillschweigende Gew hrleistung Zus tzlich...

Page 7: ...N oExistemQuaisquerOutrasGarantiasExpressas OuImpl citasECPN o Ser Respons vel Por Danos Especiais Consequenciais Ou Supervenientes Ou Quaisquer Outros Danos Custos Ou Despesas Excepto Apenas O Custo...

Page 8: ...edet for alle andre garantier eller vilk r det v re seg uttrykte eller underforst tte inkludert alle garantier eller vilk r ang ende salgbarhet eller hensiktsmessighet for et bestemt form l CP skal ik...

Page 9: ...fecte Produkt Er Worden Geen Andere Garanties Bedoeld Of Ge mpliceerd En CP Is Niet Aansprakelijk Voor Incidentele Indirecte Of Speciale Schade Of Enige Andere Schade Kosten Of Uitgaven En Vergoedt Al...

Page 10: ...produkt Denne ovenst ende garanti tr der i stedet for alle andre garantier eller betingelser udtrykte og underforst ede inklusive enhver garanti eller betingelse for salgbarhed eller egnethed til bes...

Page 11: ...tta koskevat takuut ja ehdot CP ei vastaa satunnaisista v lillisist tai muista erityisist vahingoista tai muista suorista tai ep suorista vahingoista kustannuksista tai kuluista muuntoin kuin n iss ta...

Page 12: ...RINTED IN JAPAN KEK 09 01 FOR DETAILED INFORMATION ABOUT CHICAGO PNEUMATIC AIR TOOLS AND EQUIPMENT CONTACT Desoutter GMBH Paul Friedlander Str 65203 Wiesbaden Germany Telephone 49 0611 270120 22 FAX 4...

Reviews: