21.0 ROUTINE MAINTENANCE FOR TRAINED PERSONNEL
BEFORE CARRYING OUT ANY MAINTENANCE IT IS MANDATORY TO STOP THE COMPRESSOR AND
DISCONNECT IT FROM THE MAIN POWER.
MAINTENANCE SCHEDULE
These maintenance intervals are recommended for work environments that are not dusty and are well ventilated. For
particularly dusty environments, double the frequency of maintenance.
Every 50 working hours
Drain condensate from the sump tank
Check the oil level
Clean the filter panel
Every 500 hours
Clean the air suction filter
(see controller LED)
Check belt tension
Every 2000 hours
Change the oil filter
(see controller LED)
Change the suction filter
(see controller LED)
Every 4000 hours
Clean the finned surface of the air-oil cooler
Change the oil separating filter
(see controller LED)
Change belt
Every 8000 hours
Change the oil
Maintenance overhaul on entire compressor
THE OPERATIONS MARKED
ARE DESCRIBED IN PART "A" OF THIS MANUAL ON SECTION 15.3