• The cooling water outlet temperature of the compressor
Modifying settings
If the programmed warning settings for the water temperatures are exceeded, a warning indication is shown
on the Elektronikon:
Temperature input
Minimum
setting
Nominal
setting
Maximum
setting
Water inlet temperature of energy recovery
˚C
0
50
99
Water inlet temperature of energy recovery
˚F
32
122
210
Delay at warning signal
sec
0
Consult your
customer
centre
255
Delay at start ( should be less than delay at
warning signal )
sec
0
Consult your
customer
centre
255
Energy recovery water outlet temperature
˚C
0
Depends on
application
99
Energy recovery water outlet temperature
˚F
32
Depends on
application
210
Delay at signal
sec
0
Consult your
customer
centre
255
Delay at start ( should be less than delay at
signal )
sec
0
Consult your
customer
centre
255
Recoverable energy
The recoverable energy can be calculated from:
RECOVERED ENERGY (kW) = 4.2 x water flow (l/s) x water temperature rise (˚C)
In the tables below, typical examples are given.
Data for low temperature rise/low water flow systems
Typical values
Parameters
Units
30kW
37kW
45kW
Recoverable energy kW
20
24,67
30
Water flow
l/Min
28,93
35,67
43,4
Temperature at inlet °C
50
50
50
Temperature at
outlet
°C
60
60
60
Pressure drop
bar
0,151
0,22
0,22
Instruction book