Warnings
The operator must apply all relevant
Removing the front panel (service panel) during operation will lead to an automatic
shutdown of the unit after a certain time depending of the compressor version.
Keep the doors closed during operation; they may be opened for short periods only to carry
out checks.
When the motors are stopped and LED (3) (automatic operation) is alight, the motors may
start automatically.
Regulator
Checking the oil level
Position of oil level sight-glass
Regularly check the oil level. To do so:
1. Press stop button (11).
2. A few minutes after stopping, the oil level should be between the oil filler neck (FC) and the top of
the sight glass (Gl).
3. If the oil level is too low, push the emergency stop button to avoid the compressor to start
unexpectedly.
4. Next, close the air outlet valve and open the manual drain valve (Dm) until the air system between oil
separator/air receiver vessel and outlet valve is fully depressurized.
5. Unscrew oil filler plug (FC) one turn to permit any pressure left in the system to escape. Wait a few
minutes.