Step
Action
-
Press the test button on the top of the electronic water drain(s) until the air system between
the air system receiver and the outlet valve is fully depressurised. See section
Switch off the voltage.
-
If available, open the condensate drain valve of the compressor (Dm) to drain the water trap
completely.
-
On water-cooled compressors:
• Close the cooling water inlet valve.
• If freezing temperatures can be expected, drain the cooling system completely.
5.7
Taking out of operation
Procedure
Step
Action
-
Stop the compressor and close the air outlet valve.
-
Switch off the voltage and disconnect the compressor from the mains.
-
If available, open the condensate drain valve(s) (Dm).
-
Shut off and depressurise the part of the air net which is connected to the outlet valve.
Disconnect the compressor air outlet pipe from the air net.
-
On water-cooled compressors:
• Isolate and disconnect the water system from the cooling water net.
• Drain the water circuit.
-
Drain the oil.
-
Drain the condensate circuit and disconnect the condensate piping from the condensate net.
Instruction book
2920 7101 41
61