Example of protection screens
Protection setting element outlet temperature
Warning alarm high element outlet temperature
Changing the settings
Starting from the Main screen (the example given describes the protection of the element outlet
temperatures):
Press Scroll buttons (12) until <Pr.> followed by a number and the element outlet temperature pictograph is
shown and press Enter button (13):
• The warning level for the high temperature warning level <AL-H> and the high temperature shut-
down level <Sd-H> become visible. Use Scroll keys (12) to move between the warning level (<AL>)
and the shut-down level (<Sd>), press the Enter button (13) to modify the value.
• An optional password may be required, the value starts blinking and Scroll buttons (12) can be used
to modify the value.
• Press the Enter button (13) to program the new value.
Programmable settings can only be modified within allowed limits.
3.31 Test screens
Display test
Starting from the Main screen, press Scroll buttons (12) until <t. 1> is shown and then press Enter button
(13).
The display now shows all icons that can be displayed:
Instruction book
44
2920 7101 41