6. Remove the plug and add oil until the level reaches the filler opening.
7. Fit and tighten the plug (FC).
8. Unlock the emergency stop button and press the "Reset key" on the controller before restarting
5.5
Automatic restarting
Description
The electronic controller has a built-in function to automatically restart the compressor when the voltage is
restored after voltage failure.
Whenever the compressor is shut down, the emergency push-button must be pressed or
the electricity isolating switch opened.
5.6
Stopping
Regulator
Control panel ES 4000 Std
Procedure
Step
Action
-
Press stop button (11). Automatic operation LED (3) goes out and the compressor stops after
30 seconds of unloaded operation.
-
To stop the compressor in the event of an emergency,
press emergency stop button.
Alarm LED flashes (5).
On compressors with an Standard controller:
• Remedy the problem cause and unlock the button by pulling it out
• Press the Escape button (13) to reset.
Do not use emergency stop button for normal stopping!
-
Close the air outlet valve (AV).