Maximum air inlet temperature
˚F
115
Minimum ambient temperature
˚C
0
Minimum ambient temperature
˚F
32
On water-cooled units also:
Maximum cooling water outlet temperature
˚C
50
Maximum cooling water outlet temperature
˚F
122
Maximum cooling water inlet temperature
˚C
35
Maximum cooling water inlet temperature
˚F
95
Maximum cooling water inlet pressure
bar(e)
5
Maximum cooling water inlet pressure
psig
72.5
9.3
Compressor data
Reference conditions
All data specified below apply under reference conditions, see section
Gearbox driven units
Units
7.5 bar 8 bar
10 bar
13 bar
100 psi 125 psi 150 psi 175 psi
Frequency
Hz
50
50
50
50
60
60
60
60
Nominal working
pressure
bar(e) 7
8
9.5
12.5
6.9
8.6
10.3
12
psig
102
116
138
181
100
125
150
175
Maximum working
pressure
bar(e) 7.5
8
10
13
7.4
9.1
10.8
12.5
psig
109
116
145
189
107
132
157
181
Unloading pressure
Maximum setting
bar(e) 7.2
8.2
9.7
12.7
7.1
8.8
10.5
12.2
psig
104
119
141
184
103
128
152
177
Unloading pressure
Factory setting
bar(e) 7
8
9.5
12.5
6.9
8.6
10.3
12
psig
102
116
138
181
100
125
150
175
Unloading pressure
Minimum setting
bar(e) 4.1
4.1
4.1
4.1
4.1
4.1
4.1
4.1
psig
59.5
59.5
59.5
59.5
59.5
59.5
59.5
59.5
Loading pressure
Maximum setting
bar(e) 7.1
8.1
9.6
12.6
7
8.7
10.4
12.1
psig
103
117.5
139
183
101.5
126
151
175.5
Loading pressure
Factory setting
bar(e) 6.4
7.6
8.9
11.9
6.3
8
9.7
11.4
psig
93
110
129
173
91
116
141
165
Loading pressure
Minimum setting
bar(e) 4
4
4
4
4
4
4
4
psig
58
58
58
58
58
58
58
58
Instruction book
2920 7101 41
93
Summary of Contents for CPC 40 G
Page 2: ......
Page 128: ......
Page 129: ......
Page 130: ...No 2920 7101 41 2014 12 Printed in Belgium People Passion Performance www cp com ...