Ventilation: the inlet grids and ventilation fan should be installed in such a way that any
recirculation of cooling air to the compressor or dryer is avoided.
The air velocity to the grids must be limited to 5 m/s (200 in/s).
The required ventilation capacity to limit the temperature of the compressor room can be
calculated from the following formula:
Q
v
= 0.92 N / ΔT
Q
v
= Required ventilation capacity in m
3
/s
N = Shaft input of compressor in kW
ΔT = Temperature increase in the compressor room in °C
4.2
Dimension drawings
The dimension drawing can be found on the CD-ROM, DVD or USB, supplied with the unit.
Dimension drawing
Model
9828 0832 60
Floor mounted
9828 0832 61
Tank mounted
9828 0832 62
Tank mounted with dryer
Text on drawings
Translation or explanation
Emergency stop switch
Emergency stop switch
Power supply
Power supply
Cooling air and compressor inlet
Cooling air and compressor inlet
Cooling air outlet of compressor and motor
Cooling air outlet of compressor and motor
Service panel
Service panel
Compressor controller
Compressor controller
Oil level indicator
Oil level indicator
Compressed air outlet (G1/2” Female)
Compressed air outlet
Forklift openings
Forklift openings
Valve rotation
Valve rotation
Centre of gravity
Centre of gravity
Cubicle door fully open
Cubicle door fully open
Anchorpoints in base
Anchorpoints in base
Air receiver safety valve
Air receiver safety valve
Vessel anchor points
Vessel anchor points
Air receiver manual drain (G3/8” Female)
Air receiver manual drain
Dryer dewpoint indicator
Dryer dewpoint indicator
Condensate drain integrated dryer
Condensate drain integrated dryer
Dryer inlet cooling air
Dryer inlet cooling air
Dryer outlet cooling air
Dryer outlet cooling air
Instruction book
2920 7114 70
47
Summary of Contents for QRS 10
Page 2: ......
Page 18: ...2 3 Oil system Oil system Oil system units with dryer Instruction book 16 2920 7114 70 ...
Page 23: ...Electric cubicle UL DOL Instruction book 2920 7114 70 21 ...
Page 51: ...208 230 460V 60Hz Instruction book 2920 7114 70 49 ...
Page 74: ...8 Problem solving Control panel Air outlet valve Instruction book 72 2920 7114 70 ...
Page 75: ...Oil filler plug Condensate drain valve on air receiver Instruction book 2920 7114 70 73 ...
Page 84: ......
Page 85: ......
Page 86: ...No 2920 7114 70 2017 03 Printed in Belgium People Passion Performance www cp com ...