Modifications to the compressor cubicle:
Step
Action
1
Adjust the motor overload (FM1) setting.
2
Control transformer (T1) – Move the primary connection from 230V to the desired voltage.
3
Replace the control fuses (F1) 10.3 x 38mm with the ones provided (see further).
Use 1A fuses for 460V or 2A for 208V
4
Modify the motor terminal bridge configuration in the cubicle (X2). See further for details.
5
Replace the voltage sticker by the appropriate voltage sticker provided.
Motor overload relay (FM1) setting:
Rotate the adjustment screw (1) on the front of the relay to the required value.
Adjustment screw of the motor overload
Motor overload (FM1) settings
7.5 kW
11 kW
15 kW
10 hp
15 hp
20 hp
208 V
36.3
48
33.2
230 V (Standard factory setting)
34.3
45
30
460 V
16.9
22.5
15
Control transformer (T1):
Move the wire to the terminal marked with the desired voltage (208 V, 230 V or 460 V).
Transformer T1
Fuses F1 – F3:
The fuses are supplied with the compressor.
Fuses
fuse rating
(V)
208 V
230 V
460 V
Class
F1
600 V AC
2 A
2 A
1 A
UL class JDYX or JDYX2 10.3 x 38mm
Motor terminal bridge configuration:
Instruction book
50
2920 7114 70
Summary of Contents for QRS 10
Page 2: ......
Page 18: ...2 3 Oil system Oil system Oil system units with dryer Instruction book 16 2920 7114 70 ...
Page 23: ...Electric cubicle UL DOL Instruction book 2920 7114 70 21 ...
Page 51: ...208 230 460V 60Hz Instruction book 2920 7114 70 49 ...
Page 74: ...8 Problem solving Control panel Air outlet valve Instruction book 72 2920 7114 70 ...
Page 75: ...Oil filler plug Condensate drain valve on air receiver Instruction book 2920 7114 70 73 ...
Page 84: ......
Page 85: ......
Page 86: ...No 2920 7114 70 2017 03 Printed in Belgium People Passion Performance www cp com ...