Step
Action
1
Push the start/stop button (6) on the controller. The compressor will unload. When the
unload time is elapsed, the compressor is stopped and the controller goes back to the
main screen.
To stop the compressor immediately in the event of an emergency, press button (S3).
See section
Control panel
. After remedying the fault, unlock the button by pulling it out.
Only use emergency stop button in the event of an emergency. Avoid using the button
for normal stopping of the compressor.
2
Close air outlet valve and switch off the voltage to the compressor.
3
Open condensate drain valve (4) of the air receiver for a few seconds to drain any
condensate and then close the valve.
The air dryer and the air receiver remain under pressure.
The integrated filter (if installed) remains pressurised.
If maintenance or repair work is necessary, consult the
Problem solving
section for all
relevant safety precautions.
5.4
Taking out of operation
Condensate drain valve on air receiver
Instruction book
2920 7114 70
59
Summary of Contents for QRS 10
Page 2: ......
Page 18: ...2 3 Oil system Oil system Oil system units with dryer Instruction book 16 2920 7114 70 ...
Page 23: ...Electric cubicle UL DOL Instruction book 2920 7114 70 21 ...
Page 51: ...208 230 460V 60Hz Instruction book 2920 7114 70 49 ...
Page 74: ...8 Problem solving Control panel Air outlet valve Instruction book 72 2920 7114 70 ...
Page 75: ...Oil filler plug Condensate drain valve on air receiver Instruction book 2920 7114 70 73 ...
Page 84: ......
Page 85: ......
Page 86: ...No 2920 7114 70 2017 03 Printed in Belgium People Passion Performance www cp com ...