Oil filler plug
Testing
The valve can be tested on a separate compressed air line.
Before removing the safety valve, stop the compressor (see section
Stopping
), close the air outlet
valve, switch off the voltage, open drain valves (4) (tank-mounted units) and the manual drain
valve (5) (if fitted - on floor-mounted units) and unscrew filler plug (3) one turn to permit any
pressure in the system to escape.
If the valve does not open at the set pressure stamped on the valve, replace the valve.
No adjustments are allowed. Never run the compressor without a safety valve.
Instruction book
68
2920 7114 70
Summary of Contents for QRS 10
Page 2: ......
Page 18: ...2 3 Oil system Oil system Oil system units with dryer Instruction book 16 2920 7114 70 ...
Page 23: ...Electric cubicle UL DOL Instruction book 2920 7114 70 21 ...
Page 51: ...208 230 460V 60Hz Instruction book 2920 7114 70 49 ...
Page 74: ...8 Problem solving Control panel Air outlet valve Instruction book 72 2920 7114 70 ...
Page 75: ...Oil filler plug Condensate drain valve on air receiver Instruction book 2920 7114 70 73 ...
Page 84: ......
Page 85: ......
Page 86: ...No 2920 7114 70 2017 03 Printed in Belgium People Passion Performance www cp com ...