20
• Sit down comfortably and relax.
• Fit the cup over your breast ensuring that the nipple is
centred properly. You can use the breast pump both with
and without the soft silicone cover (3); We recommend
trying both configurations before choosing the best and
most comfortable one for you.
• Press the on/off button (13) on the motor body (10) to
switch on the breast pump, the display (11) will light up.
• If you are using the breast pump powered by alkaline bat-
teries, the indicator on the display will show the battery
charge status (20). If it is powered by the mains adaptor,
this indicator will not appear. The battery indicator shows
4 levels based on the battery charge status.
NB: while using the breast pump, to ensure correct opera-
tion of the appliance, take care not to cover the hole on the
left-hand side of the pump body (4) with your hand.
NB: when switched on, the breast pump always starts in
stimulation mode to facilitate milk extraction, using the
factory settings (level 5). The stimulation indicator (23) will
appear on the display.
• After approximately 2 minutes of stimulation, the appli-
ance automatically switches to the extraction mode using
the factory settings (level 5). The extraction indicator (24)
will appear on the display.
• You can stop the stimulation stage and switch to the ex-
pression stage by briefly pressing the on/off button.
• If necessary, repeat stimulation by pressing the stimula-
tion/extraction button (16) again. Press the stimulation/
extraction button (16) to return to extraction.
• You can use the “+” (15) and “-” (14) buttons on the keypad
to adjust extraction/stimulation based on the level of pull
perceived on your breast and/or based on the amount of
milk expressed. We recommend adjusting the extraction/
stimulation rate gradually until you reach the level best
suited to you.
• If the level of extraction/stimulation chosen causes dis-
comfort or pain, suitable reduce it by pressing the “-” but-
ton (14).
• You can alternate milk extraction from both breasts.
• Press the on/off button (13) to switch the breast pump off.
• To avoid all danger deriving from spilt liquid (milk), we rec-
ommend that you never fill the feeding bottle beyond the
highest level indicated on its graduated scale.
• WARNING:
immediately after each single use, carefully
clean all the components* as shown in the “
CLEANING
”
paragraph.
• To feed the milk immediately to your baby, unscrew the
feeding bottle from the pump body (4) to remove it.
Screw the ring with the teat (7) (included in the pack)
onto the feeding bottle. This way, you will obtain a handy,
ready-to-use baby feeding bottle.
• If, on the contrary, you close the bottle with the airtight
cap (8) (included in the package) you can store the ex-
pressed milk in the fridge for up to 48 hours at 4°C or for
up to 3 months at -18°C in the freezer.
• In order to avoid the proliferation of bacteria, it is advisa-
ble to feed the baby immediately after the milk has been
collected, or to immediately store the collected milk in the
most appropriate way.
• WARNING:
When the breast pump is not used, always dis-
connect the mains adaptor from the mains.
*Excluding the motor body (10) and mains adaptor (18) and
the silicone tube (17).
CLEANING
• Before and after each single use clean and sanitize the sil-
icone cushion (3), the pump body (4) and the valve (5).
Clean and sanitize the bottle (6) and its accessories (7)-(8)
as illustrated in the related instructions.
• Before carrying out any cleaning operation, disconnect,
if connected, the mains adaptor from the mains and the
power cord connector from the socket (19) on the motor
body.
• Separate all the components from the breast pump.
NB: remove the valve (5), located on the circular duct inside
the base of the pump body (4) by gently pulling the tab on
the side of the valve.
• WARNING:
always remove the valve gently and do not
use any tool to clean it since this may damage it,making
the breast pump impossible to use.
NB: to remove the silicone tube, first detach the membrane
(1) and the membrane cover from the pump body, to avoid
any spillage. Then, holding the end inserted into the mem-
brane cover, gently pull it off.
• Carefully wash all the components* using hot water and
washing up liquid, thoroughly rinse and dry carefully using
a soft and clean cloth.
• Do not use abrasive products to clean the breast pump
and its components.
• Clean the motor body and the mains adaptor with a soft,
clean and dry cloth. Warning! Do not wet the appliance or
put it into water or other liquids.
• The tube may be rinsed and suitably dried.
• All the components, with the exception of the motor body
(10), the mains adaptor (18), the valve (5), the membrane (1),
the silicone cover (3) and the tube (17) may also be washed
in a dishwasher using a delicate programme. This washing
method, which is more aggressive than hand washing, may
discolour or dull and degrade the material over time.
• Also clean and sanitise the feeding bottle (6) and its acces-
sories (7)-(8), according to the instructions included with
the bottle.
• After washing, always store the product in a clean, dry
place.
*Excluding the motor body (10), mains adaptor (18) and the
silicone tube (17).
ACCESSORIES:
- NaturalFeeling 150 ML feeding bottle
00080711000xxx
/
00080811000xxx.
- NaturalFeeling Milk Container
00002257200000
- Where XXX=variable identification code identifying the
country of sale.
- Two nursing pad to be used only to absorb excess
breast milk are supplied free with the appliance (REF
20061770000).
• No accessories other than those recommended must be used.