background image

CMA362

Installation Instructions

6

INSTALLATION

WARNING:

Exceeding the weight capacity can result in

serious personal injury or damage to equipment! It is the
installer’s responsibility to make sure the combined weight of
all components attached to the CMA362 does not exceed
250 lbs (113.3 kg).

The CMA362 is designed to fit a 1" steel pipe, a 1-5/8” wide
Unistrut ceiling channel spanning a maximum of 4 feet, or a
2"x4" wood joist.

The CMA362 includes an opening for a 1-1/2" NPT or NPSM
following ANSI/ASME B1.20.1 (Schedule 40, 0.154" minimum
thickness steel or aluminum - ASTM B221) threaded extension
column (not included) which must be installed into the CMA362
with a minimum of four threads engaged.

IMPORTANT ! :

These installation instructions assume

that a 1" steel pipe, a 1-5/8” wide Unistrut ceiling channel
spanning a maximum of 4 feet, or 2"x4" wood joist has
been properly installed and is in place.

Assembly and Installation

1. 

Place CMA362 assembly (A) on desired mounting

structure. (See Figure 1)

Figure 1

2.

Install and tighten two 3/8-16 x 5" hex head cap screws (D)
and two  3/8" Nylock nuts (F) to fasten CMA362 to mounting
structure. (See Figure 1)

3.

Install 3/8" hex nut (E) to 3/8-16 x 4-1/2" hex head tap bolt
(C). (See Figure 2)

Figure 2

4.

Insert 3/8-16 x 4-1/2" hex head tap bolt (C) through hole on
the CMA362 (A). (See Figure 3)

Figure 3

(D) x 2

(A)

2

Mounting

structure

(F)

(F) x 2

(C) x 1

(E) x 1

3

(C) x 1

(E) x 1

4

(A)

NOTE:

shown for clarity.

Mounting structure not

Summary of Contents for CMA362

Page 1: ...I N S T A L L A T I O N I N S T R U C T I O N S C Clamp Adapter CMA362 ...

Page 2: ...sibility to make sure all components are properly assembled and installed using the instructions provided WARNING Failure to provide adequate structural strength for this component can result in serious personal injury or damage to equipment It is the installer s responsibility to make sure the structure to which this component is attached can support five times the combined weight of all equipmen...

Page 3: ...Installation Instructions CMA362 3 DIMENSIONS DIMENSIONS MILLIMETERS INCHES ...

Page 4: ...l proyector Ziel des Projektors Mira do projector Punto di proiezione Doel van de projector Cible du projecteur Hammer Martillo Hammer Martelo Martello Hamer Marteau Pencil Mark Marcar con lápiz Stiftmarkierung Marcar com lápis Segno a matita Potloodmerkteken Marquage au crayon Drill Hole Perforar Bohrloch Fazer furo Praticare un foro Gat boren Percez un trou Adjust Ajustar Einstellen Ajustar Rego...

Page 5: ...Installation Instructions CMA362 5 TOOLS REQUIRED FOR INSTALLATION PARTS 2 3 32 included 9 16 9 16 3 8 F 2 C 1 G 1 3 8 16 x 4 1 2 B 1 10 24 x 1 4 3 32 A 1 CMA362 assembly D 2 E 1 3 8 16 x 5 3 8 ...

Page 6: ... which must be installed into the CMA362 with a minimum of four threads engaged IMPORTANT These installation instructions assume that a 1 steel pipe a 1 5 8 wide Unistrut ceiling channel spanning a maximum of 4 feet or 2 x4 wood joist has been properly installed and is in place Assembly and Installation 1 Place CMA362 assembly A on desired mounting structure See Figure 1 Figure 1 2 Install and tig...

Page 7: ... 3 8 16 hex nut E as a jam nut to secure the bolt in place See Figure 5 Figure 5 6 Install 1 1 2 extension column not included with a minimum of four threads engaged 7 Secure extension column using 10 24 x 1 4 set screw B See Figure 6 Figure 6 C x 1 E x 1 NOTE not shown for clarity Mounting structure E 5 Mounting A C structure B x 1 A 7 Mounting structure Extension column not included ...

Page 8: ... Company www chiefmfg com 10 13 USA International A 6436 City West Parkway Eden Prairie MN 55344 P 800 582 6480 952 225 6000 F 877 894 6918 952 894 6918 Europe A Franklinstraat 14 6003 DK Weert Netherlands P 31 0 495 580 852 F 31 0 495 580 845 Asia Pacific A Office No 1 on 12 F Shatin Galleria 18 24 Shan Mei Street Fotan Shatin Hong Kong P 852 2145 4099 F 852 2145 4477 ...

Reviews: