Installation Instructions

CTA-111

4

TOOLS REQUIRED FOR
INSTALLATION

The tools required for installation are as follows:

Electric drill and bit set

Stud sensor (mechanical or electronic)

½” box-end wrench or ratchet with ½” socket

13mm box-end wrench or ratchet with 13mm socket

Level

NOTE:

Other tools may be required depending on your
method of installation.

Figure 2. Install Stud Spanning Adapters

INSTRUCTIONS

STEP 1

Installing Top Stud Spanning Adapter to Wall

Install the top 16” stud-spanning adapter, as follows:

NOTE:

The top and bottom stud-spanning adapters
must be mounted to wood studs that are
16” apart on center. See Figure 2.

1. Locate the two 16” stud-spanning adapters (10),

four lag bolts (20), and four flat washers (30).

WARNING

It is the installer’s responsibility to verify that
the structure to which the mount is anchored
will safely support

five times

 the combined load

of all attached components and equipment.

2. Determine a suitable mounting location. Keep in

mind that both stud-spanning adapters (10) must
be mounted to wood studs that are 16” apart on
center.

3. Using a stud sensor, locate the two wood studs

where you will mount the top stud-spanning
adapter (10).

4. Holding the top stud-spanning adapter (10)

against the wall, use a pencil, awl, or small nail
to mark the mounting holes where two pilot
holes will be drilled into the center of the wood
studs. Make sure that the mounting holes in the
unit are level.

5. Using a 15/64” drill bit, drill two pilot holes for

anchoring the top stud-spanning adapter (10).

6. Using two 5/16” lag bolts (20) and two 5/16”

flat washers (30), attach the top stud-spanning
adapter (10) to the wall.

16”

Summary of Contents for Dual Stud Adapter CTA-111

Page 1: ... could affect or void the Factory warranty thoroughly study all instructions and illustrations before you begin to install the CTA 111 Pay particular attention to the Warnings and Cautions in this document If you have any questions about this installation contact Chief Manufacturing at 1 800 582 6480 or 952 582 6480 The CTA 111 Dual Stud Adapter provides a 16 on center mounting solution for the fo...

Page 2: ...orce the mounting surface structural members before installing the mount WARNING Be aware of the potential for personal injury or damage to the equipment if it is not adequately mounted WARNING The installer is responsible for verifying that the mounting surface to which the CTA 111 is anchored will safely support the combined load of all attached components or other equipment WARNING The combined...

Page 3: ...apter to Wall 6 Attaching Front Cover 6 Connecting NPT Pipe or Nipple to Wall Arm 6 INSPECT THE UNIT BEFORE INSTALLING Unpack the carton Carefully inspect the parts for shipping damage Verify contents listed in Table 1 If you are missing any of the listed parts contact Customer Service at 1 800 582 6480 300 Table 1 Shipping Contents ITEM DESCRIPTION QTY 10 16 Spanning Adapter 2 20 5 16 X 2 5 Lag B...

Page 4: ...hers 30 WARNING It is the installer s responsibility to verify that the structure to which the mount is anchored will safely support five times the combined load of all attached components and equipment 2 Determine a suitable mounting location Keep in mind that both stud spanning adapters 10 must be mounted to wood studs that are 16 apart on center 3 Using a stud sensor locate the two wood studs w...

Page 5: ...all arm and its attaching parts three M8 hex nuts 60 three M8 lock washers 50 and three M8 flat washers 40 See Figure 3 2 Using the parts listed in step 1 attach the wall arm to the bottom 16 stud spanning adapter 10 Tighten hex nuts See Figure 3 STEP 3 Attaching Wall Arm to Wall Mounted Top Stud Spanning Adapter 1 Locate the following attaching parts for the wall arm three M8 hex nuts 60 three M8...

Page 6: ... or both knockouts on cover to assist routing to wall through cover 2 Install the front cover using four M4 8mm Phillips head cap screws See Figure 6 STEP 6 REFERENCE ONLY Connecting NPT Pipe or Nipple to Wall Arm 1 Locate M6 x 6mm set screw and 1 1 2 NPT pipe or nipple supplied with TV Mount or purchased separately 2 Connect the 1 1 2 NPT pipe or nipple supplied with TV Mount or purchased separat...

Reviews: