Installation Instructions

CTA-111

5

Figure 3. Attach Chief Wall Arm to Bottom Stud

Spanning Adapter

Figure 4. Attach Wall Arm to Wall-Mounted Stud

Spanning Adapter

STEP 2

Attaching Stud Spanning Adapter to Wall Arm

NOTE

To minimize error, the wall arm is attached to
the bottom stud-spanning adapter (10)

before

the wall arm

and

bottom stud-spanning adapter

are secured to the wall.

Refer to CTA-025 Single Stud Wall Arm
(8809-000027) document for specific
installation instructions to mount the wall arm.

1. Locate the wall arm and its attaching parts [three

M8 hex nuts (60), three M8 lock washers (50),
and three M8 flat washers (40)]. See Figure 3.

2. Using the parts listed in step 1, attach the wall

arm to the bottom 16” stud-spanning adapter
(10). Tighten hex nuts. See Figure 3.

STEP 3

Attaching Wall Arm to Wall-Mounted Top Stud
Spanning Adapter

1. Locate the following attaching parts for the wall

arm [three M8 hex nuts (60), three M8 lock
washers (50), and three M8 flat washers (40)].
See Figure 4.

2. With an assistant, perform the following steps:

a.

Lift wall arm onto the top wall-mounted 16”
stud-spanning adapter (10). See Figure 4.

b. Using the parts listed in step 1, attach the

wall arm to the top wall-mounted 16” stud-
spanning adapter (10). Tighten hex nuts.

Summary of Contents for Dual Stud Adapter CTA-111

Page 1: ... could affect or void the Factory warranty thoroughly study all instructions and illustrations before you begin to install the CTA 111 Pay particular attention to the Warnings and Cautions in this document If you have any questions about this installation contact Chief Manufacturing at 1 800 582 6480 or 952 582 6480 The CTA 111 Dual Stud Adapter provides a 16 on center mounting solution for the fo...

Page 2: ...orce the mounting surface structural members before installing the mount WARNING Be aware of the potential for personal injury or damage to the equipment if it is not adequately mounted WARNING The installer is responsible for verifying that the mounting surface to which the CTA 111 is anchored will safely support the combined load of all attached components or other equipment WARNING The combined...

Page 3: ...apter to Wall 6 Attaching Front Cover 6 Connecting NPT Pipe or Nipple to Wall Arm 6 INSPECT THE UNIT BEFORE INSTALLING Unpack the carton Carefully inspect the parts for shipping damage Verify contents listed in Table 1 If you are missing any of the listed parts contact Customer Service at 1 800 582 6480 300 Table 1 Shipping Contents ITEM DESCRIPTION QTY 10 16 Spanning Adapter 2 20 5 16 X 2 5 Lag B...

Page 4: ...hers 30 WARNING It is the installer s responsibility to verify that the structure to which the mount is anchored will safely support five times the combined load of all attached components and equipment 2 Determine a suitable mounting location Keep in mind that both stud spanning adapters 10 must be mounted to wood studs that are 16 apart on center 3 Using a stud sensor locate the two wood studs w...

Page 5: ...all arm and its attaching parts three M8 hex nuts 60 three M8 lock washers 50 and three M8 flat washers 40 See Figure 3 2 Using the parts listed in step 1 attach the wall arm to the bottom 16 stud spanning adapter 10 Tighten hex nuts See Figure 3 STEP 3 Attaching Wall Arm to Wall Mounted Top Stud Spanning Adapter 1 Locate the following attaching parts for the wall arm three M8 hex nuts 60 three M8...

Page 6: ... or both knockouts on cover to assist routing to wall through cover 2 Install the front cover using four M4 8mm Phillips head cap screws See Figure 6 STEP 6 REFERENCE ONLY Connecting NPT Pipe or Nipple to Wall Arm 1 Locate M6 x 6mm set screw and 1 1 2 NPT pipe or nipple supplied with TV Mount or purchased separately 2 Connect the 1 1 2 NPT pipe or nipple supplied with TV Mount or purchased separat...

Reviews: