Installation Instructions
MSP-CSH1
5
Assembly And Installation
Attach to Wall
NOTE:
The MSP-CSHI must be mounted to wood studs that
are 16" apart.
1.
Use stud finder to locate studs.
2.
Using CPU holder (A) as a template, mark and drill four 1/8"
holes in center of wood studs. (See Figure 1)
3.
Install four 1/4 x 2 1/2" hex head lag screws (K) through
CPU holder (A) and into drilled holes. (See Figure 1)
Figure 1
Install CPU
1.
Gently set CPU within CPU holder (A) with cables on same
side as cable management hole in CPU holder. (See Figure
2)
2.
Use 3/8" socket wrench to install two #10-24 x 1/2" carriage
screws (G) through CPU holder, CPU brackets (D) and into
#10-24 Nylock nuts (H). (See Figure 2)
Figure 2
3.
Place CPU cross strap (C) over CPU holder (A) lining up
holes with top center holes on CPU holder. (See Figure 3)
4.
Install two #10-24 x 1/4" button head cap screws (F) through
CPU cross strap (C) and CPU holder (A). (See Figure 3)
Figure 3
x 4
(K) x 4
3
2
(D) x 2
1
(G) x 2
(H) x 2
2
(C)
(F) x 2
4
3