PAC501
Installation Instructions
8
Figure 5
NOTE:
The PAC501 has 1/2" total clearance between the two
studs. The spacers allow side to side adjustment.
7.
Drill eight 3/16" diameter pilot holes in horizontal framing at
top and bottom mounting holes. (See Figure 6)
8.
Attach the PAC501 (A) to horizontal framing using eight
M7 x 40mm Allen head connector screws (C) using an M4
Allen head drill bit (E). (See Figure 6)
Figure 6
DANGER:
IMPROPER WIRING CAN LEAD TO DEATH
OR SEVERE PERSONAL INJURY! Grounding must be
installed by qualified personnel using a UL Recognized No.
12AWG Green and Yellow grounding wire connected to
grounding lug on mount.
Figure 7
Installing Arm Kit
Install arm kit following instructions included with the kit.
x
5
6
x 4
(D) x 4
(B) x 4
8
(C) x 8
7
x 8
Grounding Lug Locations