background image

8

Wire/Cable Management - Use “integrated zip-tie hook”

in back wall of box to organize and secure cables and

AV components. 

16

Install template as temporary cover if needed to protect

from debris by folding tabs in and inserting into opening. 

17

Gather wires and route through cover opening. Install 

cover, screw fasteners(2) into place to secure and 

complete enclosure. 

19

Secure box into 

place by methods 

chosen.

DRYWALL 

ATTACHMENT:

Slide locking 

cleats into place. 

Tighten screws 

to secure. 

STUD ATTACHMENT:

Drill pilot holes (optional) into studs through mounting 

holes in box. Wood studs - use 3/16” bit. If steel studs 

- use 1/4” bit. Install with 1/4 - 20 x 2 1/2” screws (E) 

into pilot holes.  

14

NOTE:

Box may be installed with outer flange removed 

for a pre-sheetrock open stud mount configuration.    

NOTE:

Save flange for 

reattachment after 

sheetrock is installed.

Plastic

Spacer

Mounting

Screw

Cover

15

PAC525/526 Final Finishing

Modify enclosure cover before attaching. Break away tab(s) 

to allow wire exit from box and meet ventilation needs. 

18

NOTE:

Locate front edge of box extended    

beyond studs by thickness of 

sheetrock to be used.

Installation Instructions

PAC525/526

Summary of Contents for PAC525

Page 1: ...In Wall Accessory Boxes I N S T A L L A T I O N I N S T R U C T I O N S PAC525 526 PAC525 PAC526 ...

Page 2: ...er s responsibility to make sure the structure to which this accessory is attached can support five times the combined weight of all equipment WARNING Exceeding the weight capacity can result in serious personal injury or damage to equipment It is the installer s responsibility to make sure the combined weight of all components located in the accessory does not exceed 10 lbs 4 5 kg WARNING Use thi...

Page 3: ...76 2 10 93 277 6 2 57 65 2 4 75 120 7 38 9 5 1 38 34 9 1 13 28 6 3 73 94 9 1 72 43 7 1 36 34 5 0 87 21 8 15 51 394 1 15 40 391 1 14X 75 X 25 ZIP TIE ANCHOR HOOKS 14 25 362 4 75 120 7 3 00 76 2 10 93 277 6 38 9 5 1 38 34 9 2 57 65 2 14 25 362 5 00 127 11 75 298 5 7 13 181 82 20 8 1 82 46 2 2 57 65 2 1 13 28 6 3 73 94 9 3 88 98 4 1 72 43 7 1 36 34 5 0 87 21 8 Installation Instructions PAC525 526 ...

Page 4: ...ns Phillips Screwdriver Destornillador Phillips Kreuzschlitzschraubendreher Chave de fendas Phillips Cacciavite a stella Kruiskopschroevendraaier Tournevis à pointe cruciforme Mark level line Flathead Screwdriver Pencil Mark Marcar con lápiz Stiftmarkierung Marcar com lápis Segno a matita Potloodmerkteken Marquage au crayon Drill Hole Perforar Bohrloch Fazer furo Praticare un foro Gat boren Percez...

Page 5: ...ectrical Outlet Steel Handy Box Cover Duplex Raco 864 or equiv Zip Ties A E F I H B C Template Temporary Cover Earthing symbol IEC 60418 No 5019 affixed adjacent to grounding terminal Grounding screw installed at factory D 1 2 3 4 5 2 Flathead 1 4 20 x 2 1 2 Screw 4x 6 32 x 3 8 Screw 8x G Security Hex Key 10 32 x 3 8 6 32 Hex Nut 8x J 6 x 1 1 2 Button Security Screw 3 8 Flat Washer 4x Items may va...

Page 6: ... free of electrical wires and cables before cutting drilling or installing fasteners WARNING EXPLOSION AND FIRE HAZARD CUTTING OR DRILLING INTO GAS PLUMBING CAN CAUSE DEATH OR SERIOUS PERSONAL INJURY ALWAYS make certain area behind mounting surfaces is free of gas water waste or any other plumbing before cutting drilling or installing fasteners Determine installation type Housing is designed to fi...

Page 7: ...drywall NOTE Cutting past corners weakens the cleats ability to hold securely 9 Remove knock outs in box as predetermined in step 5 PAC525 526 Box Preparation 10 Once wall opening is completed check stud depth If 3 5 or greater proceed to step 11 If less than 3 5 deep modify depth of box as follows before proceeding CAUTION Injury may occur on sharp edges Carefully discard the removable tabs A Rem...

Page 8: ...to secure STUD ATTACHMENT Drill pilot holes optional into studs through mounting holes in box Wood studs use 3 16 bit If steel studs use 1 4 bit Install with 1 4 20 x 2 1 2 screws E into pilot holes 14 NOTE Box may be installed with outer flange removed for a pre sheetrock open stud mount configuration NOTE Save flange for reattachment after sheetrock is installed Plastic Spacer Mounting Screw Cov...

Page 9: ......

Page 10: ......

Page 11: ......

Page 12: ...3 DK Weert Netherlands P 31 0 495 580 852 F 31 0 495 580 845 Asia Pacific A Office No 1 on 12 F Shatin Galleria 18 24 Shan Mei Street Fotan Shatin Hong Kong P 852 2145 4099 F 852 2145 4477 Chief a products division of Milestone AV Technologies 8800 002517 Rev00 2014 Milestone AV Technologies www chiefmfg com 03 14 Installation Instructions PAC525 526 ...