background image

CHIEF MANUFACTURING INC.  

 

 

         

8805-000141 (Rev. C) 

1-800-582-6480

  952-894-6280 FAX 952-894-6918        

©

 

2005 Chief Manufacturing 

8401 EAGLE CREEK PARKWAY, STE. 700                               

www.chiefmfg.com

 

SAVAGE, MINNESOTA 55378  USA                                                                 11/05

 

I N S T A L L A T I O N       I N S T R U C T I O N S  

PLP Series

 

Wall Mount 

 
The PLP Series wall mount accommodates large flat 
screens weighing up to 200 lbs (90.72kg). The teardrop 
holes in the mount allow for quick connect/disconnect of 
the screen, thus simplifying installation and maintenance 
processes.  

The top and bottom mounting brackets are adaptable to 
supporting framework with wood studs that are 16” on 
center or 24”on center.  

The mount has integrated lateral shift, allowing for four 
different mounting options. For dual wood studs 16” on 
center, the lateral shift is 

+

 4.5 inches. For dual wood 

studs 24” on center, the lateral shift is 

+

 0.5 inches. 

The display can be pulled and tilted by hand into any 
position in the zero-to-15 degree tilt range and remain 
stationary. 

The bottom of the mount pulls forward 3” from the wall 
and locks into place for installation of cable connections. 

The mount also uses Chief’s exclusive Q-Latch™ 
mounting system, which offers quick connect/disconnect 
display mounting. The display is secured to the mount 
with a latching flag. For additional security, you can lock 
the latching flag in place by adding a padlock. 
 
 
 

 

 

PLP Series 

 

! IMPORTANT:

  If the installation of this product requires OSHPD seismic

 

approval, refer to OSHPD    pre-approval 

documents and drawings before beginning installation. OSHPD documents and drawings are available at 

www.chiefmfg.com

, and located on the product information page for the mount. 

 
 

BEFORE YOU BEGIN  

 

 

CAUTION:  To prevent damage to your monitor and PLP, which could affect or void the Factory warranty, 
thoroughly study all instructions and illustrations before you begin to install the mount. Pay particular 
attention to the Warnings and Cautions in this document.

 

 

The mount is designed to be installed using wall studs or supporting framework. The fasteners used to anchor the 
mount must be capable of supporting five times the total weight of the equipment. 

 

The maximum weight to be installed on the PLP Series wall mount is 200 lbs (90.72kg). 

 

If you have any questions about this installation, contact Chief Manufacturing at 1-800-582-6480 or 952-582-6480. 

 
 

Summary of Contents for PLP Series

Page 1: ...llation of cable connections The mount also uses Chief s exclusive Q Latch mounting system which offers quick connect disconnect display mounting The display is secured to the mount with a latching flag For additional security you can lock the latching flag in place by adding a padlock PLP Series IMPORTANT If the installation of this product requires OSHPD seismic approval refer to OSHPD pre appro...

Page 2: ... injury or damage to the equipment if it is not installed correctly Consider the weight of the mount without the display WARNING The installer is responsible for verifying that the display to which the wall mount is fastened will safely support the combined load of all attached components or other equipment WARNING The combined weight of the display placed on the wall mount must not exceed 200 lbs...

Page 3: ...et Socket wrench set NOTE Other tools may be required depending on your method of installation Figure 1 PLP Parts PARTS LIST Prior to assembly unpack the carton completely Verify contents listed in Table 1 and Figure 1 Read installation instructions completely If you are missing any of the listed parts contact Customer Service at 1 800 582 6480 Table 1 Parts List REF DESCRIPTION QTY 10 PLP Series ...

Page 4: ...P as follows Refer to Figure 3 for wood studs that are 16 apart on center OR Refer to Figure 4 for wood studs that are 24 apart on center 3 Using a nail as a temporary hook hang the mount on the wall using the triangular hole located in the center of the mount see Figure 2 4 Use a pencil to mark the mounting holes where the four pilot holes will be drilled into the center of the wood stud Make sur...

Page 5: ...s centering the PLP on dual wood studs 16 apart on center as shown in Figure 5 OR Option B Install four 5 16 x 2 lag bolts and four 5 16 washers two top and two bottom into the mounting holes that are right of center on dual wood studs 16 apart as shown in Figure 6 OR Option C Install four 5 16 x 2 lag bolts and four 5 16 washers two top and two bottom into the mounting holes that are left of cent...

Page 6: ...ting to mount the display 1 With the aid of another person lift the display up to the mount on the wall aligning mounting buttons with the teardrop slots on the mount and lower the display firmly into place Figure 8 2 Raise the latching flag to secure the display see Figure 9 If the flag does not fully engage check to ensure the mounting buttons are fully seated in the slots NOTE A padlock may be ...

Page 7: ... the display 0 to 7 up into the service position see Figure 11 2 Lower center support bar to keep the display tilted up see Figure 12 3 Perform service For example Connect or disconnect the power audio video cables NOTE The service position is not recommended as a final display position 4 Raise the center support bar and reposition the display to desired position if necessary refer to TILT ADJUSTM...

Reviews: