background image

 PWRSKU

Installation Instructions

2

DISCLAIMER

Milestone AV Technologies, and its affiliated corporations and 
subsidiaries (collectively, "Milestone"), intend to make this 
manual accurate and complete. However, Milestone makes no 
claim that the information contained herein covers all details, 
conditions or variations, nor does it provide for every possible 
contingency in connection with the installation or use of this 
product. The information contained in this document is subject 
to change without notice or obligation of any kind. Milestone 
makes no representation of warranty, expressed or implied, 
regarding the information contained herein. Milestone assumes 
no responsibility for accuracy, completeness or sufficiency of 
the information contained in this document.
Chief® and ClickConnect™ are registered trademarks of 
Milestone AV Technologies. All rights reserved.

 IMPORTANT WARNINGS AND 

CAUTIONS!

WARNING:  

A WARNING alerts you to the possibility of 

serious injury or death if you do not follow the instructions.

CAUTION:  

A CAUTION alerts you to the possibility of 

damage or destruction of equipment if you do not follow the 

corresponding instructions.

WARNING:  

Failure to read, thoroughly understand, and 

follow all instructions can result in serious personal injury, 
damage to equipment, or voiding of factory warranty!  It is the 
installer’s responsibility to make sure all components are 
properly assembled and installed using the instructions 
provided.

WARNING:  

Failure to provide adequate structural strength 

for the installation of this kit can result in serious personal 
injury or damage to equipment!  It is the installer’s 
responsibility to make sure the structure to which this mount 
is attached can support five times the combined weight of all 
equipment.

WARNING:  

Exceeding the weight capacity can result in 

serious personal injury or damage to equipment!  It is the 
installer’s responsibility to make sure the combined weight of 
all components attached to this accessory does not exceed 
100lbs  (45.3 kg) if  being installed on a wall with a minimum 
1/2" thick drywall, or 125 lbs (56.7 kg) if  being installed on a 
wall with a minimum 5/8" thick drywall.

LEGEND

Tighten Fastener

Apretar elemento de fijación

Befestigungsteil festziehen

Apertar fixador

Serrare il fissaggio

Bevestiging vastdraaien

Serrez les fixations

Сожмите

 

Застежку

Loosen Fastener

Aflojar elemento de fijación

Befestigungsteil lösen

Desapertar fixador

Allentare il fissaggio

Bevestiging losdraaien

Desserrez les fixations

Ослабьте

 

Застежку

Open-Ended Wrench

Llave de boca

Gabelschlüssel

Chave de bocas

Chiave a punte aperte

Steeksleutel

Clé à fourche

Открытый

 

Рывок

Adjust

Ajustar

Einstellen

Ajustar

Regolare

Afstellen

Ajuster

Приспособьтесь

Phillips Screwdriver

Destornillador Phillips

Kreuzschlitzschraubendreher

Chave de fendas Phillips

Cacciavite a stella

Kruiskopschroevendraaier

Tournevis à pointe cruciforme

Отвертка

Hex-Head Wrench

Llave de cabeza hexagonal

Sechskantschlüssel

Chave de cabeça sextavada

Chiave esagonale

Zeskantsleutel

Clé à tête hexagonale

Главный

 

ведьмой

 

Рывок

Summary of Contents for PWRSKU

Page 1: ...es de Instalação Istruzioni di installazione Installatie instructies Instructions d installation Large Flat Panel Steel Stud Wall Mount Spanish Product Description German Product Description Portuguese Product Description Italian Product Description Dutch Product Description French Product Description PWRSKU ...

Page 2: ...structions provided WARNING Failure to provide adequate structural strength for the installation of this kit can result in serious personal injury or damage to equipment It is the installer s responsibility to make sure the structure to which this mount is attached can support five times the combined weight of all equipment WARNING Exceeding the weight capacity can result in serious personal injur...

Page 3: ...HE MOUNT SEE PSB XXXX DRAWING ALSO 3 93 100 533 21 00 62 279 10 99 27 00 686 635 25 00 432 17 00 25 1 00 302 11 90 493 19 40 228 8 96 2 43 4 74 120 INCHES THE FOLLOWING FORMAT Mounting Pattern ALL MEASUREMENTS ARE IN MILLIMETERS PRODUCT FEATURES WEIGHT CAPACITY 125 LBS HEIGHT ADJUSTMENT 0 TILT ROLL YAW 5 15 2 5 0 25 03 636 3 50 89 Extended Tilted Down Tilted Up Unit Depth Retracted Tilt Adjustment...

Page 4: ...PWRSKU Installation Instructions 4 TOGGLERĂ x1 I M 1 4 1 2 Ø13mm B 8 E 2 C 8 D 8 1 4 20 x 1 3 4 A 1 G 4 F 1 H 1 J 2 1 4 20 SNAPTOGGLE BB K 12 TOOLS REQUIRED FOR INSTALLATION AND PARTS ...

Page 5: ...uld be mounted to the same stud Figure 1 to a minimum of one stud left and right of the stud s Stud type and structural strength must conform to the North American Drywall 1 2 100 lbs max or Drywall Thickness Display Mount Installation Location FRONT Both Sides of Stud Must be centered on stud There must be a minimum of 1 7 8 48mm clearance inside wall 16 or 24 on center Studs If back side of wall...

Page 6: ...om wall until channel rests flush behind wall making sure anchor channel is positioned vertically on stud See Figure 4 8 Slide plastic cap on anchor D towards wall until flange of cap is flush with wall See Figure 4 Figure 4 9 Snap off plastic straps on anchor at wall by pushing side to side snapping off straps level with flange of plastic cap See Figure 5 10 Repeat steps 6 through 9 for each moun...

Page 7: ...nd positioning as shown in figure below See Figure 7 2 Lower bottom of upper wall channel cover E and tap firmly across bottom of channel to lock in place as shown in figure below See Figure 7 3 Install R H and L H end caps G by aligning tabs on end caps with slots in wall channel and sliding tabs into channel until end cap is flush with wall channel cover cover E 4 Repeat steps 4 through 6 above ...

Page 8: ... engaged See Figure 8 and See Figure 9 Figure 8 NOTE Holes are provided in the faceplate for use with a padlock or similar locking device if desired In addition the pin and nut may be removed from the upper holes and moved to the lower holes for use as a more permanent locking device See Figure 9 Figure 9 CABLE MANAGEMENT WARNING IMPROPER INSTALLATION CAN LEAD TO SERIOUS PERSONAL INJURY OR DAMAGE ...

Page 9: ...ntal alignment Roll of the display to be adjusted up to 2 deg right or left to level the display after installing To adjust Roll 1 Loosen the roll tension adjustment nut located on the back side of the faceplate assembly See Figure 11 2 Level display 3 Tighten roll tension adjustment nut See Figure 11 Figure 11 2 1 3 ...

Page 10: ...ee Figure 12 NOTE The display may need to be repositioned in order to gain access to the tension adjustment screw s 3 Check swing arm tension If desired tension is present tension adjustment is complete If additional tension adjustment is required repeat steps 2 thru 4 until desired tension is achieved NOTE If changing from a smaller display to a larger display may be necessary to increase swing a...

Page 11: ...Installation Instructions PWRSKU 11 ...

Page 12: ...e A Fellenoord 130 5611 ZB EINDHOVEN The Netherlands P 31 0 40 2668620 F 31 0 40 2668615 Asia Pacific A Room 24F Block D Lily YinDu International Building LuoGang BuJi Town Shenzhen CHINA P 86 755 8996 9226 F 86 755 8996 9217 Chief Manufacturing a division of Milestone AV Technologies 8832 000224 RevD 2008 Milestone AV Technologies www chiefmfg com 08 08 ...

Reviews: