RSME
Installation Instructions
6
CPA Adapter Removal
NOTE:
If installing RSME to anything other than a
CPA column, the CPA adapter portion must be
removed from RSME mount prior to
installation.
1.
Loosen set screw holding CPA adapter to RSME
mount.
2.
Turn CPA adapter counter-clockwise until threads
are no longer engaged with RSME.
3.
Remove CPA adapter from RSME.
RSME INSTALLATION
CPA Pipe Installation
1.
Carefully determine required mounting location.
IMPORTANT ! :
This will require knowing the
lens to screen distance. See projector
specifications for details on determining this
distance.
2.
Making sure holes are aligned on RSME’s CPA
adapter and CPA column (not included), lift RSME
into bottom opening of CPA column.
3.
Install either one M6x16 button head screw (C) or
security screw (D) into hole on side of CPA pipe
where the adapter plate on CPA adapter is located.
4.
On the opposite side of CPA pipe, use the other
M6x16 button head screw (C) or security screw (D)
to secure RSME (A) to CPA column.
5.
Tighten security screw (access from bottom of
RSME) using a Phillips screwdriver until set screw
cannot be seen through set screw access hole in
RSME.
6.
Proceed to "Projector Installation" Section.
1a
1
2
3
1
CPA adapter
3
2
CMA pipe
(not included)
4
(C) or (D)
(C) or (D)
CPA adapter
5
adapter
plate
hole on side
of adapter plate