background image

TA500

Installation Instructions

Chief Manufacturing, a products division
of Milestone AV Technologies

8800-002234 Rev02

2013 Milestone AV Technologies,

a Duchossois Group Company

www.chiefmfg.com

06/13

USA/International

A

6436 City West Parkway, Eden Prairie, MN 55344

P

800.582.6480 / 952.225.6000

F

877.894.6918 / 952.894.6918

Europe

A

Franklinstraat 14, 6003 DK Weert, Netherlands

P

+31 (0) 495 580 852

F

+31 (0) 495 580 845

Asia Pacific

A

Office No. 1 on 12/F, Shatin Galleria
18-24 Shan Mei Street

Fotan, Shatin, Hong Kong

P

852 2145 4099

F

852 2145 4477

Summary of Contents for Thinstall TA500

Page 1: ... I N S T R U C T I O N S THINSTALL IN WALL ENCLOSURE Spanish Product Description German Product Description Portuguese Product Description Italian Product Description Dutch Product Description French Product Description TA500 ...

Page 2: ...equipment It is the installer s responsibility to make sure the structure to which this component is attached can support five times the combined weight of all equipment Reinforce the structure as required before installing the component The wall to which the mount is being attached may have a maximum drywall thickness of 5 8 1 6cm WARNING Exceeding the weight capacity can result in serious person...

Page 3: ...saggio Bevestiging losdraaien Desserrez les fixations Phillips Screwdriver Destornillador Phillips Kreuzschlitzschraubendreher Chave de fendas Phillips Cacciavite a stella Kruiskopschroevendraaier Tournevis à pointe cruciforme Pencil Mark Marcar con lápiz Stiftmarkierung Marcar com lápis Segno a matita Potloodmerkteken Marquage au crayon Drill Hole Perforar Bohrloch Fazer furo Praticare un foro Ga...

Page 4: ... Extras if needed for installing electrical box F 1 M4 Allen driver bit G 4 2 long 2 short Trim pieces K 16 Tape squares H 4 Cable tie mounts J 12 5 1 2 cable tie L 4 9 16 Grounding screw and washer installed at factory Earthing symbol IEC 60417 No 5019 affixed adjacent to grounding terminal A 1 TA500 M 12 5 16 18 X 1 2 N 4 Attach bracket ...

Page 5: ...ake certain area behind mounting surfaces is free of electrical wires and cables before cutting drilling or installing fasteners WARNING EXPLOSION AND FIRE HAZARD CUTTING OR DRILLING INTO GAS PLUMBING CAN CAUSE DEATH OR SERIOUS PERSONAL INJURY ALWAYS make certain area behind mounting surfaces is free of gas water waste or any other plumbing before cutting drilling or installing fasteners 2 Remove ...

Page 6: ...secure to wood studs See Figure 2 Figure 2 NOTE Ensure screws are far enough from block end to prevent interference with framing screws installed in In Wall Enclosure Installation section 10 If necessary cut rectangular hole in horizontal framing to accommodate the PAC GB1 Listed electrical box accessory not included In Wall Enclosure Installation 1 Install PAC GB1 Listed electrical box accessory ...

Page 7: ... OR SEVERE PERSONAL INJURY Grounding must be installed by qualified personnel using a UL Recognized No 12AWG grounding wire connected to grounding lug on mount Figure 6 TS325TU TS525TU Installation IMPORTANT The TA500 was designed specifically for the TS325TU or TS525TU wall mount Do not attempt to install any other wall mounts with the TA500 1 Use eight 5 16 18 x 1 2 button head cap screws M to a...

Page 8: ... 9 4 Tighten two screws M to secure upper wall plate to upper attachment brackets 5 Slide TS325TU TS525TU assembly onto upper wall plate of TS325TU TS525TU See Figure 10 Figure 10 6 Use two 5 16 18 x 1 2 button head cap screws M to loosely attach lower wall plate of TS325TU TS525TU assembly to lower attachment brackets N See Figure 11 IMPORTANT Install to lower bracket holes for TS525TU and upper ...

Page 9: ...igure 12 Figure 12 12 Complete TS325TU TS525TU installation following TS325TU TS525TU installation instructions Trim Kit Optional 1 Remove paper covering adhesive and affix three tape squares K to inside lower flange of each trim piece G See Figure 13 2 Orient trim pieces G See Figure 13 3 Remove paper covering adhesive back from tape squares K on trim and press trim G against inner wall of box Se...

Page 10: ...TA500 Installation Instructions 10 ...

Page 11: ...Installation Instructions TA500 11 ...

Page 12: ...Company www chiefmfg com 06 13 USA International A 6436 City West Parkway Eden Prairie MN 55344 P 800 582 6480 952 225 6000 F 877 894 6918 952 894 6918 Europe A Franklinstraat 14 6003 DK Weert Netherlands P 31 0 495 580 852 F 31 0 495 580 845 Asia Pacific A Office No 1 on 12 F Shatin Galleria 18 24 Shan Mei Street Fotan Shatin Hong Kong P 852 2145 4099 F 852 2145 4477 ...

Reviews: