DISCLAIMER

Milestone AV Technologies, and its affiliated corporations and 
subsidiaries (collectively, "Milestone"), intend to make this 
manual accurate and complete. However, Milestone makes no 
claim that the information contained herein covers all details, 
conditions or variations, nor does it provide for every possible 
contingency in connection with the installation or use of this 
product. The information contained in this document is subject 
to change without notice or obligation of any kind. Milestone 
makes no representation of warranty, expressed or implied, 
regarding the information contained herein. Milestone assumes 
no responsibility for accuracy, completeness or sufficiency of 
the information contained in this document.
Chief® is a trademark of Milestone AV Technologies. 
All rights reserved.

 IMPORTANT SAFETY INSTRUCTIONS!

WARNING:  

A WARNING alerts you to the possibility of 

serious injury or death if you do not follow the instructions.

CAUTION:  

A CAUTION alerts you to the possibility of 

damage or destruction of equipment if you do not follow the 
corresponding instructions.

WARNING:  

Failure to read, thoroughly understand, and 

follow all instructions can result in serious personal injury, 
damage to equipment, or voiding of factory warranty!  It is the 
installer’s responsibility to make sure all components are 
properly assembled and installed using the instructions 
provided.

WARNING:  

Failure to provide adequate structural strength 

for this component can result in serious personal injury or 
damage to equipment!  It is the installer’s responsibility to 
make sure the structure to which this component is attached 
can support five times the combined weight of all equipment.  
Reinforce the structure as required before installing the 
component. The wall to which the mount is being attached 
may have a maximum drywall thickness of 5/8" (1.6cm).

WARNING:  

Exceeding the weight capacity can result in 

serious personal injury or damage to equipment!  It is the 
installer’s responsibility to make sure the structure to which 
this accessory is attached can support the combined weight 
of the box and all equipment not to exceed 75 lbs (34.0 kg). 
The combined weight of all components attached to the 
TS118SU mount cannot exceed 35 lbs (15.9 kg). The 
combined weight of all components attached to the TS218SU 
mount cannot exceed 75 lbs (34.0 kg). 

WARNING:  

Use this mounting system only for its intended 

use as described in these instructions. Do not use 
attachments not recommended by the manufacturer.

WARNING:  

Never operate this mounting system if it is 

damaged. Return the mounting system to a service center for 
examination and repair.

WARNING:  

Do not use this product outdoors.

NOTES: 

It is the installer’s responsibility to ensure that the 
enclosure is bonded to the ground in the switch box, 
in accordance with the National Electric Code, 
ANSI/NFPA 70 or Canadian Electrical Code, CSA 
C22.1. A green grounding screw is provided in the 
enclosure for the purpose, if required.

The equipment shall be installed and assembled by 
qualified service personnel.

Spacings - To ensure safe operation of the 
equipment installed in the enclosure, per National 
Electric Code ANSI/NFPA 70, a minimum separation 
between power cords and signal or communication 
cables may be required.

This Cabinet System is for use with Listed wall 
mounts. Refer to the individual mounts’ installation 
instructions for compatibility.

--SAVE THESE INSTRUCTIONS--

Summary of Contents for Thinstall TA502

Page 1: ...U C T I O N S WITH TS118 WITH TS218 THINSTALL IN WALL ENCLOSURE Spanish Product Description German Product Description Portuguese Product Description Italian Product Description Dutch Product Description French Product Description TA502 ...

Page 2: ...to which this component is attached can support five times the combined weight of all equipment Reinforce the structure as required before installing the component The wall to which the mount is being attached may have a maximum drywall thickness of 5 8 1 6cm WARNING Exceeding the weight capacity can result in serious personal injury or damage to equipment It is the installer s responsibility to m...

Page 3: ...LL BOX WITH TS218 FULLY RETRACTED MONITOR WILL BE FLUSH WITH WALL FULLY EXTENDED MONITOR WILL BE 16 55 FROM WALL MAX TILT IS 12 DEGREES 18 85 478 8 GROUNDING GROUNDING TRIM NOT SHOWN USE THESE DIMENSIONS FOR CUTOUT NOTES ELECTRICAL KNOCK OUTS 1 SINGLE GANG RACO 590 STEEL CITY CY 1 2 OR SIMILAR STYLE ELECTRICAL BOX 1 AND 2 TRADE PIPE CONDUIT PRODUCT WORKS WITH TS118 AND TS218 2 DIMENSIONS INCHES MI...

Page 4: ... ARM SMALL BOX WITH TS118 FULLY RETRACTED MONITOR WILL BE FLUSH WITH WALL FULLY EXTENDED MONITOR WILL BE 16 55 FROM WALL MAX TILT IS 12 DEGREES 14 25 362 0 SWING ARM SMALL BOX WITH TS218 FULLY RETRACTED MONITOR WILL BE FLUSH WITH WALL FULLY EXTENDED MONITOR WILL BE 16 55 FROM WALL MAX TILT IS 12 DEGREES ...

Page 5: ...esserrez les fixations Phillips Screwdriver Destornillador Phillips Kreuzschlitzschraubendreher Chave de fendas Phillips Cacciavite a stella Kruiskopschroevendraaier Tournevis à pointe cruciforme Pencil Mark Marcar con lápiz Stiftmarkierung Marcar com lápis Segno a matita Potloodmerkteken Marquage au crayon Drill Hole Perforar Bohrloch Fazer furo Praticare un foro Gat boren Percez un trou Hex Head...

Page 6: ...if needed for installing electrical box F 1 M4 Allen driver bit G 4 2 long 2 short Trim pieces K 16 Tape squares H 4 Cable tie mounts J 12 5 1 2 cable tie L 4 9 16 Grounding screw and washer installed at factory Earthing symbol IEC 60417 No 5019 affixed adjacent to grounding terminal A 1 TA502 M 4 5 16 18 x 1 2 N 3 1 4 20 x 1 2 P 1 attach bracket ...

Page 7: ... cutting drilling or installing fasteners 2 Using a stud sensor locate and mark studs 3 Center and level housing between marked studs 4 Using housing as a template draw pencil line completely around housing NOTE Housing is designed to fit between and directly against two adjacent wall studs See Figure 1 5 Cut drywall on outside edge of line and remove Frame Housing IMPORTANT Consult a qualified bu...

Page 8: ...ll four 3 16 diameter pilot holes in studs at side mounting holes See Figure 3 7 Attach the TA502 A using four M7 x 50mm Allen head connector screws D and four spacers B into pilot holes using an M4 Allen head drill bit F See Figure 4 NOTE The TA502 has 1 2 total clearance between the two studs The spacers allow side to side adjustment Figure 4 8 Drill four 3 16 diameter pilot holes in horizontal ...

Page 9: ...esponding hole on attach bracket P leaving screw hanging out 1 4 from bracket See Figure or See Figure 9 3 Hang TS118 218SU mount onto screw by latching key shaped hole over screw See Figure or See Figure 9 Figure 8 Figure 9 4 Use one TS118SU or two TS218SU 1 4 20 x 1 2 button head cap screws N to attach TS118 218SU to attach bracket P See Figure 10 and See Figure 11 5 Tighten all screws to secure...

Page 10: ...lange of each trim piece G See Figure 12 2 Orient trim pieces G See Figure 12 3 Remove paper covering adhesive back from tape squares K on trim and press trim G against inner wall of box See Figure 12 Figure 12 Cable Management 1 Attach all cables to display 2 If necessary use cable tie mounts H and cable ties J to secure cables within TA502 TS218SU N x 2 4 5 TS218SU install G x 4 3 K x 16 1 TS118...

Page 11: ...Installation Instructions TA502 11 ...

Page 12: ...com 10 15 USA International A 6436 City West Parkway Eden Prairie MN 55344 P 800 582 6480 952 225 6000 F 877 894 6918 952 894 6918 Europe A Franklinstraat 14 6003 DK Weert Netherlands P 31 0 495 580 852 F 31 0 495 580 845 Asia Pacific A Office No 918 on 9 F Shatin Galleria 18 24 Shan Mei Street Fotan Shatin Hong Kong P 852 2145 4099 F 852 2145 4477 ...

Reviews: