GD CHIGO HEATING & VENTILATION EQUIPMENT CO., LTD.

 

New CMV System - 4-Way Cassette Indoor Unit 

9

 

Electrical characteristics 

 

Model 

Indoor unit 

MFC 

Power cable 

Signal cable 

Hz 

Voltage 

Minimum 

Maximum 

L ≤ 20m 

L ≤ 50m 

Grounded 

CMV-V56Q/HR1-C 

50Hz 

220-240V 

198 

264

 

15 

2*2.5mm

2

 

2*4.0mm

2

 

2.5mm

2

 

2*0.75 mm

2

 

CMV-V71Q/HR1-C 

50Hz 

220-240V 

198 

264

 

15 

2*2.5mm

2

 

2*4.0mm

2

 

2.5mm

2

 

2*0.75 mm

2

 

CMV-V80Q/HR1-C 

50Hz 

220-240V 

198 

264

 

15 

2*2.5mm

2

 

2*4.0mm

2

 

2.5mm

2

 

2*0.75 mm

2

 

CMV-V90Q/HR1-C 

50Hz 

220-240V 

198 

264

 

15 

2*2.5mm

2

 

2*4.0mm

2

 

2.5mm

2

 

2*0.75 mm

2

 

CMV-V100Q/HR1-C 

50Hz 

220-240V 

198 

264

 

15 

2*2.5mm

2

 

2*4.0mm

2

 

2.5mm

2

 

2*0.75 mm

2

 

CMV-V112Q/HR1-C 

50Hz 

220-240V 

198 

264

 

15 

2*2.5mm

2

 

2*4.0mm

2

 

2.5mm

2

 

2*0.75 mm

2

 

CMV-V125Q/HR1-C 

50Hz 

220-240V 

198 

264

 

15 

2*2.5mm

2

 

2*4.0mm

2

 

2.5mm

2

 

2*0.75 mm

2

 

CMV-V140Q/HR1-C 

50Hz 

220-240V 

198 

264

 

15 

2*2.5mm

2

 

2*4.0mm

2

 

2.5mm

2

 

2*0.75 mm

2

 

CMV-V160Q/HR1-C 

50Hz 

220-240V 

198 

264

 

15 

2*2.5mm

2

 

2*4.0mm

2

 

2.5mm

2

 

2*0.75 mm

2

 

 

Notes:   

1)

 

Minimum: Permitted minimum operating voltage, lower than this value may damage the system 

2)

 

Maximum: Permitted maximum operating voltage, higher than this value may damage the system 

3)

 

MC: Minimum Current (A) 

4)

 

MFC: Maximum Fuse Current (A) 

5)

 

L: Total length of cable (m) 

Summary of Contents for CMV-D100Q/HR1-C

Page 1: ...Technical Support Division 2017 4 25 GD CHIGO HEATING VENTILATION EQUIPMENT CO LTD ...

Page 2: ...MV System 4 Way Cassette Indoor Unit 1 External appearance 2 Nomenclature 3 Specifications 4 Dimensions 5 Service space 6 Piping diagram 7 Wiring diagram 8 Capacity tables 9 Electric characteristics 10 Sound pressure levels 11 Accessories 12 Exploded view ...

Page 3: ...on Capacity 100W Chigo VRF system D 140 Q H R1 C DC Fan Motor Chigo VRF system Indoor unit code Q 4 w ay cassette G W al l m ounted TA Low ESP ducted TB M edi um ESP ducted TH H i gh ESP ducted LD Fl oor cei l i ng TF Ful lfresh ai r processor N Refrigerant type R 1 R 410A Power code N 208 230V 1PH 60H z O m i t 220 240V 1PH 50H z Function code H H eat pum p ...

Page 4: ... 1030 105 1030 1030 105 1030 1030 105 1030 Net Gross weight kg 5 4 8 5 4 8 5 4 8 Refrigerant type R410A R410A R410A Throttle type Electrical expansion valve Electrical expansion valve Electrical expansion valve Design pressure MPa 3 8 3 8 3 8 Liquid pipe Gas pipe mm Ø6 35 Ø12 7 Ø9 53 Ø15 9 Ø9 53 Ø15 9 Connecting wire Power wire AWG 16 16 16 Signal wire AWG 22 22 22 Drainage water pipe Outer diamet...

Page 5: ...05 1030 1030 105 1030 1030 105 1030 Net Gross weight kg 5 4 8 5 4 8 5 4 8 Refrigerant type R410A R410A R410A Throttle type Electrical expansion valve Electrical expansion valve Electrical expansion valve Design pressure MPa 3 8 3 8 3 8 Liquid pipe Gas pipe mm Ø9 53 Ø15 9 Ø9 53 Ø15 9 Ø9 53 Ø15 9 Connecting wire Power wire AWG 16 16 16 Signal wire AWG 22 22 22 Drainage water pipe Outer diameter mm Ø...

Page 6: ...030 1030 105 1030 1030 105 1030 Net Gross weight kg 5 4 8 5 4 8 5 4 8 Refrigerant type R410A R410A R410A Throttle type Electrical expansion valve Electrical expansion valve Electrical expansion valve Design pressure MPa 3 8 3 8 3 8 Liquid pipe Gas pipe mm Ø9 53 Ø15 9 Ø9 53 Ø15 9 Ø9 53 Ø15 9 Connecting wire Power wire AWG 16 16 16 Signal wire AWG 22 22 22 Drainage water pipe Outer diameter mm Ø25 Ø...

Page 7: ...1 950 950 50 CMV D71Q HR1 C 900 833 232 776 684 91 950 950 50 CMV D80Q HR1 C 900 833 232 776 684 91 950 950 50 CMV D90Q HR1 C 900 833 286 776 684 150 950 950 50 CMV D100Q HR1 C 900 833 286 776 684 150 950 950 50 CMV D112Q HR1 C 900 833 286 776 684 150 950 950 50 CMV D125Q HR1 C 900 833 286 776 684 150 950 950 50 CMV D140Q HR1 C 900 833 286 776 684 150 950 950 50 CMV D160Q HR1 C 900 833 286 776 684...

Page 8: ...ng pipe and drainpipe could be extracted out easily There is no direct radiation from heaters If the temperature and humidity of the ceiling exceeds respectively 30 and RH80 please stick insulating material on the body of the air conditioner Please use glass wool or expanded polyethylene etc which is more than 10 mm thick If it is more than 10 mm please collect it in the opening of the ceiling Ind...

Page 9: ...te Indoor Unit 6 Piping diagram Flare nut Liquid side Flare nut Liquid side Motor EXV T2 T1 T2B Heat exchanger Notes 1 T1 Room temperature sensor 2 T2 Temperature sensor of middle heat exchanger 3 T2B Temperature sensor of heat exchanger outlet 4 EXV Electrical expansion valve ...

Page 10: ...OR Orange BK Black BR Brown WH White 2 T1 Room temperature sensor 3 T2 Temperature sensor of middle heat exchanger 4 T2B Temperature sensor of heat exchanger outlet 5 EXV Electrical expansion valve 6 Electrical heater is optional please contact to Chigo s technician for the detail 7 Wiring diagram 7 1 Wiring diagram ...

Page 11: ...tte Indoor Unit Chigo VRF indoor unit connect with card key Connect the remote control terminal on the indoor PCB to the hotel card module NOTE The terminal in the hotel card module must be a switch without any voltage current input to the PCB otherwise the PCB will be broken ...

Page 12: ...0 11 2 12 0 12 5 14 0 15 0 16 0 Code 6 7 8 9 9 7 2 2 SW3 Name Switch number 1 of SW3 Switch number 4 of SW3 Switch number 2 3 of SW3 Function Auto restart when power failure switch ON OFF status operation mode fan speed temperature swing remote control locked will be recovered Indoor unit address elimination Reserved Setting ON DP 1 2 3 4 Dial up to disable Auto restart function ON DP 1 2 3 4 ON D...

Page 13: ... Name Switch number 3 4 of SW2 Function Heating temperature compensation value selection When temperature difference between setting temperature and room temperature is higher than the setting value indoor fan motor turns off DO NOT change the default setting without professional guidance Setting 1 2 3 4 5 6 7 8 6 C Default setting 1 2 3 4 5 6 7 8 2 C 1 2 3 4 5 6 7 8 4 C 1 2 3 4 5 6 7 8 8 C ON OFF...

Page 14: ...n of turning off fan motor in anti cold wind blow mode When indoor heat exchanger temperature is lower than the setting value indoor fan motor turns off DO NOT change the default setting without professional guidance Setting 1 2 3 4 5 6 7 8 15 C Default setting 1 2 3 4 5 6 7 8 20 C 1 2 3 4 5 6 7 8 24 C 1 2 3 4 5 6 7 8 26 C ON OFF ON OFF ON OFF ON OFF ...

Page 15: ...ent is 0 indoor fan motor turns off for 4 minutes this stopping duration time can be changed by below setting After that indoor fan will run in low speed for 1 minute this timing is fixed if indoor unit capacity requirement is still 0 then indoor fan motor keeps off for 4 minutes and then cycles DO NOT change the default setting without professional guidance Setting 1 2 3 4 5 6 7 8 4 minutes Defau...

Page 16: ... Cassette Indoor Unit 7 2 4 Dial up SW8 Dialing function of SW8 is temporarily retained so it is not defined temporarily It was dialed to the digital side before leaving factory Notes Dialing function of SW8 is used for debugging and it is commonly dialed to digital side ...

Page 17: ...9 5 21 7 10 5 21 7 73 5 55 7 91 5 37 8 15 4 78 23 4 92 4 44 5 80 4 63 6 69 5 21 7 10 5 21 7 73 5 55 7 83 5 32 8 07 4 73 25 4 92 4 44 5 80 4 63 6 69 5 21 7 10 5 21 7 73 5 50 7 76 5 27 7 99 4 69 27 4 92 4 44 5 80 4 63 6 69 5 21 7 10 5 21 7 66 5 44 7 68 5 22 7 92 4 64 29 4 92 4 44 5 80 4 63 6 69 5 21 7 10 5 21 7 58 5 39 7 61 5 17 7 84 4 60 31 4 92 4 44 5 80 4 63 6 69 5 21 7 10 5 21 7 51 5 34 7 54 5 1...

Page 18: ...53 9 42 7 34 10 00 7 34 10 89 7 81 11 03 7 50 11 37 6 67 25 6 92 6 25 8 17 6 53 9 42 7 34 10 00 7 34 10 89 7 74 10 92 7 43 11 26 6 61 27 6 92 6 25 8 17 6 53 9 42 7 34 10 00 7 34 10 79 7 67 10 82 7 36 11 15 6 54 29 6 92 6 25 8 17 6 53 9 42 7 34 10 00 7 34 10 68 7 59 10 72 7 29 11 04 6 48 31 6 92 6 25 8 17 6 53 9 42 7 34 10 00 7 34 10 58 7 52 10 62 7 22 10 94 6 42 33 6 92 6 25 8 17 6 53 9 42 7 34 10...

Page 19: ...91 9 34 25 9 69 8 75 11 44 9 14 13 19 10 28 14 00 10 28 15 24 10 84 15 29 10 40 15 76 9 25 27 9 69 8 75 11 44 9 14 13 19 10 28 14 00 10 28 15 10 10 73 15 15 10 30 15 61 9 16 29 9 69 8 75 11 44 9 14 13 19 10 28 14 00 10 28 14 96 10 63 15 01 10 20 15 46 9 07 31 9 69 8 75 11 44 9 14 13 19 10 28 14 00 10 28 14 82 10 53 14 86 10 10 15 31 8 98 33 9 69 8 75 11 44 9 14 13 19 10 28 14 00 10 28 14 67 10 33 ...

Page 20: ...04 5 04 5 04 15 14 7 5 20 5 20 5 20 5 20 5 20 5 20 13 12 6 5 36 5 36 5 36 5 36 5 36 5 36 11 10 5 5 60 5 60 5 60 5 60 5 60 5 60 10 9 5 5 84 5 84 5 84 5 84 5 84 5 84 9 1 8 5 6 00 6 00 6 00 6 00 6 00 6 00 7 6 7 6 08 6 08 6 08 6 08 6 08 6 08 5 6 5 6 32 6 32 6 32 6 32 6 32 6 32 3 7 3 6 64 6 64 6 64 6 64 6 64 6 64 0 7 0 7 12 7 12 7 12 7 12 7 12 6 72 2 2 3 7 52 7 52 7 52 7 52 7 36 6 72 4 1 5 7 76 7 76 7 ...

Page 21: ... 15 7 15 13 12 6 7 37 7 37 7 37 7 37 7 37 7 37 11 10 5 7 70 7 70 7 70 7 70 7 70 7 70 10 9 5 8 03 8 03 8 03 8 03 8 03 8 03 9 1 8 5 8 25 8 25 8 25 8 25 8 25 8 25 7 6 7 8 36 8 36 8 36 8 36 8 36 8 36 5 6 5 8 69 8 69 8 69 8 69 8 69 8 69 3 7 3 9 13 9 13 9 13 9 13 9 13 9 13 0 7 0 9 79 9 79 9 79 9 79 9 79 9 24 2 2 3 10 34 10 34 10 34 10 34 10 12 9 24 4 1 5 10 67 10 67 10 67 10 67 10 12 9 24 6 7 11 00 11 0...

Page 22: ...40 10 40 10 40 10 40 10 40 10 40 11 10 5 10 90 10 90 10 90 10 90 10 90 10 90 10 9 5 11 30 11 30 11 30 11 30 11 30 11 30 9 1 8 5 11 60 11 60 11 60 11 60 11 60 11 60 7 6 7 11 80 11 80 11 80 11 80 11 80 11 80 5 6 5 12 30 12 30 12 30 12 30 12 30 12 30 3 7 3 12 90 12 90 12 90 12 90 12 90 12 90 0 7 0 13 80 13 80 13 80 13 80 13 80 13 00 2 2 3 14 60 14 60 14 60 14 60 14 30 13 00 4 1 5 15 00 15 00 15 00 15...

Page 23: ... 2 5mm2 2 4 0mm2 2 5mm2 2 0 75 mm2 CMV V100Q HR1 C 50Hz 220 240V 198 264 15 2 2 5mm2 2 4 0mm2 2 5mm2 2 0 75 mm2 CMV V112Q HR1 C 50Hz 220 240V 198 264 15 2 2 5mm2 2 4 0mm2 2 5mm2 2 0 75 mm2 CMV V125Q HR1 C 50Hz 220 240V 198 264 15 2 2 5mm2 2 4 0mm2 2 5mm2 2 0 75 mm2 CMV V140Q HR1 C 50Hz 220 240V 198 264 15 2 2 5mm2 2 4 0mm2 2 5mm2 2 0 75 mm2 CMV V160Q HR1 C 50Hz 220 240V 198 264 15 2 2 5mm2 2 4 0mm...

Page 24: ... Sound pressure level Model Sound pressure level dB A High speed Medium speed Low speed CMV D56Q HR1 C 39 37 35 CMV D71Q HR1 C 39 38 36 CMV D80Q HR1 C 41 39 37 CMV D90Q HR1 C 41 39 37 CMV D100Q HR1 C 41 39 37 CMV D112Q HR1 C 41 39 37 CMV D125Q HR1 C 41 39 37 CMV D140Q HR1 C 41 39 37 CMV D160Q HR1 C 41 39 37 Notes During actual operation these values are normally somewhat higher as a result of ambi...

Page 25: ...olling indoor unit Batteries 2 Power to remote controller EXV connection pipe 1 Connecting with EXV box and indoor unit liquid pipe Nuts gaskets 4 For hanging indoor unit Circlips 2 For fixing drainage pipe Drainage connection pipe 1 For connecting draining condensate water pipe to indoor unit Expandable screw 4 Used to hang the air conditioner Bag 4 For bagging accessories 11 2 Local buy accessor...

Page 26: ...25 GD CHIGO HEATING VENTILATION EQUIPMENT CO LTD New CMV System 4 Way Cassette Indoor Unit 12 Exploded view ...

Page 27: ...is for E parts box 1 11 3 Liquid level sensor 1 3 Wind inlet guide assy 1 11 4 Underlay for water pump support 3 3 1 Wind inlet guide 1 12 Hanger 4 4 Water pan components 1 13 Rear brattice 1 4 1 Foam pendant 2 14 Chassis assy 1 5 Centrifugal fan 1 15 Discharge pipe joint 1 6 Fan motor for indoor unit YDK 75Q 6P3 2 1 16 Side maintenance board for water pump 1 7 Auxiliary fixing board for evaporato...

Reviews: