5

 

別売リモートケーブルについて 

Remote Cable (Sold Separately)

 

5.1 

電気回路図 

Electrical circuit diagram 

 
 
 
 
 
 
 
 
 
 
 
 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

リモート運転 

Remote operation switch 

リモートモード移行 
(ON 時に遠隔操作可能、この時パネル操作は不可) 

Shifting to remote mode 
(Remote control is possible in the ON, and the panel 
is impossible to control at this time.)

 

 

 

②圧力アナログ信号      出力  ≧4.7kΩ    ※温度補正なし 

Pressure 

analog output

  : 

Output 

impedance 4.7kΩ 

Temperature correction is not provided.

 

参照例

Reference

 

example 

インダクター(リレー等)を付加する場合は出力端子

(端子番号 3・5・6)にノイズリミッター(約 33Ω+0.1

μF)を付けて下さい 

Attach a  noise limiter (Approximately 33Ω+0.1μ

F)  to the output terminals(Nos.1.2 and 3) 

When adding inductors(such as relays) 

インダクタ(リレー等を付加する場合は、ノイズリミッター 

(約 33Ω+0.1μF)又は、ダイオード等を付けて下さい。 

 

 

 

 

 

 

LOAD 

LOAD 

+

 

1

2

3

5

6

8

LOAD

LOAD

LOAD

圧力不足信号

DC 1~5V

耐圧 DC 50V

100mmA以下

DC 0~5V

運転信号

Operation output signal

運転入力信号

Operation input signal

遠隔操作切替信号

Remote-control operation

switching signal

運転圧力信号

Operation pressure signal

風量不足信号

Air flow shortage signal

Insufficient pressure signal

GND

7

GND

能力レベル変更入力信号

Ability level change input signal

Summary of Contents for CBA-1000AT2-HC-DSA-V1

Page 1: ...arker is an energy saving type clean box that realizes air technology in a compact body Please read this instruction manual thoroughly and handle this machine correctly so that you can use it safely f...

Page 2: ...osene paint etc Explosive dust Aluminum magnesium titanium zinc epoxy etc Dust containing sparks Dust containing sparks generated by high speed cutters grinders welding machines etc Fire sources Cigar...

Page 3: ...AT panel 9 4 3 Remote connector 12 4 4 Confirmation before operation 13 4 5 Operation procedure 13 5 Remote Cable Sold Separately 14 5 1 Electrical circuit diagram 14 5 2 Color and signal of each wir...

Page 4: ...t outdoors 0 40 80 Install the product in a place without dew condensation at room temperature ambient temperature 0 to 40 C humidity 80 or less High temperature and dew condensation may cause electri...

Page 5: ...Dispose of the product properly as industrial waste 2 Confirmation and Preparation at Arrival After unpacking make sure that all parts are provided Contact our company immediately if parts are damage...

Page 6: ...Secondary filter CHF 2030 50 Active Carbon Cassette ACC 3220 100 Exhaust filter HEP 3220 69 Remove the sticker before use 1 1 1 The sticker is pasted to the filter when shipping it To prevent the zeo...

Page 7: ...econdary filter Protecting the circuit and the blower Active carbon cassette Absorbing the odor HEPA Exhaust HEPA filter Exhaust treatment 1 Primary filter Zeolite Cassette Filter Shaking motor Active...

Page 8: ...o match usage conditions the installed flange can be changed without having to use any tools Replacement flanges are sold separately 75 Removal method Turn the flange counterclockwise to remove it Tur...

Page 9: ...ilure Never adopt star burst connection that may cause voltage drop If voltage drop occurs longer time is required for startup 3 ON OFF 30 3 ON OFF It causes the trouble if ON OFF is frequently operat...

Page 10: ...to perform vibration manually after a short operating time cumulative time of less than 1 hour press the OFF button then press and hold the Manual Vibration button for 20 seconds Vibration continues...

Page 11: ...utomatically activates the vibration function Operating Pressure Indication Pa Indicates the current operating pressure level kPa 0 2 Pa 0 2 Pa When the equipment is not operating the pressure indicat...

Page 12: ...ours Indicator lamp Shaking 0 1hour After automatic shaking Off Hand operation shaking 1hour After automatic shaking Light up Automatic shaking 24 Some estimate of the number of shaking times for 24 h...

Page 13: ...icator lamp of AT panel lights AT ON Press the ON switch to start operation Confirm that abnormal sounds such as metallic sounds are not generated Confirm that the suction hose is connected securely 4...

Page 14: ...Temperature correction is not provided Reference example 3 5 6 33 0 1 F Attach a noise limiter Approximately 33 0 1 F to the output terminals Nos 1 2 and 3 When adding inductors such as relays 33 0 1...

Page 15: ...operation Red white Remote control operation switching signal Short circuits the wires 4 and 8 to start remote operation The AT panel is disabled while the wires 4 and 8 are short circuited Yellow Cha...

Page 16: ...the capacity level is changed the set level is stored in memory The set capacity level remains in memory even after the main power switch is turned off AT ON Lo Hi To change the capacity level using...

Page 17: ...ration 1 20 Auto operation shake off total up 1 hours After stopping the operation Auto moving for 20sec 20 Hand operation shake off After stopping the operation put on the manual shake off button for...

Page 18: ...disconnect the power plug from the electrical outlet before starting inspection Do not confuse the back and front of the filter The filter grid frame should be located on the exhaust side Release 2 s...

Page 19: ...sitioned at the center move the vibration arm to the end position before removing the guard or other parts 2 Remove 2 screws on both sides of the guard for shaking and get the guard off The guard for...

Page 20: ...ve carbon ACC 3220 100 ACC ACC plate 1 ACC Move up the ACC plate and remove active carbon 1 4 Release 4 snap locks and remove exhaust filter cover Exhaust filter cover 4 snap locks 2 Remove exhaust fi...

Page 21: ...it 2 Applicable fuse CBA 1000AT2 HC DSA V1 100 115V 10A 2 CBA 1000AT2 HC DSA V1 T 200V CE 220 240V 5A 2 Inspection item Frequency Description Filter case Before operation Is the case closed completely...

Page 22: ...filters 3 30 After checking 1 to 3 above remove the cause of error and press the RESET switch Or turn OFF and ON the MAIN POWER switch to reset the error status Start the operation 30 minutes later Fu...

Page 23: ...Copyright CHIKO AIRTEC CO LTD 2013 23 9 Indication of DANGER Labels 10 Electrical Circuit Diagram...

Page 24: ...y side when hose is connected to the suction port Before the zeolite adheres to the Primary filter After 2 5 2 7 m 3 min Machinery Directive EN ISO12100 1 2003 EN ISO 12100 2 2003 EN ISO14121 1 2007 E...

Page 25: ...emo about purchase Model Manufacturer s serial number Date of purchase Start of operation Your name Address Phone Person in charge LTD 562 0012 2 27 24 2 27 24 Hakushima Minoh City Osaka apan 562 0012...

Reviews: