1

 

製品使用上のご注意

Cautions on Using Product

 

1.1 

全般 

General

 

 

設置、接続、運転、操作、点検、故障診断の作業は、取扱説明書の内容に従い、適切に行って下さい。

 

誤った作業を行うと、火災・感電・けがの原因になります。

 

Perform installation, connection, operation, manipulation, inspection and failure diagnosis work properly in 
accordance with the instruction manual. Incorrect work may cause fire, electrical shock and injury. 

1.2 

運搬・設置・保管・輸送の条件 

 

The condition of carry installation, transportation and safekeeping 

 

 

輸送・保管については安全な場所で、温度

-10

℃~

60

℃  湿度

80%

以下の範囲として下さい。

 

For  transport  and storage,  keep in a safe  place,  with  a  temperature  range  of  -10  to +60

  and  humidity 

below 80%. 

 

運搬や設置は、二人以上で行って下さい。落下などにより、けがをする恐れがあります。

 

During  carrying-in  and  installation,  enlist  the  help  of  others  when  carrying  heavy  objects  to  prevent  an 
accident. There is danger of injury due to falling. 

 

回転機器が内蔵されていますので、水平で振動の無い場所に設置して下さい。

 

Rotary equipment is built into the product. Install the product in a horizontal place without vibrations. 

 

爆発・引火性ガス・腐食の危険がある場所や、水のかかる場所、可燃物のそばでは使用しないで下さい。

 

Do not use the product in places with explosive or flammable gas, with corrosion risk, with water splashes 
or near combustible substances. 

 

本機は、屋内クリーンルーム内  又は、清浄度の高い工場に設置することを前提とした構造となっていますので、屋
外などには設置しないで下さい。

 

The product is designed to be installed in an indoor clean room or highly cleaned factory. Do not install it 
outdoors. 

 

常温(周囲温度

0

40

℃ 

/

  湿度

80

%以下)で、結露しない場所に設置して下さい。高温・結露は、電気部品の故

障、感電の原因になります。

 

Install  the  product  in  a  place without  dew  condensation  at  room  temperature  (ambient  temperature:  0  to 
40ºC,  humidity: 80%  or  less). High temperature  and  dew  condensation  may cause  electrical  parts  to  fail 
and may cause an electrical shock. 

 

排気口は十分なスペース(排気口より

100

㎜以上)を設けて下さい。排気口を塞ぐと正規の吸引力が発揮できませ

ん。また、ボックス内部で十分な冷却が行われないため、モータ焼けや電気部品の故障原因となります。

 

Provide sufficient space around the exhaust port (100 mm or more). 
Clogging the exhaust port disables the regular suction force, and may cause motor burning and electrical 
part failure due to insufficient cooling inside the product. 

 

フィルタの交換、メンテナンスのしやすい場所に設置して下さい。

 

(フィルタ交換のため、本体正面から

350

㎜以上のスペースが必要です。)

 

Install the product in a place where filter replacement and maintenance can be performed easily. 
(To replace filters, a space of 350 mm or more is required from the main body front face.) 

 

本機は歩行面から

0.2

2

mの範囲で設置してください。

 

Install the product in a place 0.2 to 2.0 m from the walking surface. 

 

本機の設置標高は

1,000

m以下です。

 

The installation height of the product is 1,000 m or less 

 

設置区分は汚染度Ⅱ

(

製造工場

)

です。

 

The installation classification is “Contamination level 

  (manufacturing plant).

 

1.3 

接続 

Connection

 

 

接続は、確実におこなって下さい。ケーブルを無理に曲げたり、引っ張ったりしないで下さい。

 

火災・感電の原因になります。

 

Connect the product securely. 
Do not bend or pull cables forcibly. Forcible bending or pulling may cause a fire and electrical shock. 

 

異なった電源で使用しないで下さい。また、アース線を接続してお使い下さい。

 

Use the correct power supply, and connect the ground wire. 

 

電源の過電圧カテゴリーは区分Ⅲです。(産業用装置など)

 

The category of over-voltage of the power supply is division 

  (industrial device). 

Summary of Contents for CBA-1000AT2-HC-DSA-V1

Page 1: ...arker is an energy saving type clean box that realizes air technology in a compact body Please read this instruction manual thoroughly and handle this machine correctly so that you can use it safely f...

Page 2: ...osene paint etc Explosive dust Aluminum magnesium titanium zinc epoxy etc Dust containing sparks Dust containing sparks generated by high speed cutters grinders welding machines etc Fire sources Cigar...

Page 3: ...AT panel 9 4 3 Remote connector 12 4 4 Confirmation before operation 13 4 5 Operation procedure 13 5 Remote Cable Sold Separately 14 5 1 Electrical circuit diagram 14 5 2 Color and signal of each wir...

Page 4: ...t outdoors 0 40 80 Install the product in a place without dew condensation at room temperature ambient temperature 0 to 40 C humidity 80 or less High temperature and dew condensation may cause electri...

Page 5: ...Dispose of the product properly as industrial waste 2 Confirmation and Preparation at Arrival After unpacking make sure that all parts are provided Contact our company immediately if parts are damage...

Page 6: ...Secondary filter CHF 2030 50 Active Carbon Cassette ACC 3220 100 Exhaust filter HEP 3220 69 Remove the sticker before use 1 1 1 The sticker is pasted to the filter when shipping it To prevent the zeo...

Page 7: ...econdary filter Protecting the circuit and the blower Active carbon cassette Absorbing the odor HEPA Exhaust HEPA filter Exhaust treatment 1 Primary filter Zeolite Cassette Filter Shaking motor Active...

Page 8: ...o match usage conditions the installed flange can be changed without having to use any tools Replacement flanges are sold separately 75 Removal method Turn the flange counterclockwise to remove it Tur...

Page 9: ...ilure Never adopt star burst connection that may cause voltage drop If voltage drop occurs longer time is required for startup 3 ON OFF 30 3 ON OFF It causes the trouble if ON OFF is frequently operat...

Page 10: ...to perform vibration manually after a short operating time cumulative time of less than 1 hour press the OFF button then press and hold the Manual Vibration button for 20 seconds Vibration continues...

Page 11: ...utomatically activates the vibration function Operating Pressure Indication Pa Indicates the current operating pressure level kPa 0 2 Pa 0 2 Pa When the equipment is not operating the pressure indicat...

Page 12: ...ours Indicator lamp Shaking 0 1hour After automatic shaking Off Hand operation shaking 1hour After automatic shaking Light up Automatic shaking 24 Some estimate of the number of shaking times for 24 h...

Page 13: ...icator lamp of AT panel lights AT ON Press the ON switch to start operation Confirm that abnormal sounds such as metallic sounds are not generated Confirm that the suction hose is connected securely 4...

Page 14: ...Temperature correction is not provided Reference example 3 5 6 33 0 1 F Attach a noise limiter Approximately 33 0 1 F to the output terminals Nos 1 2 and 3 When adding inductors such as relays 33 0 1...

Page 15: ...operation Red white Remote control operation switching signal Short circuits the wires 4 and 8 to start remote operation The AT panel is disabled while the wires 4 and 8 are short circuited Yellow Cha...

Page 16: ...the capacity level is changed the set level is stored in memory The set capacity level remains in memory even after the main power switch is turned off AT ON Lo Hi To change the capacity level using...

Page 17: ...ration 1 20 Auto operation shake off total up 1 hours After stopping the operation Auto moving for 20sec 20 Hand operation shake off After stopping the operation put on the manual shake off button for...

Page 18: ...disconnect the power plug from the electrical outlet before starting inspection Do not confuse the back and front of the filter The filter grid frame should be located on the exhaust side Release 2 s...

Page 19: ...sitioned at the center move the vibration arm to the end position before removing the guard or other parts 2 Remove 2 screws on both sides of the guard for shaking and get the guard off The guard for...

Page 20: ...ve carbon ACC 3220 100 ACC ACC plate 1 ACC Move up the ACC plate and remove active carbon 1 4 Release 4 snap locks and remove exhaust filter cover Exhaust filter cover 4 snap locks 2 Remove exhaust fi...

Page 21: ...it 2 Applicable fuse CBA 1000AT2 HC DSA V1 100 115V 10A 2 CBA 1000AT2 HC DSA V1 T 200V CE 220 240V 5A 2 Inspection item Frequency Description Filter case Before operation Is the case closed completely...

Page 22: ...filters 3 30 After checking 1 to 3 above remove the cause of error and press the RESET switch Or turn OFF and ON the MAIN POWER switch to reset the error status Start the operation 30 minutes later Fu...

Page 23: ...Copyright CHIKO AIRTEC CO LTD 2013 23 9 Indication of DANGER Labels 10 Electrical Circuit Diagram...

Page 24: ...y side when hose is connected to the suction port Before the zeolite adheres to the Primary filter After 2 5 2 7 m 3 min Machinery Directive EN ISO12100 1 2003 EN ISO 12100 2 2003 EN ISO14121 1 2007 E...

Page 25: ...emo about purchase Model Manufacturer s serial number Date of purchase Start of operation Your name Address Phone Person in charge LTD 562 0012 2 27 24 2 27 24 Hakushima Minoh City Osaka apan 562 0012...

Reviews: