background image

Chapter 4

 

Configuring Settings (MODE SELECT Mode) 

CMN015-005 

原本

  (Original instructions)                                                                                                                                                               

53

 

Chapter 4

 

  Configuring Settings (MODE 

SELECT Mode) 

4.1

 

Screen Transitions in MODE SELECT Mode 

To move to the MODE SELECT mode, press the MODE SELECT button during stoppage.

 

The Up/Down arrow buttons cycle through parameters.

 

 

 

4.2

 

Communication Format Setting Mode (When 

Equipped with Communication Function)

 

This mode sets the below listed items of serial communication format.

 

The settings are enabled after the power switch is turned off and back on.

 

Item 

Setting 

Default 

Communication station number 

1 to 25 

Baud rate 

9600bps

19200bps

 

38400bps

57600bps

 

115200bps 

9600bps 

Bit length and parity 

Bit length = 8 bits, with no parity

 

Bit length = 8 bits, odd parity

 

Bit length = 8 bits, even parity

 

Bit length = 9 bits, with no parity 

Bit length = 8 bits, with no parity 

Stop bit 

Stop bit = 1 bit

 

Stop bit = 2 bits 

Stop bit = 1 bit 

[Com Setting] 

[Volume Down ST] 

[Other Setting] 

[Error Data] 

Communication  Format  Setting  Mode 
(When  Equipped  with  Communication 
Function)

 

Page 53

 

Air  Volume-Down  Alert  Timing 
Setting Mode

  Page 54

 

Other Setting Mode

 

 

Page 55

 

Error History Mode

 

Page 56

 

Summary of Contents for CHP-5000AT3-DSA-UD

Page 1: ...of Cautions on Product Use of Instruction Manual hereinafter referred to as this manual and operate it after often reading this manual 本書はいつでも使用できるよう 大切に保管してください Please keep this manual carefully to be able to use it at any time 日 本 語 English パルス式集塵機 Pulse Dust Collector 型式 MODELS CHP 5000AT3 DSA UD 200V 取扱説明書 Instruction Manual ...

Page 2: ...working to achieve clean air with compact equipment while utilizing air technology effectively The CHP Series is an energy saving type clean box that realizes air technology in a compact body Please read this instruction manual thoroughly and handle this CHP Series machine correctly so that you can use it safely for a long time and enjoy its full performance 本文中の表記について About Notation 本書では 以下の表記に従っ...

Page 3: ......

Page 4: ...チコーエアーテック株式会社 CHIKO AIRTEC CO LTD 562 0012 大阪府箕面市白島 2 27 24 2 27 24 Hakushima Minoh Osaka 562 0012 Japan TEL 81 072 720 5151 FAX 81 072 720 5133 URL http chiko airtec jp ...

Page 5: ...1 設置 11 3 1 2 配線 配管 13 3 1 3 保護機能 14 3 2 運転 15 3 3 初期圧登録 15 第 4 章 各種設定 モードセレクトモード 16 4 1 モードセレクトモードでの画面遷移 16 4 2 通信フォーマット設定モード 通信機能装備時 16 4 3 風量不足お知らせタイミング設定モード 17 4 4 その他の設定モード 17 4 4 1 時刻合わせモード 18 4 4 2 積算稼働時間リセットモード 18 4 4 3 設定値リセットモード 19 4 5 エラー履歴モード 19 第 5 章 保守 点検 20 5 1 フィルタのメンテナンス 交換 20 5 1 1 1次フィルタのメンテナンス 交換 20 5 1 2 1次フィルタの交換 メンテナンス 1本づつ引き上げる場合 21 5 1 3 1次フィルタのメンテナンス 全部一緒に引き上げる場合 22 5 1 4...

Page 6: ...6 章 便利な使い方 オプション 29 6 1 リモートケーブル 29 6 1 1 電気回路図 29 6 1 2 ピンアサイン 31 6 1 3 リモート操作 32 6 2 通信機能 32 6 2 1 RS485 通信 32 6 2 2 イーサネット 32 第 7 章 付録 33 7 1 仕様 33 7 2 消耗品リスト 33 7 3 電気回路図 34 7 3 1 CHP 5000AT3 DSA UD 34 ...

Page 7: ... けがをする恐れがあります 注 意 輸送 保管は安全な場所で 温度 10 60 湿度 80 以下の範囲としてくだ さい 1 3 設置時のご注意 警 告 引火性 爆発性 腐食物質の霧 煙 ガスが滞留している場所や これらの付近 に設置しないでください 注 意 本機は 屋内クリーンルーム内または清浄度の高い工場に設置することを前提と した構造となっていますので 屋外などには設置しないでください 狭い吸引口で使用しないでください 吸引口が狭い 圧力が高い 状態で使用し続けるとモータが冷却出来ず高温にな る恐れがあります 回転機器が内蔵されていますので 水平で振動のない場所に設置してください 常温 周囲温度 0 40 湿度 80 以下 で 結露しない場所に設置してください 高温 結露は 電気部品の故障 感電の原因になります 吸引雰囲気温度 集塵対象の粉塵をとりまく周囲の温度 が高いとモータ能力の ...

Page 8: ...ださ い 火災 感電の原因になります 本機の仕様と異なる電源で使用しないでください 粉塵爆発のおそれのない乾いた粉塵の吸引に使用してください アース線は必ず接続して使用してください 注 意 運転中は移動させないでください 汚染度 1 の場所で使用してください 過電圧カテゴリーが区分Ⅱの電源で使用してください 停電時は 主電源スイッチを OFF にしてください 停電復旧時に けが 装置破損の原因になります フィルタは正しく取り付けて使用してください フィルタが取り付けられていなかったり 目詰まりや破損した状態で運転すると モータ内へ異物が混入し 故障の原因となります 1 5 その他のご注意 警 告 本機を分解 改造しないでください 感電 けがの原因になります 内部の点検や修理はお買い上げになった販売店にご連絡ください 設置 接続 運転 操作 点検 故障診断の作業は 取扱説明書の内容に従 い ...

Page 9: ...第 1 章 製品使用上のご注意 CMN015 005 原本の翻訳 Translation of the original instructions 5 日 本 語 1 6 危険シールの貼付位置 高電圧警告シール 高温警告シール ネームプレート 分解禁止シール 高電圧警告シール ネームプレート 高温警告シール 分解禁止シール 分解禁止シール ネームプレート 高電圧警告シール ...

Page 10: ... 吸着します 1 バルブブースター 1次フィルタ内のパルスエアーを整流させます 1 ゼオライト フィルタ表面に積層させ フィルタ表面へのヒュームの付着を 軽減させます ブロア冷却用排気フィルタ 排気をクリーンにします 1 フィルタレギュレータ 圧縮空気の圧力を調整します 設定値 0 45 0 55MPa 1 昇降用工具 本体をジャッキアップ ダウンさせるための工具 1 スタートアップガイド 集塵機の電源を入れて 使用する際に確認します 1 電源ケーブルは 付属しておりません 推奨ケーブル AWG12以上 耐圧 300V以上 ...

Page 11: ...クトを接続します AT3 パネル 操作パネル 本機を操作します 電池ボックス ボタン電池を収納しています リモートコネクタ リモートケーブル 別売 を接続します パルス室 パルス装置を収納しています 点検窓 内部の状況を確認するための点検用窓です ダストトレイ 集積した粉塵 ゼオライトを収納します ブロア冷却フィルタ室 ブロア冷却用フィルタを収納しています モータ室 モータを収納しています リリーフバルブ 内部の圧力を逃がします フィルタレギュレータ チリ落とし用圧縮空気の圧力を調整します 設定値 0 45 0 55MPa 吸込み口 吸気ダクトを接続します 1 次フィルタ室 1 次フィルタを収納しています 電源端子台 BOX 電源端子台を収納しています ...

Page 12: ...止するエラーが発生したときは 赤色ランプが点灯し 運転を継続するエラー 警告が発生したときは 赤色ランプが点滅します ボタン 運転中は ボタンを 1 回押すごとに能力が 1 レベル降下 上昇 します モードセレクトモード時は ボタンを 1 回押すごとにカーソルが 1 つ左 右 に移動します OFF ボタン 運転を停止します 停止中に 3 秒間長押しすると 登録した初期圧をクリアします 3 3 初期圧登録 15 ページ ON ボタン 運転を開始します ENTER ボタン 運転中は 3 秒間長押しすると初期圧登録に移行します 3 3 初期圧登録 15 ページ モードセレクトモード時は 設定項目の選択と数値データを決定します 第 4 章 各種設定 モードセレクトモード 16 ページ MODE SELECT ボタン 停止中は モードセレクトモードに移行します 第 4 章 各種設定 モードセレクトモ...

Page 13: ... 9 日 本 語 2 4 ディスプレイ表示 2 4 1 モードについて 2 4 2 停止中の表示 ボタンで表示を切り替えることができます 停止中 通常モード 運転中 ON ボタン OFF ボタン モードセレクトモード 16 ページ モードセレクトボタン 初期圧登録 15 ページ ENTER ボタン 3 秒押し 主電源スイッチ ON 初期圧登録クリア 15 ページ OFF ボタン 3 秒押し Ver ID Battery Date Time プログラムバージョン RS485 通信用局番 電池残量 日付 時間 時刻合わせモード 18 ページ ...

Page 14: ... 運転中の表示 ボタンで表示を切り替えることができます OP kPa SP kPa DP kPa EP kPa 外部圧 吸込圧 差圧 排気圧 Blower ブロア周辺温度 Motor rpm モータ回転数 現在運転中のモータの回転数を表示します Runtime h 積算稼働時間 リセット可 リセット後からの稼働時間を表示します 積算稼働時間リセットモード 18 ページ Total h 実働時間 リセット不可 トータルの稼働時間を表示します ...

Page 15: ... 項 目 内 容 周 囲 温 度 0 40 の範囲 周 囲 湿 度 80 RH 以下の範囲 結露のないこと 雰 囲 気 屋内 直射日光が当たらないこと 腐食性ガス 引火性ガス オイルミスト 粉塵のないこと ボタン電池絶縁シートの取り外し ボタン電池の絶縁シートを取り外す際には 通電状態で行ってください 1 本機を使用する前にボタン電池の絶縁シートを取り 外してください 2 電池カバー部から絶縁シートを引き抜きます 注 意 本体を通電せず絶縁シートを引き抜くと 著しく電池が消耗することがあります 注 意 運搬や設置は 二人以上で行って下さい 落下などにより けがをする恐れがあります 設置完了後 必ずストッパーで固定して下さい 電池カバー 絶縁シート 電池カバー 設置完了後 ストッパー4 カ所で固定する事 吊位置 ...

Page 16: ... 3 章 運転 12 フィルタレギュレータの取り付け フィルタレギュレータ設置箇所に取り付けます 注 意 レギュレータ内に合成油 有機化合物 化学薬品 切削油及びそのミスト等を付着させ ないでください メ モ ボタン電池は電源が OFF のときに消費されます 電源 ON 時 1μA 以下 電源 OFF 時 40 50μA 電池寿命 参考値 約 2 年 は 使用状況によって変わります 目安としてください ...

Page 17: ...2 配線 配管 配線 警 告 接続は 確実に行い ケーブルを無理に曲げたり 引っ張ったりしないでくださ い 火災 感電の原因になります 本機の仕様と異なる電源で使用しないでください アース線は必ず接続して使用してください 注 意 電圧低下の原因になりますので タコ足配線にしないでください 電圧が降下すると正常に動作しなくなり 故障の原因になります 本機の電源は 三相電源です 供給電圧の許容範囲は 10 です 1 電源端子台 BOX のネジを取り外し フタを外します 2 電源ケーブルを本機の電源端子台に接続しま す 3 電源ケーブルの電源側を電源に接続します ...

Page 18: ...55MPa 3 1 3 保護機能 注 意 フィルタが目詰まりしたまま運転を続けると下記の様な保護機能が働きます 保護機 能が働いた時点でブロア等にダメージが及ぶ可能性があります 直ちにフィルタ及び各部の点検を行ってください SP 吸込圧 上昇 フィルタ目詰まり等により 16 5kPa 付近に達すると リリーフバルブが作動します また 19kPa 付近で電流値は 26 5A に達し この状態が 10 秒以上続くと強制停止します 温度上昇 モータ温度が 80 を超えると ディスプレイに WARN1 が表示されます さらに 90 に達すると ERR04 が表示され 強制停止します 吸込み口 ...

Page 19: ... Y と表示され 初期圧力の更新登録を実施するか確認されます 4 更新登録を実施する場合は ENTER ボタンを押します 初期圧力の取得動作を開始します 実施しない場合は MODE SELECT ボタンを押すと通常動作に戻ります 5 能力レベル 1 から 7 まで順番に運転し 各能力レベルの差圧を自動取得します 初期圧力の取得動作中は ディスプレイに Initial DP Check と 能力レベルと差圧 が交互に表示されま す 6 登録が完了すると ディスプレイに Initial DP Entry と表示されて通常動作に戻ります 重 要 フィルタが必ず新品の状態で行ってください 初期圧力登録後 配管を変えた場合やフィルタを全て交換された場合 排気フィルタ除 く は 再度 初期圧力を更新登録してください 初期圧力が登録されていないと初期圧力未登録警告 WARN6 が表示されます 停止中に ...

Page 20: ... 19200bps 38400bps 57600bps 115200bps 9600bps ビット長とパリティ ビット長 8bit パリティなし ビット長 8bit パリティ奇数 ビット長 8bit パリティ偶数 ビット長 9bit パリティなし ビット長 8bit パリティなし ストップビット ストップビット 1 ビット ストップビット 2 ビット ストップビット 1 ビット 1 モードセレクトモードに移行します 2 ボタンを押して通信フォーマット設定モード Com Setting に移行します 3 ENTER ボタンを押します 通信局番の確認画面になり 現在の設定内容が表示されます 4 ボタンを押して設定する項目に移行します Com Setting Volume Down ST Other Setting Error Data 通信フォーマット設定モード 16 ページ 風量不足お知らせ...

Page 21: ...足警告 WARN4 を表示させるタイミングを任意で変更できます 1 モードセレクトモードに移行します 2 ボタンを押して風量不足お知らせタイミング設定モード Volume Down ST に移行します 3 ENTER ボタンを押します 現在の設定内容が表示されます 標準出荷設定値は 50 で 3 Down to 50 が表示されます 4 ボタンを押して 30 70 の間で選択します 設定値を下げると風量不足お知らせのタイミングが遅くなり 設定値を上げると早くなります 5 ENTER ボタンを押して設定内容を決定します 6 終了する場合は MODE SELECT ボタンを押して通常モードに戻ります 4 4 その他の設定モード 以下の項目を設定します 日付と時刻の設定 4 4 1 時刻合わせモード 18 ページ 積算稼働時間のリセット 4 4 2 積算稼働時間リセットモード 18 ページ 設定...

Page 22: ...に設定します 7 日付が設定されると 時刻の設定画面になります 8 ボタンを押して数値を変更します 9 ENTER ボタンを押して数値を決定します 時 分 秒の順に設定します 10 終了する場合は MODE SELECT ボタンを押して通常モードに戻ります 4 4 2 積算稼働時間リセットモード 積算稼働時間 Runtime をリセットします 1 モードセレクトモードに移行します 2 ボタンを押してその他の設定モード Other Setting に移行します 3 ENTER ボタンを押します Time Adjust が表示されます 4 ボタンを押して 表示を Runtime Reset にします 5 ENTER ボタンを押します Reset Runtime Y と表示され 積算稼働時間をリセットするか確認されます リセットする場合は ENTER ボタンを押してください 6 終了する場合は ...

Page 23: ...Time Adjust が表示されます 4 ボタンを押して 表示を Setting Reset にします 5 ENTER ボタンを押します 1 YES と表示され 設定値をリセットするか確認されます リセットする場合は ENTER ボタンを押してください 6 再確認のため 1 START と表示されます 7 ENTER ボタンを押すと設定値がリセットされ 通常モードに移行します 4 5 エラー履歴モード 4 件分のエラー履歴を確認することができます エラー履歴は電源を OFF するとクリアされます 1 モードセレクトモードに移行します 2 ボタンを押してエラー履歴モード Error Data に移行します 3 ENTER ボタンを押します 直近で発生したエラーNo と発生したときの積算稼働時間が表示されます 4 ボタンを押すと 新しい順に 4 件分のエラー履歴が表示されます 5 終了する場...

Page 24: ...タのメンテナンス 交換 重 要 1 次フィルタの交換は 十分なスペースがある場所で行ってください 1 2 本のチューブとパッチン錠 2 個を取り外しま す パッチン錠は反対側にもあります 2 レンチを取り付け ブロワー室を上昇させま す 4 注 意 保守 点検時は必ず電源を切り コンセントからプラグを抜いて 電路遮断を行っ てください 作業は 2 人以上で行い 必ず保護具を着用してください 摩耗や破損したフィルタをそのまま使用すると 内部の電気部品が損傷いたしま す 故障 事故の原因を未然に防ぐ為 保守 点検は必ず行ってください フィルタの交換は十分なスペースがある場所で行ってください また フィルタの取り付け時は 裏 表を間違えないでください 注 意 パッキン部に付いたゴミは ウエス等で綺麗に拭取り 清掃して下さい 吸引力低下 粉塵漏れ等といった トラブルの原因になります ...

Page 25: ... 本 語 3 ブロア室を 30mm 以上上昇させてください 5 1 次フィルタ室を手前に引き出します 5 1 2 1次フィルタの交換 メンテナンス 1本づつ引き上げる場合 1 12 本のナットを緩めて取り外し 取っ手を 持って押え板を外します 2 バルブブースターを外し 清掃又は交換し てください 注 意 洗浄後及び交換後のフィルタを取り付けの際 締め付けが均一でない場合や締め付 けが緩い場合は ゼオライトが漏れる可能性があります 又 年次劣化により 1 次フィルタに取り付けてあるパッキンが潰れている場合は 交 換となります 消耗品販売となります ...

Page 26: ...タ室を引き出します フィルタ取り付け板の取っ手を持ちあげる と 一式を取り外すことができます 2 パッキン上部 フィルタ取り付け板のパッキ ン当たり面を清掃してください 5 1 4 ダストトレイの清掃 重 要 ダストトレイに埃をためないでください 1 次フィルタの目詰まりの原因になります 使用後は ダストトレイの埃を廃棄してください 1 ダストトレイの 2 個のパッチン錠のみを外し ます パッチン錠は反対側にもあります 2 ジャッキを取り付け 30mm 以上上昇させま す 3 ダストトレイを引出し 清掃します ...

Page 27: ...tion of the original instructions 23 日 本 語 5 1 5 ブロア冷却フィルタの交換 注 意 フィルタの取り付け時は 裏 表を間違えないでください フィルタ格子の枠が排気側です 重 要 排気フィルタの交換は 十分なスペースがある場所で行ってください 1 アイボルト 4 カ所とパチン錠 4 カ所を外しま す 2 フタを取り外します 3 4 カ所ネジを緩めて裏面の押え枠を外しま す 4 フィルタを交換します ブロア冷却用フィルタ 押え枠 ...

Page 28: ...状態で行ってください 本体を通電せずに電池を交換すると著しく電池が消耗することがあります 1 本体を通電して下さい 2 電池カバーのネジ 2 個 を外し 電池カバ ーを取り外します 3 爪を右に押し ボタン電池を取り外します 4 新しいボタン電池に交換します 5 電池カバーを元通りに取付けます 6 本体の電源を遮断して下さい 5 3 日常点検 点検項目 頻 度 点検内容 フィルタケース 運転前 完全に閉じているか 吸込口 運転前 吸込口が閉ざされていないか 排気の状態 1 回 1 日 排気口が閉ざされていないか 操作パネルの状態 1 回 1 日 エラーや警告が表示されていないか ボタン電池 爪 ボタン電池カバー ...

Page 29: ...nstructions 25 日 本 語 5 3 1 パルスタイマーについて 本製品は電磁弁を 4 個搭載しております フィルタのゼオライト吸着補助と吸引力の低下を防ぐ為 設定周期にてパルスエアー 圧縮空気 を使用し払落 します パルスタイマー順序動作 AT3 パネル ON 25 秒間待機 ゼオライト巻き上げ ゼオライト巻き上げ 3 秒待機 25 秒待機 パルスエア作動 列 0 3 秒打ち 0 3 秒打ち 3 秒待機 25 秒待機 パルスエア作動 列 0 3 秒打ち 0 3 秒打ち 3 秒待機 左 右 前 フィルタ ...

Page 30: ... 先順位の高いものが表示されます 表示データ 交互に表示 エラーNo 2 MODE SELECT ボタンを押し エラー履歴モ ードに移行します 複数のエラー 警告が発生しているときは エ ラーNo の左側に件数が表示されます 3 複数のエラー 警告が発生しているときは ボタンを押して エラーNo を確認します 4 ディスプレイに表示されているエラーNo に対 応した処置を行います 5 4 2 エラー 警告一覧 27 ページ 5 MODE SELECT ボタンを押し エラークリアモ ードに移行します 6 エラー 警告を解除する場合は ENTER ボタンを押して通常モードに戻ります エラー 警告を解除しない場合は MODE SELECT ボタンを押して通常モードに戻ります エラー 警告を解除しなかった場合 運転を継続するエラー 警告の場合 全てのボタンが有効です 運転を停止するエラー 警告の場...

Page 31: ... RAM に書き込みで きない 点滅 運転 継続 当社にお問い合わせくださ い ERR08 通信異常 BCC 判定が不一致 点滅 運転 継続 当社にお問い合わせくださ い WARN1 内部温度上昇 ブロア周辺温度が異 常判定閾値に近い 点滅 運転 継続 5 5 故障と思ったら の の対策方法に従って処置を 行ってください 28 ページ WARN2 フィルタ交換時 期超過 風量低下状態で一定 時間以上運転継続 点滅 運転 継続 5 5 故障と思ったら の の対策方法に従って処置を 行ってください 28 ページ WARN3 圧力 吸込 不 足 吸込圧が低い 点滅 運転 継続 5 5 故障と思ったら の の対策方法に従って処置を 行ってください 28 ページ WARN4 風量不足 フィルタ目詰まりによ る風量低下 点滅 運転 継続 5 5 故障と思ったら の の対策方法に従って処置を 行ってくだ...

Page 32: ...切り 30 分経過してから 運転を 開始してください 1 次フィルタが取り付け られていない 1 次フィルタを正しく取り付ける 1次フィルタ室またはダ ストトレイのパッチン錠 が外れている 1次フィルタ室とダストトレイのパッチン錠を確 実に取り付ける 吸引力の低下 フィルタの目詰まり フィルタを交換する 5 1 フィルタのメンテナンス 交換 20 ページ 目詰まりを放置すると 粒子の吹きもれ や 集塵機内部の温度上昇 の原因となります 配管 吸込口の詰り 配管の詰りや吸込口が塞がれていないか確 認する モータ故障を起こして いる 修理を依頼してください モータ交換になります 粒子の吹きもれ フィルタの取り付け不 良 フィルタを取り付け直す 5 1 フィルタのメンテナンス 交換 20 ページ フィルタの破損 寿命 フィルタを交換する 5 1 フィルタのメンテナンス 交換 20 ページ フィル...

Page 33: ...転 ピン ON になると リモートモードに移行します 遠隔操作が可能になり AT3 パネルでの通常操作は出来なくなります ピン 圧力アナログ信号を出力します ピン インダクタ リレー等 を付加する場合は ノイズリミッタ 約 33Ω 0 1μF またはダイオード等 を取り付けてください 運転入力信号 遠隔操作切替信号 運転圧力信号 フィルタ目詰信号 運転信号 異常信号 能力レベル変更入力信号 耐圧 DC 50V 100mA 以下でご使用下さい GND DC 1 5V インダクタ リレー等 を付加する場合 は 出力端子 端子番号 に ノイ ズリミッター 約 33Ω 0 1μF を付けて 下さい LOAD LOAD DC 0 5V GND LOAD LOAD LOAD ...

Page 34: ...い方 オプション 30 接続例 ピン 入力 ピン アナログ出力 ピン オープンコレクタ出力 ピン 入力 参考回路 電圧を印加しないでください 参考回路 計測器等 出力電圧 1 5V 0 2V 状態 ポイント B C ON HIGH LOW OFF LOW HI Z ピンが LOW の時 負荷に電 流が流れます 定格を超えないよ うに保護回路を追 加してください 推奨 DC 電圧 電流 最大定格の 1 2 以 下 参考回路 ...

Page 35: ... 黄 白 GND 黒 白 運転圧力信号 出力信号 現在の運転圧力を出力します アナログ信号 1 5V インピーダンス 4 7kΩ 赤 フィルタ目詰出力信号 3 目詰まり信号を出力します オープンコレクタ出力 NPN 緑 運転出力信号 3 運転信号 ON ランプ を出力します オープンコレクタ出力 NPN 緑 白 異常信号 異常信号を出力します オープンコレクタ出力 NPN 目詰まり信号 WARN2 WARN4 WARN5 の場合 異常信号 全ての ERR の場合 1 接点入力 無電圧接点 2 アナログ入力 0 5V 5 0V 以上印加させないでください ピンの印加電圧閾値表 能力レベル 電圧 DCV 1 0 6 1 1 2 1 2 1 7 3 1 8 2 3 4 2 4 2 9 5 3 0 3 5 6 3 6 4 1 7 4 2 5 0 誤差が 4 あるため 電圧を設定する場合は 各レベル...

Page 36: ...い 6 1 2 ピンアサイン の説明に従い 必要な出力信号を取り出してください リモート操作移行中に本機側で初期圧登録 ON OFF の操作 能力レベルを変更することはできません 能力レベルを変更する時にレベルが記憶されるため 万が一主電源を切っても前回の能力レベルを記憶し ています 6 2 通信機能 オプションの通信ボードセット 型式 RS 485 もしくは RS EN を使用する事で 運転 ON OFF やフィルタ目 詰まり等の情報を取り出す事が可能です 6 2 1 RS485 通信 設定方法は 4 2 通信フォーマット設定モード 通信機能装備時 を参照してください 4 2 通信フォーマット設定モード 通信機能装備時 16 ページ 6 2 2 イーサネット 詳細については 別途購入されたイーサネットの取扱説明書を参照してください ...

Page 37: ...音値 1 質量 CHP 5000AT3 DSA UD 5000W 200V 三相 27 5A 50 60Hz 10 min 18 0kPa 68 74 dB 302 0kg 1 騒音値は吸込み口にホースを接続し 本機から 1m 離れて A スケール dB で測定しています 7 2 消耗品リスト 品名 型式 数量 交換時期 1 CHP 5000AT3 DSA UD 1 次フィルタ CS 200 500 75P R 4 本 メンテナンスは半年に 1 回 ブロア冷却用排気フィルタ AE 100 330 220 1 枚 6 ヵ月 ゼオライト ZEO 13000 13kg 1 3 ヵ月 1 交換周期はお客様の使用頻度 環境 吸い込み濃度 材質と成分 によって変わります ...

Page 38: ...第 7 章 付録 34 7 3 電気回路図 7 3 1 CHP 5000AT3 DSA UD ...

Page 39: ...場合に発生した故障または損傷の場合 本書に記載されている使用環境以外での使用による故障または損傷の場合 弊社および弊社指定の販売店以外で修理 改造 分解等をした場合 使用中に生じたキズ 汚れなどの外観上の変化の場合 消耗品 付属品の交換および弊社指定以外の部品を使用した場合 お買い上げ後の落下 および運送上の事故による故障または損傷の場合 火災 塩害 ガス害 地震 風水害 落雷 電圧異常およびその他の天変地異を原因とする故障または損 傷の場合 修理について 出張修理をご希望の場合 出張料金は 保証期間内外を問わず有料となります 修理の都合により 修理時に改良部品を使用する場合がございます 本機の故障による損害 データの抹消による損害 その他本機の使用により生じた損害について 弊社は一 切その責任を負いかねますので ご了承ください お買い上げメモ 形 式 製造番号 購入年月日 運転開始日 年...

Page 40: ...36 ...

Page 41: ...LECT Mode 53 4 2 Communication Format Setting Mode When Equipped with Communication Function 53 4 3 Air Volume Down Alert Timing Setting Mode 54 4 4 Other Setting Mode 55 4 4 1 Clock Calibration Mode 55 4 4 2 Accumulated Run Time Reset Mode 55 4 4 3 Setpoint Reset Mode 56 4 5 Error History Mode 56 Chapter 5 Maintenance and Checkup 57 5 1 Filter maintenance and replacement 57 5 1 1 Primary filter m...

Page 42: ...38 6 2 Communication Function 70 6 2 1 RS485 Communication 70 6 2 2 Ethernet 70 Chapter 7 Appendix 71 7 1 Specifications 71 7 2 Consumables List 71 7 3 Electrical Diagram 72 7 3 1 CHP 5000AT3 DSA UD 72 ...

Page 43: ...lammable explosive or corrosive mist smoke or gases CAUTION This device is designed for installation in a cleanroom or a clean factory Avoid installation in other areas such as outdoors Ensure a wide suction port If the device is used continuously with a narrow suction port i e at high pressure the motor may become hot as it cannot be cooled Install the device in a horizontal vibration free locati...

Page 44: ...vice to suck dry dust without potential dust explosion Be sure to connect the ground wire CAUTION Do not move the device while in operation Use the device in locations of pollution degree 1 Use a power supply of overvoltage category II Turn off the main power switch in case of power outage Injury or device damage can occur when power returns Ensure that filters are installed correctly If filters a...

Page 45: ...nal instructions 41 1 6 Safety Label Locations High voltage warning label High temperature warning label Nameplate Do not disassemble label High voltage warning label Nameplate High temperature warning label label label Nameplate High voltage warning label ...

Page 46: ...uces the adhesion of dust fumes on the filter surface Exhaust filter for cooling blower Clean the exhaust 1 Filter regulator Adjusts the pressure of compressed air for dust removal Configuration values 0 45 0 55MPa 1 Lifting and lowering tool wrench Tool for jacking up and down the main body wrench 1 Start up guide Please read this when you switch on the power and operate the device 1 Power cable ...

Page 47: ...er Stores the pulse device Inspection window A window to check the state inside the main body Dust tray Stores accumulated dust and zeolite Blower cooling filter chamber Stores the blower cooling filter Motor chamber Stores the motor Relief valve Relieve the internal pressure Filter regulator Adjusts the pressure of compressed air for dust removal Setting value 0 45 0 55MPa Suction port Connects a...

Page 48: ...flickers upon detection of an error or warning that continues device operation Left Right arrow buttons During operation each pressing of the Left or Right arrow button changes the suction power to the next lower or higher level During MODE SELECT mode each pressing of the Left or Right arrow button moves the cursor left or right to the next position OFF button Stops the operation During stoppage ...

Page 49: ...lay Indications 2 4 1 About Modes 2 4 2 Indications during Stoppage The Up Down arrow buttons cycle through indications Normal mode ON button OFF button Screen Transitions in MODE SELECT Mode page 53 MODE SELECT button Registering Initial Pressures Page 51 ENTER button Held down for 3 sec Main power switch ON Registering Initial Pressures Page 51 OFF button Held down for 3 sec During stoppage Duri...

Page 50: ...pressure Differential pressure Exhaust pressure Blower Temperature around blower Motor rpm Motor rotational frequency Indicates the rotational frequency of the currently running motor Runtime h Accumulated run time resettable Indicates run time accumulated since the last resetting Accumulated run time reset mode Page 55 Total h Actual run time not resettable Indicates the total run time ...

Page 51: ... conditions Item Description Ambient temperature 0 to 40 C Ambient humidity 80 RH or lower without dew condensation Ambient conditions Indoors not exposed to direct sunlight free of corrosive flammable gases oil mist and dust CAUTION Two or more people are required to move or install the unit There is a risk of injury if the unit falls over Make sure you secure the unit with a stopper after instal...

Page 52: ...of the battery if the insulation sheet is removed while the device is turned off Installing the filter regulator Install the filter regulator into the installation position CAUTION Do not allow synthetic oils organic compounds chemicals cutting oils or spray from these to adhere inside the regulator Note The button battery drains when the power switch is OFF 1 μA when power is ON 40 to 50 μA when ...

Page 53: ...vice Be sure to connect the ground wire CAUTION Avoid multiple connections as they can cause voltage reduction At reduced voltage the device may fail to operate normally resulting in failure The device is powered by three phase supply The tolerance of the supply voltage is 10 1 Remove the power terminal block BOX lid by extracting its screws 2 Connect the power cable to the power terminal block of...

Page 54: ...d or fail to operate when safeguards are activated Immediately inspect the filter and the parts thereof SP Suction pressure increase When the pressure reaches around 16 5 kPa due to filter clogging etc the relief valve will be activated In addition the current reaches 26 5 A at around 19 kPa If this condition continues for more than 10 seconds it cuts out automatically Temperature increase When th...

Page 55: ...vice starts to acquire initial pressure If you do not want to update press the MODE SELECT button to return to normal operation 5 The device runs through a sequence of suction power levels 1 to 7 to automatically acquire the differential pressure for each level While the device is acquiring initial pressure the display alternates between the Initial DP Check message and the suction power level and...

Page 56: ...Chapter 3 Operation 52 English 3 When the clearing completes the display shows the Initial DP Clr message and the device returns to the stop state ...

Page 57: ...tings are enabled after the power switch is turned off and back on Item Setting Default Communication station number 1 to 25 1 Baud rate 9600bps 19200bps 38400bps 57600bps 115200bps 9600bps Bit length and parity Bit length 8 bits with no parity Bit length 8 bits odd parity Bit length 8 bits even parity Bit length 9 bits with no parity Bit length 8 bits with no parity Stop bit Stop bit 1 bit Stop b...

Page 58: ...g 8 To exit this mode press the MODE SELECT button to return to normal mode 4 3 Air Volume Down Alert Timing Setting Mode This mode allows for changing the timing for displaying an air volume down warning WARN4 as desired 1 Move to the MODE SELECT mode 2 Press the Up Down arrow buttons to move to the air volume down alert timing setting mode Volume Down ST 3 Press the ENTER button The current sett...

Page 59: ...lue Set the value in this order year month and day 7 After the date is set the time setting screen appears 8 Press the Up Down arrow buttons to change the value 9 Press the ENTER button to determine the value Set the value in this order hours minutes and seconds 10 To exit this mode press the MODE SELECT button to return to normal mode 4 4 2 Accumulated Run Time Reset Mode This mode resets the acc...

Page 60: ...et setpoints To reset press the ENTER button 6 The display shows 1 START for reconfirmation 7 Press the ENTER button to reset the setpoints and move the device to normal mode 4 5 Error History Mode The error history allows for checking four occurrences of errors The error history is cleared by turning off the power switch 1 Move to the MODE SELECT mode 2 Press the Up Down arrow buttons to move to ...

Page 61: ...ilter the correct way round IMPORTANT Lay a protective sheet outside the clean room before replacing Depending on the type of dust collected dust may scatter when replacing Wear protective goggles and mask during any work 5 1 Filter maintenance and replacement If clogging occurs a WARN2 warning appears Replace the primary filter CAUTION Wipe off any foreign particles adhering to the packing parts ...

Page 62: ...g up each piece one by one 1 Unscrew and remove the 12 nuts and remove the presser plate holding the handle in place 2 Remove the valve booster and clean Or replace it CAUTION When installing the filter after cleaning or replacement zeolite may leak if it is tightened unevenly or loosely Also if the packing attached to the primary filter has deteriorated due to age replace it Consumables sold sepa...

Page 63: ... the primary filter sets 2 Clean the upper section of the seal and the area of the filter mounting plate in contact with the seal 5 1 4 Cleaning the dust tray IMPORTANT Do not let dust accumulate in the dust tray It may cause clogging of the primary filter Dispose of dust after use 1 Release two latches only of the dust tray There are also latches on the other side 2 Attach the wrench and raise th...

Page 64: ...frame of the filter grating should face the exhaust side IMPORTANT The exhaust filter should be replaced in an area with a large free space 1 Remove the four eyebolts and release the four latches 2 Remove the cover 3 Loosen the four screws and remove the presser plate 4 Replace the blower cooling filter Blower cooling filter Presser plate ...

Page 65: ...the device 2 Remove the battery cover by extracting its two screws 3 Push the claw rightward and remove the button battery 4 Replace with a new button battery 5 Install the battery cover back in place 6 Cut off the electricity of the device 5 3 Daily Checkup Check item Frequency Check that Filter case Before operation Filter case is completely closed Suction port Before operation Suction port is n...

Page 66: ...filters with the pulse air compressed air according to the cycle setting Pulse timer operating sequence AT3 panel ON 25 second waiting time Scatter zeolite Scatter zeolite 3 second waiting time 25 second waiting time No 1 pulse air start 0 3 second shot 0 3 second shot 3 second waiting time 25 second waiting time No 2 pulse air start 0 3 second shot 0 3 second shot 3 second waiting time Left Right...

Page 67: ...yed alternately Error No 2 Press the MODE SELECT button to move to the error history mode If there are two or more error warning occurrences the number of occurrences precedes the error number 3 If there are two or more error warning occurrences press the Up Down arrow buttons to check the error numbers 4 Take an action appropriate for the error number shown on the display 5 4 2 Error Warning Tabl...

Page 68: ...e blower is close to the error threshold Flashing Remains operational Follow the remedies for in 5 5 Troubleshooting Page 65 WARN2 Filter replacement time limit expired Operation continued at low air volume for more than preset period Flashing Remains operational Follow the remedies for in 5 5 Troubleshooting Page 65 WARN3 Inadequate pressure suction Suction pressure is low Flashing Remains operat...

Page 69: ...the temperature thermostat of the motor may be active Turn off the main power and after 30 minutes resume the operation Primary filter not in place Install the primary filter correctly Latches are unfastened Fastens the latches Lower suction force Clogged filter Replace filters Page57 If filters are left clogged the device may result in untrapped particles or temperature rise in dust collector Clo...

Page 70: ...In case of adding an inductor e g relay install a noise limiter approx 33 Ω 0 1 μF diode or the like Operation input signal Remote operation change signal Operating pressure signal Filter clogging signal Operation signal Abnormality signal GND DC 1 5V When adding an inductor e g relay attach a noise limiter approx 33 Ω 0 1 μF to the output terminal terminal numbers and LOAD LOAD DC 0 5V GND LOAD L...

Page 71: ...V Max rating 50 V Load 100 mA Recommended DC voltage current 1 2 of maximum rating Pin Pin Connection examples Pins and input Pin analog output Pins and open collector output State Point B C ON HIGH LOW OFF LOW HI Z Output voltage 1 to 5 V 0 2 V Device side Reference circuit Do not apply voltage voltage Device side Customer side Pin or Customer side Pin Pin Pin Measuring instrument etc Reference c...

Page 72: ...Chapter 6 Useful Utilization Optional 68 English Pin input Reference circuit Device side Customer side Pin Pin Applied voltage 0 to 5 Vdc ...

Page 73: ...logging output signal 4 Outputs a clogging signal Open collector output NPN Green Operation output signal 3 Outputs an operation signal ON lamp Open collector output NPN Green white Abnormality signal detection 3 Anomalous signal Detection Open collector output NPN Filter clogging signal When WARN2 WARN4 or WARN5 occurred Abnormality signal When any ERR occurred 1 Contact input non voltage contact...

Page 74: ...the device side during transition to remote operation The current suction power level is stored in memory This means that the previously effective level is stored even if main power is turned off 6 2 Communication Function By using optional communication board set model RS 485 or RS EN you can retrieve information such as operation ON OFF and filter clogging 6 2 1 RS485 Communication See Communica...

Page 75: ...Noise value is measured with a hose connected to the suction port at a distance of 1 m from the device on the A scale 7 2 Consumables List Part name Model Quantity Replacement intervals 1 CHP 5000AT3 DSA UD Primary filter CS 200 500 75P R 4 Maintenance once in six months Exhaust filter for cooling blower AE 100 330 220 1 6 months Zeolite ZEO 13000 13kg 1 to 3 months 1 The replacement intervals var...

Page 76: ...Chapter 7 Appendix 72 English 7 3 Electrical Diagram 7 3 1 CHP 5000AT3 DSA UD ...

Page 77: ...IRTEC designated sales agent Blemish contamination or other appearance change that may occur during use Replacement of any consumable or accessory or use of any part not designated by CHIKO AIRTEC Failure of damage due to falling after purchase or accident during transport Failure or damage due to natural disasters such as fire salt damage gaseous damage earthquake wind and flood damage lightning ...

Reviews: