Chapter 4
Configuring Settings (MODE SELECT Mode)
CMN015-005
原本
(Original instructions)
53
Chapter 4
Configuring Settings (MODE
SELECT Mode)
4.1
Screen Transitions in MODE SELECT Mode
To move to the MODE SELECT mode, press the MODE SELECT button during stoppage.
The Up/Down arrow buttons cycle through parameters.
4.2
Communication Format Setting Mode (When
Equipped with Communication Function)
This mode sets the below listed items of serial communication format.
The settings are enabled after the power switch is turned off and back on.
Item
Setting
Default
Communication station number
1 to 25
1
Baud rate
9600bps
、
19200bps
、
38400bps
、
57600bps
、
115200bps
9600bps
Bit length and parity
Bit length = 8 bits, with no parity
Bit length = 8 bits, odd parity
Bit length = 8 bits, even parity
Bit length = 9 bits, with no parity
Bit length = 8 bits, with no parity
Stop bit
Stop bit = 1 bit
Stop bit = 2 bits
Stop bit = 1 bit
[Com Setting]
[Volume Down ST]
[Other Setting]
[Error Data]
Communication Format Setting Mode
(When Equipped with Communication
Function)
Page 53
)
Air Volume-Down Alert Timing
Setting Mode
Page 54
)
(
Page 55
)
Page 56
)
Summary of Contents for CHP-5000AT3-DSA-UD
Page 3: ......
Page 38: ...第 7 章 付録 34 7 3 電気回路図 7 3 1 CHP 5000AT3 DSA UD ...
Page 40: ...36 ...
Page 76: ...Chapter 7 Appendix 72 English 7 3 Electrical Diagram 7 3 1 CHP 5000AT3 DSA UD ...