5.3 

各線の色と信号について

Color and signal of each wire 

 

 

 

入力 

INPUT

   

・①,④

 

:接点入力(無電圧接点)  Contact input (no-voltage contact) 

・  ⑦

 

:アナログ入力(

0

5V

)   

Analog

 

input voltage (0 to 5V) 

                 

+5.0V

以上印加させないでください。

 

Do not apply voltage exceeding 

5.0V.

 

 

出力 

OUTPUT 

・③,⑤  :オープンコレクタ出力 

Open collector output 

絶対最大定格 

Absolute Maximum Ratings

  :電圧

(Voltage)

  :

50

V  ,電流(

Current

):

100 mA 

                          *推奨値:  定格の

1/2

以下

   

Recommended value: less than 1/2 of the rated 

 

②  :アナログ出力(

0

5V

)   

Analog output voltage (0 to 5V) 

 

 
 
 
 

 

⑦(黄)は、他の線と短絡させないで下さい。

AT

パネルが損傷し、故障の

原因となります。

 

Do not short-circuit the wire [7] (yellow) with other wires. 
Such short-circuit may damage the AT panel, and cause 
failure.

 

線色

 

 

Wire color

 

PIN

 

NO. 

信号名称 

  Signal

 

name 

 

役割 

  Role 

黒 

   

Black

 

 

運転入力信号 

 

Operation input signal 

遠隔信号

(

入力

Rem

o

te

 s

ig

n

a

ls

 

①と④と⑧を短絡して運転を開始させます

 

 

Short-circuits the wires [1], [4] and [8] to start operation.

 

/

 

  Red/white

 

 

遠隔操作切替信号

 

Remote-control operation 
switching signal 

④と⑧を短絡してリモート操作に移行させます

 

短絡するとタッチパネルの操作はできなくなります

 

Short-circuits the wires [4] and [8] to start remote operation. 

The AT panel is disabled while the wires [4] and [8] are 

short-circuited.

 

/

 

 

Yellow /white

 

 

Gnd

 

 

/

 

Black/White

 

 

運転圧力信号

 

Operation pressure signal 

出力信号

 

 

O

u

tp

u

s

ig

n

a

ls

 

現在の運転圧力を取り出します

 

Transfers the current operation output. 

アナログ信号

  Analog signal

1

5V

 

インピーダンス

  Impedance

  (≧

4.7

kΩ)

 

 

Red

 

 

フィルタ目詰出力信号

 

Filter clogging output signal 
 

目詰まり信号を取り出します

 

Transfers the clogging signal. 

オープンコレクタ出力

 

Open collector output 

 

Green

 

 

運転出力信号

 

Operation output signal 

運転信号(ONランプ)を取り出します

 

Transfers the operation signal (ON indicator lamp). 

オープンコレクタ出力

 

Open collector output 

/

 

Green/White

 

 

圧力不足出力信号

 

Pressure down output signal 
 

圧力不足信号を取り出します

 

Transfers the 

” pressure down “ signal   

オープンコレクタ出力

 

Open collector output 

 

Yellow

 

 

サービス電源

 

Service power supply 
 

サービス電源を取り出すことができます

 

他のケーブルとは短絡しないで下さい。

 

Transfers the service power supply. 
Do not short circuit this wire with other wires. 

DC 

12

 

負荷インピーダンス 

Impedance

(≧

1

kΩ)

 

Summary of Contents for CHV-030AD-HC-V1

Page 1: ...a compact body Please read this instruction manual thoroughly and handle this CHV Series machine correctly so that you can use it safely for a long time and enjoy its full performance Symbols used in...

Page 2: ...osene paint etc Explosive dust Aluminum magnesium titanium zinc epoxy etc Dust containing sparks Dust containing sparks generated by high speed cutters grinders welding machines etc Fire sources Cigar...

Page 3: ...l 7 4 3 Remote connector 8 4 4 Confirmation before operation 8 4 5 Operation procedure 9 5 Remote Cable Sold Separately 10 5 1 Electrical circuit diagram 10 5 2 Remote Cable 11 5 3 Color and signal of...

Page 4: ...ctory Do not install it outdoors 0 40 80 Install the product in a place without dew condensation at room temperature ambient temperature 0 to 40 C humidity 80 or less High temperature and dew condensa...

Page 5: ...ectrical shock and injury Contact your dealer for internal inspection and repair 1 6 Disposal Dispose of the product properly as industrial wast 2 Confirmation and Preparation at Arrival After unpacki...

Page 6: ...dust and fumes Exhaust port AT AT Panel operation panel Suction port MAIN POWER switch DC DC power connector Remote connector Primary filter Secondary filter MT 173 8 Remote cable option The remote c...

Page 7: ...forms blocking and ability decreased C F indication turns on a panel Operating the product with a different power supply may cause a failure 3 ON OFF 30 3 ON OFF It causes the trouble if ON OFF is fre...

Page 8: ...D ON Red LED light Starts the dust collector Possibility to record suction level OFF OFF Stops operation of the dust collector 4 3 Remote connector 3M It is possible to transfer the operation signal i...

Page 9: ...llector AT ON Press the ON switch to start the operation 5 Choose operation ability in five levels Push Lo switch or Hi switch in AT panel Note The air volume is adjustable in the nonstop method from...

Page 10: ...tput signal Connection Example 5 Remote Cable Sold Separately 5 1 Electrical circuit diagram Remote operation switch ON Shifting to remote mode Remote control is possible in the ON and the panel is im...

Page 11: ...Copyright CHIKO AIRTEC CO LTD 2009 11 5 2 Remote Cable The wire 7 yellow is put inside a shrinkable tube so that it cannot be short circuited with other wires...

Page 12: ...he wires 1 4 and 8 to start operation Red white Remote control operation switching signal Short circuits the wires 4 and 8 to start remote operation The AT panel is disabled while the wires 4 and 8 ar...

Page 13: ...it the wires 4 and 8 each other when transferring signals by turning ON and OFF the dust collector from the main body Transfer required output signals in accordance with the explanation in 5 3 Color a...

Page 14: ...he filter grid frame should be located on the exhaust side Make sure to turn OFF the main power and disconnect the power plug from the electrical outlet to cut off the electricity before starting insp...

Page 15: ...s into the clearance on the left and right sides between the filter case and the filter to remove the filter easily Remove the primary filter from the filter case The paper packing of the primary filt...

Page 16: ...day Is the exhaust port unclogged Vibrations of main body Once day Are no abnormal vibrations or sounds generated Is the installation level correct Filter installation status Once month Are the filter...

Page 17: ...f several plugs in one outlet is not adopted 2 Confirm that the motor is not overheated by clogged filters The suction force is deteriorated Filters are clogged Replace filters Clogged filters lead to...

Page 18: ...filter 2 Secondary filter HEPA Exhaust HEPAfilter Life 1 2 1 to 2 months 1 3 1 to 3 months 6 1 6 months to 1 year CHV 030AD HC V1 FB 15 CHF 1714 30 HEP 1714 30 Note The life above varies depending on...

Page 19: ...emo about purchase Model Manufacturer s serial number Date of purchase Start of operation Your name Address Phone Person in charge LTD 562 0012 2 27 24 2 27 24 Hakushima Minoh City Osaka apan 562 0012...

Reviews: