background image

チコーエアーテック株式会社 

Copyright CHIKO AIRTEC CO., LTD. 2009 

 

 

 

  15

 

 

 

 

6.3 

1次・2次フィルタの交換   

Replacement of primary and secondary filters

 

 
 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

 
 
 
 
 

 
 
 
 
 
 

 

 

6.4 

排気

HEPA

フィルタの交換   

Replacement of exhaust HEPAfilte

 

 
 
 
 
 
 
 
 
 
 
 
 

 
 
 
 
 
 
 
 

 

①フィルタケースのパッチン錠を

外します 

Release the snap locks of the 

filter case.

 

②フィルタケースを開け、2次フィルタを取り外す 
《フィルタケースとフィルタのスキマ(左右)にマイナスドライバ
ーを差し込むと容易にフィルタが取り外せます。》 

Open the filter case, and remove the secondary filter. 

(Insert screwdrivers into the clearance (on the left and 

right sides) between the filter case and the filter to 

remove the filter easily.)

 

 

 
 

③フィルタケースより1次フィルタを取り外します 
《1次フィルタはフィルタケースの円筒パイプにフィルタ紙パッ
キン部を差し込んでいます。手前に引き抜けば外せます。》 

Remove the primary filter from the filter case. 

(The paper packing of the primary filter is inserted into 

the cylindrical pipe of the filter case.    Pull the paper 

packing toward you to remove the primary filter.)

 

①パッチン錠左右の2ヶ所を外します 

Release two snap locks on the left and 
right sides

 

②排気口扉を外し、排気 HEPA フィルタを取り出します 

Remove the exhaust port door, and take out the 
exhaust    HEPAfilter. 

 

Summary of Contents for CHV-030AD-HC-V1

Page 1: ...a compact body Please read this instruction manual thoroughly and handle this CHV Series machine correctly so that you can use it safely for a long time and enjoy its full performance Symbols used in...

Page 2: ...osene paint etc Explosive dust Aluminum magnesium titanium zinc epoxy etc Dust containing sparks Dust containing sparks generated by high speed cutters grinders welding machines etc Fire sources Cigar...

Page 3: ...l 7 4 3 Remote connector 8 4 4 Confirmation before operation 8 4 5 Operation procedure 9 5 Remote Cable Sold Separately 10 5 1 Electrical circuit diagram 10 5 2 Remote Cable 11 5 3 Color and signal of...

Page 4: ...ctory Do not install it outdoors 0 40 80 Install the product in a place without dew condensation at room temperature ambient temperature 0 to 40 C humidity 80 or less High temperature and dew condensa...

Page 5: ...ectrical shock and injury Contact your dealer for internal inspection and repair 1 6 Disposal Dispose of the product properly as industrial wast 2 Confirmation and Preparation at Arrival After unpacki...

Page 6: ...dust and fumes Exhaust port AT AT Panel operation panel Suction port MAIN POWER switch DC DC power connector Remote connector Primary filter Secondary filter MT 173 8 Remote cable option The remote c...

Page 7: ...forms blocking and ability decreased C F indication turns on a panel Operating the product with a different power supply may cause a failure 3 ON OFF 30 3 ON OFF It causes the trouble if ON OFF is fre...

Page 8: ...D ON Red LED light Starts the dust collector Possibility to record suction level OFF OFF Stops operation of the dust collector 4 3 Remote connector 3M It is possible to transfer the operation signal i...

Page 9: ...llector AT ON Press the ON switch to start the operation 5 Choose operation ability in five levels Push Lo switch or Hi switch in AT panel Note The air volume is adjustable in the nonstop method from...

Page 10: ...tput signal Connection Example 5 Remote Cable Sold Separately 5 1 Electrical circuit diagram Remote operation switch ON Shifting to remote mode Remote control is possible in the ON and the panel is im...

Page 11: ...Copyright CHIKO AIRTEC CO LTD 2009 11 5 2 Remote Cable The wire 7 yellow is put inside a shrinkable tube so that it cannot be short circuited with other wires...

Page 12: ...he wires 1 4 and 8 to start operation Red white Remote control operation switching signal Short circuits the wires 4 and 8 to start remote operation The AT panel is disabled while the wires 4 and 8 ar...

Page 13: ...it the wires 4 and 8 each other when transferring signals by turning ON and OFF the dust collector from the main body Transfer required output signals in accordance with the explanation in 5 3 Color a...

Page 14: ...he filter grid frame should be located on the exhaust side Make sure to turn OFF the main power and disconnect the power plug from the electrical outlet to cut off the electricity before starting insp...

Page 15: ...s into the clearance on the left and right sides between the filter case and the filter to remove the filter easily Remove the primary filter from the filter case The paper packing of the primary filt...

Page 16: ...day Is the exhaust port unclogged Vibrations of main body Once day Are no abnormal vibrations or sounds generated Is the installation level correct Filter installation status Once month Are the filter...

Page 17: ...f several plugs in one outlet is not adopted 2 Confirm that the motor is not overheated by clogged filters The suction force is deteriorated Filters are clogged Replace filters Clogged filters lead to...

Page 18: ...filter 2 Secondary filter HEPA Exhaust HEPAfilter Life 1 2 1 to 2 months 1 3 1 to 3 months 6 1 6 months to 1 year CHV 030AD HC V1 FB 15 CHF 1714 30 HEP 1714 30 Note The life above varies depending on...

Page 19: ...emo about purchase Model Manufacturer s serial number Date of purchase Start of operation Your name Address Phone Person in charge LTD 562 0012 2 27 24 2 27 24 Hakushima Minoh City Osaka apan 562 0012...