Chapter 4 Configuring Settings(MODE SELECT Mode)
44
Chapter 4
Configuring Settings(MODE
SELECT Mode)
4.1
Screen Transitions in MODE SELECT Mode
To move to the MODE SELECT mode, press the
MODE SELECT
button during stoppage.
The
Up/Down arrow buttons
cycle through parameters.
4.2
Communication Format Setting Mode(When
Equipped with Communication Function)
This mode sets the below listed items of serial communication format.
The settings are enabled after the main power switch is turned off and back on.
Item
Setting
Default
Communication station number
1 to 25
1
Baud rate
9600 bps, 19200 bps,
38400 bps, 57600 bps,
115200 bps
9600 bps
Bit length and parity
Bit length = 8 bits, with no parity
Bit length = 8 bits, odd parity
Bit length = 8 bits, even parity
Bit length = 9 bits, with no parity
Bit length = 8 bits, with no parity
Stop bit
Stop bit = 1 bit
Stop bit = 2 bits
Stop bit = 1 bit
1.
Move to the
MODE SELECT
mode.
2.
Press the
Up/Down arrow buttons
to move to the communication format setting mode
(“
Com Setting
”).
3.
Press the
ENTER
button.
The communication station number check screen appears, showing the current settings.
4.
Press the
Up/ Down
arrow buttons to move to the item you want to set.
5.
Press the
ENTER
button.
The setting screen appears.
6.
Press the
Up/Down
arrow buttons to select the desired setting.
[Com Setting]
[Volume Down ST]
[Other Setting]
[Error Data]
Communication format setting mode
(
Air volume-down alert timing setting mode
(
Other setting mode
(
Error history mode
(