Chapter 3
Operation
44
E
nglis
h
3.1.2
Wiring and Piping
■
Wiring
WARNING
•
Perform wiring firmly, without bending or pulling cables with excessive force.
Fire or electric shock may result.
•
Ensure that the power supply conforms to the specifications of the device.
•
Be sure to connect the ground wire.
CAUTION
•
Avoid multiple connections as they can cause voltage reduction.
At reduced voltage, the device may fail to operate normally, resulting in
failure.
The device is powered by a single-phase supply.
The tolerance of the supply voltage is
10%.
1.
Connect the device attachment plug of the power cord to the power connector on the device.
2.
Connect the power supply end of the power cord to the power outlet.
■
Piping
1.
Turn the removable flange clockwise until it is
secured on the suction port.
2.
Connect the suction tube (to be prepared
separately) to the removable flange.
IMPORTANT
•
Ensure appropriate piping during operation.
The piping should be as short as practicable, with the piping port diameter not too
small.
3.2
Operation
1.
Turn on the main power switch.
The display indicates the program version
and the ID for RS485 communication.
2.
Press the ON button on the AT3 panel.
The device starts operation.
3.
Check that abnormal noise is not generated
and the suction is appropriate.
4.
Set a desired suction power by pressing the
Left/Right arrow buttons.
The suction power is indicated by the
suction power level lamps (1 to 7).
IMPORTANT
【
ON/ OFF
】
Leave an interval of three minutes or more.
Repeated on/off switching at intervals of less than three minutes, in particular less
than 30 seconds, may cause failure.
Ver*.** ID.**
Removable
flange
Left/Right
arrow buttons
Suction power
level lamps
Summary of Contents for CKU-080AT3-HC
Page 6: ...1 4 1 4 2 OFF 1 5...
Page 7: ...1 CMN003 006 Translation of the original instructions 5 1 6...
Page 12: ...2 10 2 4 3 OP kPa SP kPa DP kPa EP kPa Blower Motor rpm Runtime h 16 Total h...
Page 14: ...3 12 3 1 2 10 1 2 1 2 3 2 1 ON RS485 ID 2 AT3 ON 3 4 1 7 3 ON OFF 3 30 ON OFF Ver ID...
Page 20: ...5 18 5 1 2 CKU 450AT3 HC 1 1 2 1 3 1 4 2 5 2...
Page 26: ...5 24 5 7 EL ON ON 5 2 20 1 2 3 4 1 4 ON OFF 30 1 2 1 2 5 1 17 5 1 17 5 1 17 5 1 17...
Page 27: ...6 CMN003 006 Translation of the original instructions 25 6 6 1 6 1 1...
Page 28: ...6 26 1 5V 0 2V DC 1 2...
Page 32: ...7 30 7 3 7 3 1 CKU 080AT3 HC 7 3 2 CKU 240AT3 HC CKU 450AT3 HC...
Page 33: ...CMN003 006 Translation of the original instructions 31 12 7 2 7 2 29...
Page 34: ...32...
Page 66: ...MEMO...