  18

 

 

 

 

6.7 

ヒューズの交換 

Replacement of fuses 

 

 

 

 
 
 
 
 
 
 
 

 

 
 
 
 
 
 

 

※出荷時のヒューズ  :   

218

シリーズ

 

タイムラグ型

  (Litte

lfuse

   

      Fuse at the time of the shipment

  : 

218 series Time lag type (Product made in Littellfuse) 

 

6.8 

日常点検

 

Daily inspection 

点検項目

 

Inspection item

 

頻度

 

Frequency

 

点検内容

 

Description

 

フィルタケース

 

Filter case 

運転前

 

Before operation 

完全に閉じているか

 

Is the case closed completely? 

排気の状態

 

Exhaust status 

1回/日

 

Once/day 

排気口が閉ざされていないか

 

Is the exhaust port unclogged? 

本体の振動

 

Vibrations of main body 

1回/日

 

Once/day 

異常振動、異常音がないか

 

設置レベルは出ているか

 

Are no abnormal vibrations or sounds 
generated? 
Is the installation level correct?

 

フィルタの取り付け状態

 

Filter installation status 

1回/月

 

Once/month 

フィルタ取り付けが緩んでいないか

 

Are the filters installed securely? 

風量不足状態

 

(吸引力確認)

 

Insufficient airflow lamp

 

status 

(Suction force check) 

運転時

 

During operation 

吸込みホース端の吸引力は適切か

 

風量不足ランプが点灯していないか

 

Does the suction hose end offer proper 
suction force? 
Is the clogging indicator lamp extinguished?

 

 

 

過負荷により、ヒューズが切れた場合は、ヒューズを交換してください。

 

When the fuse is blown out by excessive current generated by a 

trouble in the internal equipment, replace it.

 

交換ヒューズ  (各 2 個)  Applicable fuse  ×  2 

CBA-080AT2-HI 

250V 8A 

CBA-080AT2-HI

-T,-CE

 

250V 5A 

CBA-500AT2-HC 

250V 10A 

CBA-500AT2-HC 

-T,-CE

 

250V 5A 

CBA-1200AT2-HI-V1 

250V 10A 

CBA-1200AT2-HI-V1

 

(-T,-CE) 

250V 10A 

CBA-2000AT2-HI-V1 

250V 10A 

CBA-2000AT2-HI-V1    (-T,-CE) 

250V 10A 

ヒューズボックスは、

 

引き抜くことができません

 

It is impossible to pulled 
out the fuse box. 
 

先の細いもので引き出して下さい

Pull it out with the thin thing of 
tip. 

 

黒いボックスを引き出し、 
中に入っているヒューズを交換してください 

Pull the black box provided on the MAIN POWER switch, 
and replace the fuse. 

 

ヒューズは、主電源の下にあります。 

The fuse is accommodated inside the black box 
provided on the MAIN POWER switch. 

CBA-500AT2-HC 

Summary of Contents for CBA-080AT2-HI

Page 1: ...safely for a long time and enjoy its full performance Symbols used in this manual WARNING This symbol indicates actions that should not be performed in any case or actions that may lead to a serious...

Page 2: ...benzene kerosene paint etc Explosive dust Aluminum magnesium titanium zinc epoxy etc Dust containing sparks Dust containing sparks generated by high speed cutters grinders welding machines etc Fire so...

Page 3: ...AT2 panel 8 4 3 Remote connector 11 4 4 Confirmation before operation 11 4 5 Operation procedure 11 5 Remote Cable Sold Separately 12 5 1 Electrical circuit diagram 12 5 2 Color and signal of each wir...

Page 4: ...utdoors 0 40 80 Install the product in a place without dew condensation at room temperature ambient temperature 0 to 40 C humidity 80 or less High temperature and dew condensation may cause electrical...

Page 5: ...ine Disassembly and modification may cause an electrical shock and injury Contact your dealer for internal inspection and repair 1 6 Disposal Dispose of the product properly as industrial wast 2 Confi...

Page 6: ...The remote cable is so designed as to be prevented from falling off Insert it securely with its dent facing downward Make sure to confirm pin positions Power cable The cable is different in each regi...

Page 7: ...Replacement flanges are sold separately Removal method 65 CBA 080AT2 HC 75 CBA 500 1200 AT2 HC Turn the flange counterclockwise to remove it Turning it to clockwise tightens the flange Diameter of ins...

Page 8: ...Operating the product with a different power supply may cause a failure 3 ON OFF 30 ON OFF Allow an interval of at least three minutes before turning the equipment ON or OFF If the equipment is turned...

Page 9: ...hts when the suction power decreases due to a factor such as an open front door a clogged exhaust filter or a blocked exhaust duct The lamp turns off when the cause of the problem is corrected Volume...

Page 10: ...lay that indicates operational pressure is decimal number from 2 to 3 Initial value is 2 Step by step mode is changed by pressing HI LO button unit kPa Operation level 220V 220V mode 230V 230V mode Ma...

Page 11: ...switch and confirm that the MAIN POWER indicator lamp of AT2 panel lights AT2 ON Press the ON switch to start operation Confirm that abnormal sounds such as metallic sounds are not generated Confirm t...

Page 12: ...nce 4 7k Temperature correction is not provided Reference example 3 5 6 33 0 1 F Attach a noise limiter Approximately 33 0 1 F to the output terminals Nos 1 2 and 3 When adding inductors such as relay...

Page 13: ...Copyright CHIKO AIRTEC CO LTD 2015 13...

Page 14: ...r short circuiting pins and short circuit pin to start operation Red white Remote control operation switching signal Short circuits the wires 4 and 8 to start remote operation The AT2 panel is disable...

Page 15: ...ire AT2 ON Lo Hi To change the capacity level using the buttons on the main unit when switching to remote operation check that pin is not shorted circuited then press and hold the ON button on the AT2...

Page 16: ...e filter grid frame should be located on the exhaust side Make sure to turn OFF the main power and disconnect the power plug from the electrical outlet to cut off the electricity before starting inspe...

Page 17: ...s into the clearance on the left and right sides between the filter case and the filter to remove the filter easily Remove the primary filter from the filter case The paper packing of the primary filt...

Page 18: ...w lamp status Suction force check During operation Does the suction hose end offer proper suction force Is the clogging indicator lamp extinguished When the fuse is blown out by excessive current gene...

Page 19: ...of several plugs in one outlet is not adopted 3 Confirm that the motor is not overheated by clogged filters Fuses are blown out 6 7 Replace fuses Refer to Fuse The suction force is deteriorated Filter...

Page 20: ...Copyright CHIKO AIRTEC CO LTD 2015 20 8 Indication of DANGER Labels 9 Electrical Circuit Diagram CE MODEL CBA 080AT2 HI CE...

Page 21: ...Copyright CHIKO AIRTEC CO LTD 2015 21 CBA 1200AT2 HC CE CBA 500AT2 HC CE...

Page 22: ...Copyright CHIKO AIRTEC CO LTD 2015 22 CBA 2000AT2 HI V1 CE...

Page 23: ...ingle phase 3 6 50 60 2 2 8 0 57 70 10 0 CBA 080AT2 HI CE 450 220 230 Single phase 3 6 50 60 2 2 9 1 10 4 57 70 10 0 CBA 500AT2 HC 450 100 115 Single phase 6 5 50 60 3 2 9 5 61 65 17 8 CBA 500AT2 HC T...

Page 24: ...months CHF 2525 50 CHF 3030 50 CHF 3030 50 CHF 3535 70 6 12 Exhaust filter 6 to 12 months CHF 2525 50 CHF 3030 50 CHF 3030 50 HEP 3535 69 V1 6 12 Exhaust filter 6 to 12 months HEP 2525 50 HEP 3030 69...

Page 25: ...emo about purchase Model Manufacturer s serial number Date of purchase Start of operation Your name Address Phone Person in charge LTD 562 0012 2 27 24 2 27 24 Hakushima Minoh City Osaka apan 562 0012...

Reviews: