説明

 

Description 

  ON

ボタン

 

ON button 

 

運転を開始します。

(

同時にボタン左上の緑ランプが点灯します

Press this button to start equipment operation.(The green lamp at the upper 
left corner of the button lights.) 

  OFF

ボタン

 

OFF button 

 

運転を停止します。

 

Press this button to stop equipment operation. 
3

秒間長押しすると、電圧設定モードに移ります。設定後、再度

3

秒間長押しすると

運転モードに変わります。

( CBA-080AT2-HI

-V1

-CE

のみ

Keep pressing this button for 3 seconds then move to VOLTAGE-SETTING 
mode. Pressing this button for 3 seconds during VOLTAGE-SETTING mode,   
VOLTAGE-SETTING mode finishes and go back to an operation mode. 
 

  Hi

 

/

 

Lo

ボタン

 

Hi/Lo buttons 

 

Lo

1

回押すごとに1レベル降下、又は設定電圧変更。

 

Lo:  Each  press  of  this  button  decreases  the  setting  by  1  level  or  changes 

Voltage-setting. 
Hi

1

回押すごとに

1

レベル上昇、又は設定電圧変更。

 

Hi:  Each  press  of  this  button  increases  the  setting  by  1  level  or  changes 
Voltage-setting. 

※設定電圧変更は

  CBA-080AT2-HI

-V1

-CE

のみ有効です。

 

 

Chnging Voltage-setting is only available for    CBA-080AT2-HI

-V1

-CE. 

 

圧力不足

 

Pressure down

 

 

Red 

異常をお知らせします 
Alerts when an abnormality occurs. 
●正面扉が開いた状態である、排気フィルタが目詰まりしている、排気ダクトが塞が
れている、などの理由で吸引力が低下した時に赤 LED ランプが点灯します。原因を
除去するとランプが消灯します。 

The red LED lamp lights when the suction power decreases due to a   

factor such as an open front door, a clogged exhaust filter, or a   
blocked exhaust duct. 
The lamp turns off when the cause of the problem is corrected. 

 

 

風量不足

 

Volume down

 

 

Red 

風量低下をお知らせします    Alerts then airflow decreases 
●フィルタ目詰まり、または小径配管等によって、吸引口が小さくなり風量が低下し
た際は、赤 LED ランプが点灯します。 

The  clogged  filter  ,  suction  port  of  the  small-diameter  piping  is  reduced, 

when the air flow rate is decreased, red LED lamp is lit. 

 

運転圧力表示

 

Operating 
Pressure 
Indication 

 

現在の運転圧力(kPa)を表示しています。 
Indicates the current operating pressure level(kPa). 
●気圧の変化や温度条件により停止状態の圧力表示は-0.2kPa~0.2kPa の範囲
で変化します。また、外部ノイズの影響により一時的に圧力数値が変化する場合が
あります。 

When  the  equipment  is  not  operating,the  pressure  indication  varies  from 

-0.2kPa  to  +0.2kPa  due  to  changes  in  the  atmospheric  pressure  and 
temperature. 
External  noise  may  also  cause  momentary  changes  of  the  indicated 
pressure level. 

 
●集塵を始める前に、能力レベルを最大値にし、運転圧力が必ず 5.0kPa 以下であ
ることを確認してください。 

Before  starting  the  equipment  for  dust  collection,increase  the  capacity 

level to maximum and confirm that the operating pressure is 5.0kPa or lower. 

●ホースの先端が細い場合は、圧力が上昇しますので、5.0kPa 以上となった場合
には、ホース径を変更する必要があります 

If the hose has a narrow tip,the pressure level will rise.If the pressure 

exceeds 5.0kPa,use a hose with a different diameter. 

 

 

能力レベルランプ

 

CapacityLevel Lamp 

 

Green 

能力レベルを表示します。

(

レベル

1

7) 

Indicates capacity leve.(Levels: 1 to 7) 
 

Summary of Contents for CBA-080AT2-HI

Page 1: ...safely for a long time and enjoy its full performance Symbols used in this manual WARNING This symbol indicates actions that should not be performed in any case or actions that may lead to a serious...

Page 2: ...benzene kerosene paint etc Explosive dust Aluminum magnesium titanium zinc epoxy etc Dust containing sparks Dust containing sparks generated by high speed cutters grinders welding machines etc Fire so...

Page 3: ...AT2 panel 8 4 3 Remote connector 11 4 4 Confirmation before operation 11 4 5 Operation procedure 11 5 Remote Cable Sold Separately 12 5 1 Electrical circuit diagram 12 5 2 Color and signal of each wir...

Page 4: ...utdoors 0 40 80 Install the product in a place without dew condensation at room temperature ambient temperature 0 to 40 C humidity 80 or less High temperature and dew condensation may cause electrical...

Page 5: ...ine Disassembly and modification may cause an electrical shock and injury Contact your dealer for internal inspection and repair 1 6 Disposal Dispose of the product properly as industrial wast 2 Confi...

Page 6: ...The remote cable is so designed as to be prevented from falling off Insert it securely with its dent facing downward Make sure to confirm pin positions Power cable The cable is different in each regi...

Page 7: ...Replacement flanges are sold separately Removal method 65 CBA 080AT2 HC 75 CBA 500 1200 AT2 HC Turn the flange counterclockwise to remove it Turning it to clockwise tightens the flange Diameter of ins...

Page 8: ...Operating the product with a different power supply may cause a failure 3 ON OFF 30 ON OFF Allow an interval of at least three minutes before turning the equipment ON or OFF If the equipment is turned...

Page 9: ...hts when the suction power decreases due to a factor such as an open front door a clogged exhaust filter or a blocked exhaust duct The lamp turns off when the cause of the problem is corrected Volume...

Page 10: ...lay that indicates operational pressure is decimal number from 2 to 3 Initial value is 2 Step by step mode is changed by pressing HI LO button unit kPa Operation level 220V 220V mode 230V 230V mode Ma...

Page 11: ...switch and confirm that the MAIN POWER indicator lamp of AT2 panel lights AT2 ON Press the ON switch to start operation Confirm that abnormal sounds such as metallic sounds are not generated Confirm t...

Page 12: ...nce 4 7k Temperature correction is not provided Reference example 3 5 6 33 0 1 F Attach a noise limiter Approximately 33 0 1 F to the output terminals Nos 1 2 and 3 When adding inductors such as relay...

Page 13: ...Copyright CHIKO AIRTEC CO LTD 2015 13...

Page 14: ...r short circuiting pins and short circuit pin to start operation Red white Remote control operation switching signal Short circuits the wires 4 and 8 to start remote operation The AT2 panel is disable...

Page 15: ...ire AT2 ON Lo Hi To change the capacity level using the buttons on the main unit when switching to remote operation check that pin is not shorted circuited then press and hold the ON button on the AT2...

Page 16: ...e filter grid frame should be located on the exhaust side Make sure to turn OFF the main power and disconnect the power plug from the electrical outlet to cut off the electricity before starting inspe...

Page 17: ...s into the clearance on the left and right sides between the filter case and the filter to remove the filter easily Remove the primary filter from the filter case The paper packing of the primary filt...

Page 18: ...w lamp status Suction force check During operation Does the suction hose end offer proper suction force Is the clogging indicator lamp extinguished When the fuse is blown out by excessive current gene...

Page 19: ...of several plugs in one outlet is not adopted 3 Confirm that the motor is not overheated by clogged filters Fuses are blown out 6 7 Replace fuses Refer to Fuse The suction force is deteriorated Filter...

Page 20: ...Copyright CHIKO AIRTEC CO LTD 2015 20 8 Indication of DANGER Labels 9 Electrical Circuit Diagram CE MODEL CBA 080AT2 HI CE...

Page 21: ...Copyright CHIKO AIRTEC CO LTD 2015 21 CBA 1200AT2 HC CE CBA 500AT2 HC CE...

Page 22: ...Copyright CHIKO AIRTEC CO LTD 2015 22 CBA 2000AT2 HI V1 CE...

Page 23: ...ingle phase 3 6 50 60 2 2 8 0 57 70 10 0 CBA 080AT2 HI CE 450 220 230 Single phase 3 6 50 60 2 2 9 1 10 4 57 70 10 0 CBA 500AT2 HC 450 100 115 Single phase 6 5 50 60 3 2 9 5 61 65 17 8 CBA 500AT2 HC T...

Page 24: ...months CHF 2525 50 CHF 3030 50 CHF 3030 50 CHF 3535 70 6 12 Exhaust filter 6 to 12 months CHF 2525 50 CHF 3030 50 CHF 3030 50 HEP 3535 69 V1 6 12 Exhaust filter 6 to 12 months HEP 2525 50 HEP 3030 69...

Page 25: ...emo about purchase Model Manufacturer s serial number Date of purchase Start of operation Your name Address Phone Person in charge LTD 562 0012 2 27 24 2 27 24 Hakushima Minoh City Osaka apan 562 0012...

Reviews: