5.2 

各線の色と信号について

Color and signal of each wire 

 

入力 

INPUT

   

・①,④

 

:接点入力(無電圧接点)  Contact input (no-voltage contact) 

・  ⑦

 

:アナログ入力(

0

5V

)   

Analog

 

input voltage (0 to 5V) 

                 

+5.0V

以上印加させないでください。

 

Do not apply voltage exceeding 

5.0V.

 

 

出力 

OUTPUT 

・③,⑤,⑥  :オープンコレクタ出力 

Open collector output 

絶対最大定格 

Absolute Maximum Ratings

  :電圧

(Voltage)

  :

50

V  ,電流(

Current

):

100 mA 

                          *推奨値:  定格の

1/2

以下

   

Recommended value: less than 1/2 of the rated 

 

②  :アナログ出力(

0

5V

)   

Analog output voltage (0 to 5V) 

 

7

番ピンの印加電圧閾値表>

 

能力レベル

 

Capacity level 

電圧

(DCV) 

Voltage(VDC) 

0.6

1.1 

1.2

1.7 

1.8

2.3 

2.4

2.9 

3.0

3.5 

3.6

4.1 

4.2

5.0 

      ※誤差が±

4%

ある為、電圧を設定する際は、各レベルの中点の                                                                                   

 

     

   

電圧を印加してください。         

 

           

When setting the voltage,apply a mid-point voltage value for 

                                                                         

 

                each level since the error range is 

±

4%. 

線色

 

 

Wire color

 

PIN

 

NO. 

信号名称 

  Signal

 

name 

 

役割 

  Role 

黒 

   

Black

 

 

運転入力信号 

 

Operation input signal 

遠隔信号

(

入力

Rem

o

te

 s

ig

n

a

ls

 

④⑧を短絡後、①を短絡して運転を開始します

 

After short-circuiting pins

and

⑧、

short-circuit pin

to start 

operation. 

/

 

  Red/white

 

 

遠隔操作切替信号

 

Remote-control operation 
switching signal 

④と⑧を短絡してリモート操作に移行させます

 

短絡するとタッチパネルの操作はできなくなります

 

Short-circuits the wires [4] and [8] to start remote operation. 

The AT2 panel is disabled while the wires [4] and [8] are 

short-circuited.

 

 

Yellow

 

 

能力レベル変更

 

Change capacity level 

⑦と⑧の間で、

0~5

Vの電圧を印加する事で能力レベル

を変更することが出来ます。

 

The capacity level can be changed by applying a 
voltage of 0 to 5V between pins 

and

/

 

 

Yellow /white

 

 

Gnd

 

 

/

 

Black/White

 

 

運転圧力信号

 

Operation pressure signal 

出力信号

 

 

O

u

tp

u

s

ig

n

a

ls

 

現在の運転圧力を取り出します

 

Transfers the current operation output. 

アナログ信号

  Analog signal

0

5V

 

インピーダンス

  Impedance

  (≧

4.7

kΩ)

 

 

Red

 

 

フィルタ目詰出力信号

 

Filter clogging output signal 
 

目詰まり信号を取り出します

 

Transfers the clogging signal. 

オープンコレクタ出力;

NPN 

Open collector output 

 

Green

 

 

運転出力信号

 

Operation output signal 

運転信号(ONランプ)を取り出します

 

Transfers the operation signal (ON indicator lamp). 

オープンコレクタ出力;

NPN 

Open collector output 

/

 

Green/White

 

 

圧力不足出信号

 

Pressure  down  signal  output 
signal 

圧力不足信号を取り出します

 

Transfers the ” pressure down “ signal   

オープンコレクタ出力

:NPN 

Open collector output 

0

電圧

(DC

V)

 

能力レベル

 

Summary of Contents for CBA-080AT2-HI

Page 1: ...safely for a long time and enjoy its full performance Symbols used in this manual WARNING This symbol indicates actions that should not be performed in any case or actions that may lead to a serious...

Page 2: ...benzene kerosene paint etc Explosive dust Aluminum magnesium titanium zinc epoxy etc Dust containing sparks Dust containing sparks generated by high speed cutters grinders welding machines etc Fire so...

Page 3: ...AT2 panel 8 4 3 Remote connector 11 4 4 Confirmation before operation 11 4 5 Operation procedure 11 5 Remote Cable Sold Separately 12 5 1 Electrical circuit diagram 12 5 2 Color and signal of each wir...

Page 4: ...utdoors 0 40 80 Install the product in a place without dew condensation at room temperature ambient temperature 0 to 40 C humidity 80 or less High temperature and dew condensation may cause electrical...

Page 5: ...ine Disassembly and modification may cause an electrical shock and injury Contact your dealer for internal inspection and repair 1 6 Disposal Dispose of the product properly as industrial wast 2 Confi...

Page 6: ...The remote cable is so designed as to be prevented from falling off Insert it securely with its dent facing downward Make sure to confirm pin positions Power cable The cable is different in each regi...

Page 7: ...Replacement flanges are sold separately Removal method 65 CBA 080AT2 HC 75 CBA 500 1200 AT2 HC Turn the flange counterclockwise to remove it Turning it to clockwise tightens the flange Diameter of ins...

Page 8: ...Operating the product with a different power supply may cause a failure 3 ON OFF 30 ON OFF Allow an interval of at least three minutes before turning the equipment ON or OFF If the equipment is turned...

Page 9: ...hts when the suction power decreases due to a factor such as an open front door a clogged exhaust filter or a blocked exhaust duct The lamp turns off when the cause of the problem is corrected Volume...

Page 10: ...lay that indicates operational pressure is decimal number from 2 to 3 Initial value is 2 Step by step mode is changed by pressing HI LO button unit kPa Operation level 220V 220V mode 230V 230V mode Ma...

Page 11: ...switch and confirm that the MAIN POWER indicator lamp of AT2 panel lights AT2 ON Press the ON switch to start operation Confirm that abnormal sounds such as metallic sounds are not generated Confirm t...

Page 12: ...nce 4 7k Temperature correction is not provided Reference example 3 5 6 33 0 1 F Attach a noise limiter Approximately 33 0 1 F to the output terminals Nos 1 2 and 3 When adding inductors such as relay...

Page 13: ...Copyright CHIKO AIRTEC CO LTD 2015 13...

Page 14: ...r short circuiting pins and short circuit pin to start operation Red white Remote control operation switching signal Short circuits the wires 4 and 8 to start remote operation The AT2 panel is disable...

Page 15: ...ire AT2 ON Lo Hi To change the capacity level using the buttons on the main unit when switching to remote operation check that pin is not shorted circuited then press and hold the ON button on the AT2...

Page 16: ...e filter grid frame should be located on the exhaust side Make sure to turn OFF the main power and disconnect the power plug from the electrical outlet to cut off the electricity before starting inspe...

Page 17: ...s into the clearance on the left and right sides between the filter case and the filter to remove the filter easily Remove the primary filter from the filter case The paper packing of the primary filt...

Page 18: ...w lamp status Suction force check During operation Does the suction hose end offer proper suction force Is the clogging indicator lamp extinguished When the fuse is blown out by excessive current gene...

Page 19: ...of several plugs in one outlet is not adopted 3 Confirm that the motor is not overheated by clogged filters Fuses are blown out 6 7 Replace fuses Refer to Fuse The suction force is deteriorated Filter...

Page 20: ...Copyright CHIKO AIRTEC CO LTD 2015 20 8 Indication of DANGER Labels 9 Electrical Circuit Diagram CE MODEL CBA 080AT2 HI CE...

Page 21: ...Copyright CHIKO AIRTEC CO LTD 2015 21 CBA 1200AT2 HC CE CBA 500AT2 HC CE...

Page 22: ...Copyright CHIKO AIRTEC CO LTD 2015 22 CBA 2000AT2 HI V1 CE...

Page 23: ...ingle phase 3 6 50 60 2 2 8 0 57 70 10 0 CBA 080AT2 HI CE 450 220 230 Single phase 3 6 50 60 2 2 9 1 10 4 57 70 10 0 CBA 500AT2 HC 450 100 115 Single phase 6 5 50 60 3 2 9 5 61 65 17 8 CBA 500AT2 HC T...

Page 24: ...months CHF 2525 50 CHF 3030 50 CHF 3030 50 CHF 3535 70 6 12 Exhaust filter 6 to 12 months CHF 2525 50 CHF 3030 50 CHF 3030 50 HEP 3535 69 V1 6 12 Exhaust filter 6 to 12 months HEP 2525 50 HEP 3030 69...

Page 25: ...emo about purchase Model Manufacturer s serial number Date of purchase Start of operation Your name Address Phone Person in charge LTD 562 0012 2 27 24 2 27 24 Hakushima Minoh City Osaka apan 562 0012...

Reviews: