background image

 

   

チコーエアーテック株式会社

 

CHIKO AIRTEC CO., LTD. 

 

 

取扱説明書(以下、本書といいます)の『製品使用上のご注意』の内容をよく理解し、本書をよく読んでか
ら操作してください。

 

Please  understand  well  the  contents  of  "Cautions  on  Product  Use"  of  Instruction  Manual 
(hereinafter referred to as “this manual”), and operate it after often reading this manual. 

 

本書はいつでも使用できるよう、大切に保管してください。

 

Please keep this manual carefully to be able to use it at any time. 

 

E

nglis

h

 

 
 

 

コンパクト集塵機

 

Dust Collector 

型式/

MODELS 

CBA-080AT3-HI(-V1) 

(100V) 

CBA-080AT3-HI(-V1)-T 

(200V) 

CBA-080AT3-HI(-V1)-CE  (220-230V) 
CBA-500AT3-HI(-V1) 

(100V) 

CBA-500AT3-HI(-V1)-T 

(200V) 

CBA-500AT3-HI(-V1)-CE  (220-230V) 
CBA-1200AT3-HI-V1 

(200V) 

CBA-1200AT3-HI-V1-CE 

(220-230V) 

CBA-2000AT3-HI-V1 

(200V) 

CBA-2000AT3-HI-V1-CE 

(220-230V) 

取扱説明書

 

Instruction Manual 

Summary of Contents for CBA-080AT3-HI

Page 1: ...n reading this manual 本書はいつでも使用できるよう 大切に保管してください Please keep this manual carefully to be able to use it at any time 日 本 語 English コンパクト集塵機 Dust Collector 型式 MODELS CBA 080AT3 HI V1 100V CBA 080AT3 HI V1 T 200V CBA 080AT3 HI V1 CE 220 230V CBA 500AT3 HI V1 100V CBA 500AT3 HI V1 T 200V CBA 500AT3 HI V1 CE 220 230V CBA 1200AT3 HI V1 200V CBA 1200AT3 HI V1 CE 220 230V CBA 2000AT3 HI V1 200V CBA 2000AT...

Page 2: ...working to achieve clean air with compact equipment while utilizing air technology effectively The CBA Series is an energy saving type clean box that realizes air technology in a compact body Please read this instruction manual thoroughly and handle this CBA Series machine correctly so that you can use it safely for a long time and enjoy its full performance 本文中の表記について About Notation 本書では 以下の表記に従っ...

Page 3: ... 12 3 1 1 設置 12 3 1 2 配線 配管 13 3 2 運転 13 3 3 初期圧登録 14 第 4 章 各種設定 モードセレクトモード 15 4 1 モードセレクトモードでの画面遷移 15 4 2 通信フォーマット設定モード 通信機能装備時 15 4 3 風量不足お知らせタイミング設定モード 16 4 4 電源電圧設定モード CBA 080AT3 HI CE のみ 16 4 5 その他の設定モード 17 4 5 1 時刻合わせモード 17 4 5 2 積算稼働時間リセットモード 17 4 5 3 設定値リセットモード 18 4 6 エラー履歴モード 18 第 5 章 保守 点検 19 5 1 フィルタの交換 19 5 1 1 1 次フィルタの交換 19 5 1 2 2 次フィルタの交換 20 5 1 3 排気フィルタの交換 20 5 1 4 モータ冷却用排気フィルタの交換 ...

Page 4: ... 2 ピンアサイン 28 6 1 3 リモート操作 29 6 2 通信機能 29 6 2 1 RS485 通信 29 6 2 2 イーサネット 29 6 3 脱着フランジ CBA 2000AT3 HI V1 を除く 29 第 7 章 付録 30 7 1 仕様 30 7 2 消耗品リスト 30 7 3 電気回路図 31 7 3 1 CBA 080AT3 HI 31 7 3 2 CBA 500AT3 HI 31 7 3 3 CBA 1200AT3 HI V1 32 7 3 4 CBA 2000AT3 HI V1 32 ...

Page 5: ...安全な場所で 温度 10 60 湿度 80 以下の範囲としてくだ さい 1 3 設置時のご注意 警 告 引火性 爆発性 腐食物質の霧 煙 ガスが滞留している場所や これらの付近 に設置しないでください 注 意 本機は 屋内クリーンルーム内または清浄度の高い工場に設置することを前提と した構造となっていますので 屋外などには設置しないでください 狭い吸引口で使用しないでください 吸引口が狭い 圧力が高い 状態で使用し続けるとモータが冷却出来ず高温にな る恐れがあります 回転機器が内蔵されていますので 水平で振動のない場所に設置してください 常温 周囲温度 0 40 湿度 80 以下 で 結露しない場所に設置してください 高温 結露は 電気部品の故障 感電の原因になります 吸引雰囲気温度 集塵対象の粉塵をとりまく周囲の温度 が高いとモータ能力の 低下 故障の原因になりますので十分考慮してくださ...

Page 6: ... 感電の原因になります 本機の仕様と異なる電源で使用しないでください 粉塵爆発のおそれのない乾いた粉塵の吸引に使用してください アース線は必ず接続して使用してください 注 意 運転中は移動させないでください 汚染度Ⅱ 製造工場 の場所で使用してください 過電圧カテゴリーが区分Ⅱ 産業用装置など の電源で使用してください 停電時は 主電源スイッチを OFF にしてください 停電復旧時に けが 装置破損の原因になります フィルタは正しく取り付けて使用してください フィルタが取り付けられていなかったり 目詰まりや破損した状態で運転すると モータ内へ異物が混入し 故障の原因となります 1 5 その他のご注意 警 告 本機を分解 改造しないでください 感電 けがの原因になります 内部の点検や修理はお買い上げになった販売店にご連絡ください 設置 接続 運転 操作 点検 故障診断の作業は 取扱説明書の内...

Page 7: ...第 1 章 製品使用上のご注意 CMN004 005 5 日 本 語 1 6 危険シールの貼付位置 高電圧警告シール 高温警告シール 分解禁止シール ネームプレート 分解禁止シール 高電圧警告シール ネームプレート 高温警告シール ...

Page 8: ...します 1 2 次フィルタ 電気部品を粉塵から守ります 1 排気フィルタ 排気をクリーンにします 1 排気 HEPA フィルタ 排気をクリーンにします V1 仕様のみ 1 モータ冷却用排気フィルタ 排気をクリーンにします CBA 1200AT3 のみ 1 脱着フランジ 吸気ダクトを接続します CBA 2000AT3 を除く 1 電源ケーブル 3m 電源コンセントに接続します 電源仕様により形状が異なり ます 100V 仕様 1 1 200V 仕様 T 仕様 1 220 230V 仕様 CE 仕様 1 取扱説明書 本機の使用方法を説明しています 本書 1 1 100 115V の地域でお使い頂けます ...

Page 9: ...AT3 CBA 500AT3 CBA 2000AT3 番号 名称 働き 排気口扉 排気フィルタを収納しています AT3 パネル 操作パネル 本機を操作します 電源コネクタ 電源ケーブルを接続します ヒューズ BOX ヒューズを収納します 主電源スイッチ 本機の電源の入切を行います リモートコネクタ リモートケーブル 別売 を接続します 吸気側フィルタケース 1 次 2 次フィルタを収納しています 吸込み口 脱着フランジ 1 吸気ダクトを接続します 1 CBA 2000AT3 は脱着フランジを使用できません ...

Page 10: ...T3 番号 名称 働き 排気口扉 排気フィルタを収納しています AT3 パネル 操作パネル 本機を操作します 電源コネクタ 電源ケーブルを接続します ヒューズ BOX ヒューズを収納します 主電源スイッチ 本機の電源の入切を行います リモートコネクタ リモートケーブル 別売 を接続します 吸気側フィルタケース 1 次 2 次フィルタを収納しています 吸込み口 脱着フランジ 吸気ダクトを接続します モータ冷却口カバー モータ冷却用排気フィルタを収納しています ...

Page 11: ...ードセレクトモード 15 ページ 異常ランプ 運転を停止するエラーが発生したときは 赤色ランプが点灯し 運転を継続するエラー 警告が発生したときは 赤色ランプが点滅します ボタン 運転中は ボタンを 1 回押すごとに能力が 1 レベル降下 上昇 しま す モードセレクトモード時は ボタンを 1 回押すごとにカーソルが 1 つ左 右 に移動します OFF ボタン 運転を停止します 停止中に3秒間長押しすると 登録した初期圧をクリアします 3 3 初期圧登録 14 ページ ON ボタン 運転を開始します ENTER ボタン 運転中は 3 秒間長押しすると初期圧登録に移行します 3 3 初期圧登録 14 ページ モードセレクトモード時は 設定項目の選択と数値データを決定します 第 4 章 各種設定 モードセレクトモード 15 ページ MODE SELECT ボタン 停止中は モードセレクトモード...

Page 12: ...ィスプレイ表示 2 4 1 モードについて 2 4 2 停止中の表示 ボタンで表示を切り替えることができます 停止中 通常モード 運転中 ON ボタン OFF ボタン モードセレクトモード 15 ページ モードセレクトボタン 初期圧登録 14 ページ ENTER ボタン 3 秒押し 主電源スイッチ ON 初期圧登録クリア 14 ページ OFF ボタン 3 秒押し Ver ID Battery Date Time プログラムバージョン RS485 通信用局番 電池残量 日付 時間 時刻合わせモード 17 ページ ...

Page 13: ...本 語 2 4 3 運転中の表示 ボタンで表示を切り替えることができます OP kPa SP kPa DP kPa EP kPa 外部圧 吸込圧 差圧 排気圧 Blower ブロア周辺温度 Motor rpm モータ回転数 現在運転中のモータの回転数を表示します Runtime h 積算稼働時間 リセット可 リセット後からの稼働時間を表示します 積算稼働時間リセットモード 17 ページ Total h 実働時間 リセット不可 トータルの稼働時間を表示します ...

Page 14: ...いこと ボタン電池絶縁シートの取り外し ボタン電池の絶縁シートを取り外す際には 通電状態で行ってください 1 本機を使用する前にボタン電池の絶縁シート を取り外してください 2 吸気側フィルタケースのパッチン錠 2 ヶ所 を 外します 3 吸気側フィルタケースを開きます 4 電池カバー部から絶縁シートを矢印の方向 左 または下 に引き抜きます 機種により絶縁シートを引き抜く方向が異なり ます 注 意 本体を通電せず絶縁シートを引き抜くと 著しく電池が消耗することがあります メ モ ボタン電池は主電源スイッチが OFF のときに消費されます 主電源 ON 時 1 μA 以下 主電源 OFF 時 40 50 μA 電池寿命 参考値 約 2 年 は 使用状況によって変わります 目安としてください 吸気側フィルタケース 電池カバー パッチン錠 電池カバー 絶縁シート 絶縁シート ...

Page 15: ...ります 本機の電源は 単相電源です 供給電圧の許容範囲は 10 です 1 電源コードの本体差し込みプラグを本機の電源コネクタに接続します 2 電源コードの電源側を電源に接続します 配管 1 脱着フランジを右にしっかり回して吸気口に取 り付けます 2 吸気配管 別途ご準備 を脱着フランジに接続 します 3 2 運転 1 主電源スイッチを ON にします ディスプレイにプログラムバージョンと RS485 通信用の ID 番号が表示されます 2 AT3 パネルの ON ボタンを押します 装置の運転が開始されます 3 異常音がないことと 適切な吸引であること を確認します 4 ボタンで吸引レベルを設定します 能力レベルランプ 1 7 で吸引能力が表示 されます 重 要 適切な配管で運転してください 配管はできるだけ短くし 配管口径は狭くしすぎないでください 脱着フランジ Ver ID ボタン 能力...

Page 16: ...ECT ボタンを押すと通常動作に戻ります 5 能力レベル 1 から 7 まで順番に運転し 各能力レベルの差圧を自動取得します 初期圧力の取得動作中は ディスプレイに Initial DP Check と 能力レベルと差圧 が交互に表示されま す 6 登録が完了すると ディスプレイに Initial DP Entry と表示されて通常動作に戻ります 重 要 フィルタが必ず新品の状態で行ってください 初期圧力登録後 配管を変えた場合やフィルタを全て交換された場合 排気フィルタ除 く は 再度 初期圧力を更新登録してください 初期圧力が登録されていないと初期圧力未登録警告 WARN6 が表示されます 停止中に OFF ボタンを 3 秒間長押しすると 登録した初期圧をクリアします 初期圧登録クリア 1 停止中に OFF ボタンを 3 秒間長押しします ディスプレイに Initial DP Clr ...

Page 17: ...57600bps 115200bps 9600bps ビット長とパリティ ビット長 8bit パリティなし ビット長 8bit パリティ奇数 ビット長 8bit パリティ偶数 ビット長 9bit パリティなし ビット長 8bit パリティなし ストップビット ストップビット 1 ビット ストップビット 2 ビット ストップビット 1 ビット 1 モードセレクトモードに移行します 2 ボタンを押して通信フォーマット設定モード Com Setting に移行します 3 ENTER ボタンを押します 通信局番の確認画面になり 現在の設定内容が表示されます 4 ボタンを押して設定する項目に移行します Com Setting Volume Down ST Other Setting Error Data 通信フォーマット設定モード 15 ページ 風量不足お知らせタイミング設定モード 16 ページ そ...

Page 18: ...す 標準出荷設定値は 50 で 3 Down to 50 が表示されます 4 ボタンを押して 30 70 の間で選択します 設定値を下げると風量不足お知らせのタイミングが遅くなり 設定値を上げると早くなります 5 ENTER ボタンを押して設定内容を決定します 6 終了する場合は MODE SELECT ボタンを押して通常モードに戻ります 4 4 電源電圧設定モード CBA 080AT3 HI CE のみ 供給されている電源電圧を 220V と 230V から選択してください 選択された電源電圧に応じて 風量不足を判定するしきい値を切り替えます 1 モードセレクトモードに移行します 2 ボタンを押して電源電圧設定モード Supply Voltage に移行します 3 ENTER ボタンを押します 現在の設定内容が表示されます 標準出荷設定値は 220V で 1 220V が表示されます 4...

Page 19: ...ER ボタンを押します 日付の設定画面になります 5 ボタンを押して数値を変更します 6 ENTER ボタンを押して数値を決定します 年 月 日の順に設定します 7 日付が設定されると 時刻の設定画面になります 8 ボタンを押して数値を変更します 9 ENTER ボタンを押して数値を決定します 時 分 秒の順に設定します 10 終了する場合は MODE SELECT ボタンを押して通常モードに戻ります 4 5 2 積算稼働時間リセットモード 積算稼働時間 Runtime をリセットします 1 モードセレクトモードに移行します 2 ボタンを押してその他の設定モード Other Setting に移行します 3 ENTER ボタンを押します Time Adjust が表示されます 4 ボタンを押して 表示を Runtime Reset にします 5 ENTER ボタンを押します Reset R...

Page 20: ...されます 4 ボタンを押して 表示を Setting Reset にします 5 ENTER ボタンを押します 1 YES と表示され 設定値をリセットするか確認されます リセットする場合は ENTER ボタンを押してください 6 再確認のため 1 START と表示されます 7 ENTER ボタンを押すと設定値がリセットされ 通常モードに移行します 4 6 エラー履歴モード 4 件分のエラー履歴を確認することができます エラー履歴は主電源スイッチを OFF するとクリアされます 1 モードセレクトモードに移行します 2 ボタンを押してエラー履歴モードに移行します 3 ENTER ボタンを押します 直近で発生したエラーNo と発生したときの積算稼働時間が表示されます 4 ボタンを押すと 新しい順に 4 件分のエラー履歴が表示されます 5 終了する場合は MODE SELECT ボタンを押して...

Page 21: ...を交換してください 5 1 1 1 次フィルタの交換 重 要 1 次フィルタの交換は 吸気側フィルタケースを開くことができる十分なスペースがある場 所で行ってください 1 吸気側フィルタケースのパッチン錠 2 ヶ 所 を外します 2 吸気側フィルタケースを開け 2 次フィル タを取り外します 3 1 次フィルタを取り外します 1 次フィルタはフィルタケースのフランジ に フィルタ紙パッキン部を差し込んでい ます メ モ 1 次フィルタが取り外しにく い場合は 吸気側フィルタ ケースと 1 次フィルタのスキ マ 左右 にマイナスドライ バを差し込んで取り外してく ださい 吸気側フィルタケースは 本体から取り外すこともで きます 4 新しい 1 次フィルタを取り付け 2 次フィ ルタを元通りに取り付けます パッチン錠 吸気側フィルタケース 2 次フィルタ 1 次フィルタ ...

Page 22: ...てください 1 吸気側フィルタケースのパッチン錠 2 ヶ 所 を外します 2 吸気側フィルタケースを開け 2 次フィルタ を取り外します 3 新しい 2 次フィルタを取り付けます 4 吸気側フィルタケースを閉じ パッチン錠 2 ヶ所 で固定します 5 1 3 排気フィルタの交換 注 意 フィルタの取り付け時は 裏 表を間違えないでください フィルタ格子の枠が排気側です 重 要 排気フィルタの交換は 十分なスペースがある場所で行ってください 1 排気口扉のパッチン錠 左右の 2 ヶ所 を 外し 排気口扉を取り外します 2 排気フィルタを取り出します パッチン錠 吸気側フィルタケース 2 次フィルタ パッチン錠 排気口扉 排気フィルタ ...

Page 23: ...気フィルタに交換し ます 3 モータ冷却口カバーを元通りに取り付けま す 5 2 ヒューズの交換 内部機器のトラブルによる過電流でヒューズが切れた時は ヒューズ 1 個 を交換してください ヒューズは 電源スイッチの左側の黒いボックス内にあります ヒューズの交換の際には 弊社規定のヒューズをお使いください 規定ヒューズ Littell fuse 製 218 シリーズ 250V 10A CBA 080 500 15A CBA 1200 2000 1 ヒューズボックスのカバーを開きます カバーは取り外すことはできません 2 マイナスドライバなどの先の細いものでヒ ューズボックスを取り出します 3 ヒューズボックス内のヒューズを交換しま す ネジ ネジ モータ冷却口カバー モータ冷却用排気フィルタ カバー ヒューズ ...

Page 24: ...い 本体を通電せずに電池を交換すると著しく電池が消耗することがあります 1 本体を通電して下さい 2 吸気側フィルタケースを開きます 3 電池カバーのネジ 2 個 を外し 電池カバ ーを取り外します 4 爪を右に押し ボタン電池を取り外します 5 新しいボタン電池に交換します 6 電池カバーを元通りに取付けます 7 本体の電源を遮断して下さい 5 4 日常点検 点検項目 頻 度 点検内容 フィルタケース 運転前 完全に閉じているか 吸込口 運転前 吸込口が閉ざされていないか 排気の状態 1 回 1 日 排気口が閉ざされていないか 操作パネルの状態 1 回 1 日 エラーや警告が表示されていないか ネジ 電池カバー ボタン電池 爪 ...

Page 25: ...るときは 優 先順位の高いものが表示されます 表示データ 交互に表示 エラーNo 2 MODE SELECT ボタンを押し エラー履歴モ ードに移行します 複数のエラー 警告が発生しているときは エ ラーNo の左側に件数が表示されます 3 複数のエラー 警告が発生しているときは ボタンを押して エラーNo を確認します 4 ディスプレイに表示されているエラーNo に対 応した処置を行います 5 5 2 エラー 警告一覧 24 ページ 5 MODE SELECT ボタンを押し エラークリアモ ードに移行します 6 エラー 警告を解除する場合は ENTER ボタンを押して通常モードに戻ります エラー 警告を解除しない場合は MODE SELECT ボタンを押して通常モードに戻ります エラー 警告を解除しなかった場合 運転を継続するエラー 警告の場合 全てのボタンが有効です 運転を停止するエラ...

Page 26: ...にお問い合わせくださ い ERR08 通信異常 BCC 判定が不一致 点滅 運転 継続 当社にお問い合わせくださ い WARN1 内部温度上昇 ブロア周辺温度が異常 判定閾値に近い 点滅 運転 継続 5 6 故障と思ったら の の対策方法に従って処置を 行ってください 25 ペ ージ WARN2 フィルタ交換 時期超過 風量低下状態で一定時 間以上運転継続 点滅 運転 継続 5 6 故障と思ったら の の対策方法に従って処置を 行ってください 25 ペ ージ WARN3 圧力 吸込 不 足 吸込圧が低い 点滅 運転 継続 5 6 故障と思ったら の の対策方法に従って処置を 行ってください 25 ペ ージ WARN4 風量不足 フィルタ目詰まりによる 風量低下 点滅 運転 継続 5 6 故障と思ったら の の対策方法に従って処置を 行ってください 25 ペ ージ WARN5 排気圧力異常 ...

Page 27: ...ッドが働いている可能性がありますの で 主電源を切り 30 分経過してから 運転を 開始してください 1 次フィルタまたは 2 次フィルタが取り付けら れていない 1 次フィルタと 2 次フィルタを正しく取り付け る パッチン錠が外れてい る パッチン錠を確実に取りける 吸引力の低下 フィルタの目詰まり フィルタを交換する 5 1 フィルタの交換 19 ページ 目詰まりを放置すると 粒子の吹きもれ や 集塵機内部の温度上昇 の原因となります 配管 吸込口の詰り 配管の詰りや吸込口が塞がれていないか確 認する 2 モータ故障を起こして いる 修理を依頼してください モータ交換になります 粒子の吹きもれ フィルタの取り付け不 良 フィルタを取り付け直す 5 1 フィルタの交換 19 ページ フィルタの破損 寿命 フィルタを交換する 5 1 フィルタの交換 19 ページ フィルタの目詰まり フィ...

Page 28: ...が可能になり AT3 パネルの通常操作は行えません ピン 圧力アナログ信号を出力します ピン インダクタ リレー等 を付加する場合は ノイズリミッタ 約 33Ω 0 1μF またはダイオード等 を取り付けてください 運転入力信号 遠隔操作切替信号 運転圧力信号 フィルタ目詰信号 運転信号 異常信号 能力レベル変更入力信号 耐圧 DC 50V 100mA 以下でご使用下さい GND DC 1 5V インダクタ リレー等 を付加する場合 は 出力端子 端子番号 に ノイ ズリミッター 約 33Ω 0 1μ F を付けて下 さい LOAD LOAD DC 0 5V GND LOAD LOAD LOAD ...

Page 29: ...CMN004 005 27 日 本 語 接続例 ピン 入力 ピン アナログ出力 ピン オープンコレクタ出力 ピン 入力 参考回路 電圧を印加しないでください 参考回路 計測器等 出力電圧 1 5V 0 2V 状態 ポイント B C ON HIGH LOW OFF LOW HI Z ピンが LOW の時 負荷に電 流が流れます 定格を超えないよ うに保護回路を追 加してください 推奨 DC 電圧 電流 最大定格の 1 2 以 下 参考回路 ...

Page 30: ...出力します アナログ信号 1 5V インピーダンス 4 7kΩ 赤 フィルタ目詰出力信号 3 目詰まり信号を出力します オープンコレクタ出力 NPN 緑 運転出力信号 3 運転信号 ON ランプ を出力します オープンコレクタ出力 NPN 緑 白 異常信号 3 異常信号を出力します オープンコレクタ出力 NPN 目詰まり信号 WARN2 WARN4 WARN5 の場合 異常信号 全ての ERR の場合 1 接点入力 無電圧接点 2 アナログ入力 0 5V 5 0V 以上印加させないでください ピンの印加電圧閾値表 能力レベル 電圧 DCV 1 0 6 1 1 2 1 2 1 7 3 1 8 2 3 4 2 4 2 9 5 3 0 3 5 6 3 6 4 1 7 4 2 5 0 誤差が 4 あるため 電圧を設定する場合は 各レベルの中点の電圧を印加してください 3 オープンコレクタ出力 絶対...

Page 31: ...ト 型式 RS 485 又は RS EN を使用する事で 運転 ON OFF や フィルタ目詰ま り等の情報を取り出す事が可能です 6 2 1 RS485 通信 設定方法は 4 2 通信フォーマット設定モード 通信機能装備時 を参照してください 4 2 通信フォーマット設定モード 通信機能装備時 15 ページ 6 2 2 イーサネット 詳細については 別途購入されたイーサネットの取扱説明書を参照してください 6 3 脱着フランジ CBA 2000AT3 HI V1 を除く ご使用の環境に応じて吸込み口径の変更が必要な場合は 工具なしでフランジを交換することができます 交換可能なフランジ径 型式 フランジ径 mm φ38 φ50 φ65 Φ75 CBA 080AT3 FRJ D 38 35 92 FRJ D 50 35 92 FRJ D 65 35 92 CBA 500AT3 FRJ D 3...

Page 32: ...0Hz 5 5m3 min 13 50kPa 60 77 dB 26 7kg CBA 1200AT3 HI V1 CE 220 230V 単相 9 5A 12 50kPa CBA 2000AT3 HI V1 1200W 200V 単相 9 5A 50 60Hz 6 0m3 min 9 60kPa 67 70 dB 31 0kg CBA 2000AT3 HI V1 CE 200 230V 単相 9 5A 1 騒音値は吸込み口にホースを接続し 本機から 1m 離れて A スケール dB で測定しています 2 100 115V の地域でご使用頂けます 7 2 消耗品リスト 品名 交換周期 1 CBA 080AT3 HI CBA 500AT3 HI CBA 1200AT3 HI V1 CBA 2000AT3 HI V1 1 次フィルタ 1 3 ヵ月 FB 25 FB 30 FB 30 FB 700...

Page 33: ...第 7 章 付録 CMN004 005 31 日 本 語 7 3 電気回路図 7 3 1 CBA 080AT3 7 3 2 CBA 500AT3 これらの基板は説明 のため反体面を透視 した状態で記載して これらの基板は説明 のため反体面を透視 した状態で記載してい ます これらの基板は説明 のため反体面を透視 した状態で記載してい ます ...

Page 34: ...第 7 章 付録 32 7 3 3 CBA 1200AT3 7 3 4 CBA 2000AT3 これらの基板は説明 のため反体面を透視 した状態で記載して います これらの基板は説明 のため反体面を透視 した状態で記載して います ...

Page 35: ...環境以外での使用による故障または損傷の場合 弊社および弊社指定の販売店以外で修理 改造 分解等をした場合 使用中に生じたキズ 汚れなどの外観上の変化の場合 消耗品 付属品の交換および弊社指定以外の部品を使用した場合 お買い上げ後の落下 および運送上の事故による故障または損傷の場合 火災 塩害 ガス害 地震 風水害 落雷 電圧異常およびその他の天変地異を原因とする故障または損 傷の場合 修理について 出張修理のご希望の場合 出張料金は 保証期間内外を問わず有料となります 修理の都合により 修理時に改良部品を使用する場合がございます 本機の故障による損害 データの抹消による損害 その他本機の使用により生じた損害について 弊社は一 切その責任を負いかねますので ご了承ください お買い上げメモ 形 式 製造番号 購入年月日 運転開始日 年 月 お客様お名前 住所 電話 担当者 ...

Page 36: ... Pressures 46 Chapter 4 Configuring Settings MODE SELECT Mode 47 4 1 Screen Transitions in MODE SELECT Mode 47 4 2 Communication Format Setting Mode When Equipped with Communication Function 47 4 3 Air Volume Down Alert Timing Setting Mode 48 4 4 Supply Voltage Setting Mode CBA 080AT3 HI CE only 48 4 5 Other Setting Mode 49 4 5 1 Clock Calibration Mode 49 4 5 2 Accumulated Run Time Reset Mode 49 4...

Page 37: ...Remote Operation 61 6 2 Communication Function 61 6 2 1 RS485 Communication 61 6 2 2 Ethernet 61 6 3 Removable Flange Except for CBA 2000AT3 HI V1 61 Chapter 7 Appendix 62 7 1 Specifications 62 7 2 Consumables List 62 7 3 Electrical Diagram 63 7 3 1 CBA 080AT3 63 7 3 2 CBA 500AT3 63 7 3 3 CBA 1200AT3 64 7 3 4 CBA 2000AT3 64 ...

Page 38: ... explosive or corrosive mist smoke or gases CAUTION This device is designed for installation in a cleanroom or a clean factory Avoid installation in other areas such as outdoors Ensure a wide suction port If the device is used continuously with a narrow suction port i e at high pressure the motor may become hot as it cannot be cooled Install the device in a horizontal vibration free location as it...

Page 39: ...out potential dust explosion Be sure to connect the ground wire CAUTION Do not move the device while in operation Use the device in locations of pollution degree II manufacturing plant Use a power supply of overvoltage category II industrial device etc Turn off the main power switch in case of power outage Injury or device damage can occur when power returns Ensure that filters are installed corre...

Page 40: ...s CMN004 005 37 English 1 6 Safety Label Locations High voltage warning label High temperature warning label Do not disassemble label Nameplate Do not disassemble label High voltage warning label Nameplate High temperature warning label ...

Page 41: ...eans exhaust 1 Exhaust HEPA filter Cleans exhaust V1 version only 1 Motor cooling exhaust filter Cleans exhaust CBA 1200AT3 only 1 Removable flange Connects a suction duct Except for CBA 2000AT3 1 Power cable 3 m Connects to the power outlet Shaped differently depending on power supply specifications 100V version 1 1 200 V version T version 1 220 230 V version CE version 1 Instruction manual Provi...

Page 42: ...T3 panel operation panel Operates the device Power connector Connects the power cable Fuse box Contains a fuse Main power switch Turns on off power to the device Remote connector Connects a remote cable optional Suction side filter case Contains primary and secondary filters Suction port removable flange 1 Connects a suction duct 1 The CBA 2000AT3 cannot use a removable flange ...

Page 43: ...e device Power connector Connects the power cable Fuse box Contains a fuse Main power switch Turns on off power to the device Remote connector Connects a remote cable optional Suction side filter case Contains primary and secondary filters Suction port removable flange Connects a suction duct Motor cooling port cover Contains a motor cooling exhaust filter ...

Page 44: ...h pressing of the Left or Right arrow button changes the suction power to the next lower or higher level During MODE SELECT mode each pressing of the Left or Right arrow button moves the cursor left or right to the next position OFF button Stops the operation During stoppage holding this button down for three seconds clears the registered initial pressure 3 3 Registering Initial Pressures page 46 ...

Page 45: ...le through indications Normal mode ON button OFF button Page 46 MODE SELECT button Page 46 ENTER button Held down for 3 sec Main power switch ON Page 46 OFF button Held down for 3 sec During stoppage During operation Ver ID Battery Date Time Program version RS485 communication ID Remaining battery level Date Time Clock calibration mode Page 49 ...

Page 46: ...tion pressure Differential pressure Exhaust pressure Blower C Temperature around blower Motor rpm Motor rotational frequency Indicates the rotational frequency of the currently running motor Runtime h Accumulated run time resettable Indicates run time accumulated since the last resetting Accumulated run time reset mode Page 49 Total h Actual run time not resettable Indicates the total run time ...

Page 47: ... electricity 1 Before using the device remove the insulation sheet from the button battery 2 Release the two snap locks for suction side filter case 3 Open the suction side filter case 4 Pull the insulating sheet in the arrow direction leftward or downward off the battery cover The direction for pulling off the insulating sheet depends on the device model Note The button battery drains when the ma...

Page 48: ...e until it is secured on the suction port 2 Connect the suction tube to be prepared separately to the removable flange 3 2 Operation 1 Turn on the main power switch The display indicates the program version and the ID for RS485 communication 2 Press the ON button on the AT3 panel The device starts operation 3 Check that abnormal noise is not generated and the suction is appropriate 4 Set a desired...

Page 49: ...the Initial DP Check message and the suction power level and differential pressure values 6 When the registration completes the display shows the Initial DP Entry message and the device returns to normal operation IMPORTANT Ensure that the filters are new Update registered initial pressures once again if piping is changed or all filters are replaced except for the exhaust filter after registration...

Page 50: ...Communication station number 1 to 25 1 Baud rate 9600 bps 19200 bps 38400 bps 57600 bps 115200 bps 9600 bps Bit length and parity Bit length 8 bits with no parity Bit length 8 bits odd parity Bit length 8 bits even parity Bit length 9 bits with no parity Bit length 8 bits with no parity Stop bit Stop bit 1 bit Stop bit 2 bits Stop bit 1 bit 1 Move to the MODE SELECT mode 2 Press the Up Down arrow ...

Page 51: ... later and vice versa 5 Press the ENTER button to determine the setting 6 To exit this mode press the MODE SELECT button to return to normal mode 4 4 Supply Voltage Setting Mode CBA 080AT3 HI CE only Select your supply voltage 220 or 230 V The air volume low threshold switches with the selected supply voltage 1 Move to the MODE SELECT mode 2 Press the Up Down arrow buttons to move to the supply vo...

Page 52: ...the value Set the value in this order year month and day 7 After the date is set the time setting screen appears 8 Press the Up Down arrow buttons to change the value 9 Press the ENTER button to determine the value Set the value in this order hours minutes and seconds 10 To exit this mode press the MODE SELECT button to return to normal mode 4 5 2 Accumulated Run Time Reset Mode This mode resets t...

Page 53: ...nfirmation to reset setpoints To reset press the ENTER button 6 The display shows 1 START for reconfirmation 7 Press the ENTER button to reset the setpoints and move the device to normal mode 4 6 Error History Mode The error history allows for checking four occurrences of errors The error history is cleared by turning off the main power switch 1 Move to the MODE SELECT mode 2 Press the Up Down arr...

Page 54: ...n the suction side filter case 1 Release the two snap locks for suction side filter case 2 Open the suction side filter case and remove the secondary filter 3 Remove the primary filter The primary filter has its filter paper packing inserted in the flange on the filter case Note If the primary filter is hard to remove use a flathead screwdriver inserting the screwdriver into the space right or lef...

Page 55: ...er case and secure it with the two snap locks 5 1 3 Replacing the Exhaust Filter CAUTION Avoid installing the filter inside out The frame of the filter grating should face the exhaust side IMPORTANT The exhaust filter should be replaced in an area with a large free space 1 Release the two snap locks on the right and left for exhaust port door and remove the exhaust port door 2 Remove the exhaust f...

Page 56: ...blown by an overcurrent due to trouble with internal equipment The fuses are contained in the black box on the left of the power switch The replacing fuses should be those designated by CHIKO AIRTEC Designated fuses 218 Series from Littell fuse 250V 10A CBA 080 500 15A CBA 1200 2000 1 Open the cover of the fuse box The cover cannot be removed 2 Take out the fuse box using a flathead screwdriver or...

Page 57: ...ilter case 3 Remove the battery cover by extracting its two screws 4 Push the claw rightward and remove the button battery 5 Replace with a new button battery 6 Install the battery cover back in place 7 Cut off the electricity of the device 5 4 Daily Checkup Check item Frequency Check that Filter case Before operation Filter case is completely closed Suction port Before operation Suction port is n...

Page 58: ...ely Error No 2 Press the MODE SELECT button to move to the error history mode If there are two or more error warning occurrences the number of occurrences precedes the error number 3 If there are two or more error warning occurrences press the Up Down arrow buttons to check the error numbers 4 Take an action appropriate for the error number shown on the display 5 5 2 Error Warning Table page 56 5 ...

Page 59: ...perature around the blower is close to the error threshold Flashing Remains operational Follow the remedies for in 5 6 Troubleshooting Page 57 WARN2 Filter replacement time limit expired Operation continued at low air volume for more than preset period Flashing Remains operational Follow the remedies for in 5 6 Troubleshooting Page 57 WARN3 Inadequate pressure suction Suction pressure is low Flash...

Page 60: ...dary filter not in place Install the primary and secondary filters correctly Disengaged snap locks Engage the snap locks Lower suction force Clogged filter Replace filters 5 1 Replacing Filters page 51 If filters are left clogged the device may result in untrapped particles or temperature rise in dust collector Clogged piping or suction port Check if piping is clogged or the suction port blocked 2...

Page 61: ...log pressure signal Pins and In case of adding an inductor e g relay install a noise limiter approx 33 Ω 0 1 μF diode or the like Operation input signal Remote operation change signal Operating pressure signal Filter clogging signal Operation signal Abnormality signal GND DC 1 5V In case of adding an inductor e g relay install a noise limiter approx 33 Ω 0 1 μ F diode or the like LOAD LOAD DC 0 5V...

Page 62: ...1 to 5 V 0 2 V Device side Customer side Pin Pin Measuring instrument etc Reference circuit Monitor Device side Customer side Pin Pin State Point B C ON HIGH LOW OFF LOW HI Z Add a protection circuit so that the rating is not exceeded Current flows through the load when pin is LOW 24 V Max rating 50 V Load 100 mA Recommended DC voltage current 1 2 of maximum rating Reference circuit Device side Cu...

Page 63: ...al 3 Outputs a clogging signal Open collector output NPN Green Operation output signal 3 Outputs an operation signal ON lamp Open collector output NPN Green white Abnormality signal detection 3 Anomalous signal Detection Open collector output NPN Filter clogging signal When WARN2 WARN4 or WARN5 occurred Abnormality signal When any ERR occurred 1 Contact input non voltage contact 2 Analog input 0 t...

Page 64: ... it is possible to retrieve the information like the ON OFF operation and filter clogging status 6 2 1 RS485 Communication See 4 2 Communication Format Setting Mode When Equipped with Communication Function for instructions on configuring communication settings 4 2 Communication Format Setting Mode When Equipped with Communication Function page 47 6 2 2 Ethernet For details refer to the instructio...

Page 65: ...230 V single phase 9 5A 12 50 kPa CBA 2000AT3 HI V1 1200 W 200 V single phase 9 5 A 50 60 Hz 6 0 m3 min 9 60 kPa 67 to 70 dB 31 0 kg CBA 2000AT3 HI V1 CE 200 to 230 V single phase 9 5 A 1 Noise value is measured with a hose connected to the suction port at a distance of 1 m from the device on the A scale dB 2 Can be used in the area of 100 115V 7 2 Consumables List Part name Replacement intervals ...

Page 66: ...trical Diagram 7 3 1 CBA 080AT3 7 3 2 CBA 500AT3 これらの基板は説明 のため反体面を透視 した状態で記載して For illustration purpose these boards are viewed with the opposite sides seen through For illustration purpose these boards are viewed with the opposite sides seen through ...

Page 67: ...ndix 64 7 3 3 CBA 1200AT3 7 3 4 CBA 2000AT3 For illustration purpose these boards are viewed with the opposite sides seen through For illustration purpose these boards are viewed with the opposite sides seen through ...

Page 68: ...IRTEC designated sales agent Blemish contamination or other appearance change that may occur during use Replacement of any consumable or accessory or use of any part not designated by CHIKO AIRTEC Failure of damage due to falling after purchase or accident during transport Failure or damage due to natural disasters such as fire salt damage gaseous damage earthquake wind and flood damage lightning ...

Page 69: ...MEMO ...

Page 70: ...チコーエアーテック株式会社 CHIKO AIRTEC CO LTD 562 0012 大阪府箕面市白島 2 27 24 2 27 24 Hakushima Minoh Osaka 562 0012 Japan TEL 81 072 720 5151 FAX 81 072 720 5133 URL http chiko airtec jp ...

Reviews: