Chapter 5
Maintenance
and Checkup
58
5.6
Troubleshooting
No.
Trouble phenomenon
Cause
Remedy
①
Organic EL display
shows nothing.
Power not turned on
Turn on the power
Blown fuse
Replace the fuses.
Replacing Fuse” (page 54)
②
Motor fails to start or
suddenly stops
running.
Faulty motor
Call for repair.
The motor must be replaced.
Stopped due to
overload or abnormal
temperature
[1] Check that the exhaust/suction ports are
not blocked.
[2] Check the rated voltage.
[3] Check for multiple (octopus) connections.
[4] Check for motor overheat due to either
filter clogging or suction temperature.
After the checks [1] to [4], take corrective
action, and then turn the main power switch
off and back on.
If the operation cannot resume, the
temperature thermostat of the motor may be
active. Turn off the main power, and after 30
minutes, resume the operation.
Primary or secondary
filter not in place
Install the primary and secondary filters
correctly.
Disengaged snap
locks
Engage the snap locks.
③
Lower suction force
Clogged filter
Replace filters.
Replacing Filters” (page 52)
If filters are left clogged, the device may result
in “untrapped particles” or “temperature rise in
dust collector”.
Clogged piping or
suction port
Check if piping is clogged or the suction port
blocked.
Faulty motor
Call for repair.
The motor must be replaced.
④
Untrapped particles
Improper filter
installation
Reinstall filters.
Replacing Filters” (page 52)
Filter broken or past
service life
Replace filters.
Replacing Filters” (page 52)
Clogged filter
Replace filters.
⑤
Odd noise or
vibration from motor
Foreign matter
entered in blower
Call for repair.
Broken motor bearing
Call for repair.
Note: For other phenomena, contact CHIKO AIRTEC.