Chapter
4Configuring Settings
【
MODE SELECT mode
】
52
8.
Press the Up/Down arrow buttons to change the value.
9.
Press the ENTER button to determine the value.
Set the value in this order: hours, minutes, and seconds.
10.
To exit this mode, press the MODE SELECT button to return to normal mode.
4.5.2
Accumulated Run Time Reset Mode
This mode resets the accumulated run time (“Runtime”).
1.
Move to the MODE SELECT mode.
2.
Press the Up/Down arrow buttons to move to the other setting mode (“Other Setting”).
3.
Press the ENTER button.
The screen displays “Time Adjust”.
4.
Press the Up/Down arrow buttons to change the display to “[Runtime Reset]”.
5.
Press the ENTER button.
The display shows “Reset Runtime Y”, prompting confirmation to reset the accumulated run time.
To reset, press the ENTER button.
6.
To exit this mode, press the MODE SELECT button to return to normal mode.
4.5.3
Setpoint Reset Mode
This mode allows for restoring the defaults for communication format, air volume-down alert timing, and
resetting the accumulated run time.
7.
Move to the MODE SELECT mode.
8.
Press the Up/Down arrow buttons to move to the other setting mode (“Other Setting”).
9.
Press the ENTER button.
The screen displays “Time Adjust”.
10.
Press the Up/Down arrow buttons to change the display to “[Setting Reset]”.
11.
Press the ENTER button.
The display shows “1:YES”, prompting confirmation to reset setpoints.
To reset, press the ENTER button.
12.
The display shows “1:START” for reconfirmation.
13.
Press the ENTER button to reset the setpoints and move the device to normal mode.
Error History Mode
The error history allows for checking four occurrences of errors.
The error history is cleared by turning off the power switch.
1.
Move to the MODE SELECT mode.
2.
Press the Up/Down arrow buttons to move to the error history mode.
3.
Press the ENTER button.
The display indicates the number of the most recent error that has occurred and the accumulated
run time at that occurrence.
4.
Press the Down arrow button to display the history of four errors in order from the latest.
5.
To exit this mode, press the MODE SELECT button to return to normal mode.
Summary of Contents for CBA-1500AT3-HC-DSA-V1
Page 6: ...1 4 1 4 2 OFF 1 5...
Page 7: ...1 CMN023 005 Translation of the original instructions 5 1 6...
Page 8: ...2 6 2 2 1 200V 220 230V CE 1 1 2 1 1 HEPA 1 3m 200V 1 220 230V CE 1 1...
Page 12: ...2 10 2 4 3 OP kPa SP kPa DP kPa EP kPa Blower Runtime h 18 Total h Moter...
Page 13: ...3 CMN023 005 Translation of the original instructions 11 3 3 1 3 1 1 0 40 80 RH REMOVE 1 1 1...
Page 14: ...3 12 1 2 2 3 4 OFF ON 1 A OFF 40 50 A 2...
Page 22: ...5 20 5 5 1 WARN2 1 5 1 1 1 1 1 2 2 1 3 1 4 2 1...
Page 24: ...5 22 3 ACC 4 5 6 5 2 1 Littell fuse 218 250V 15A 1 2 3 ACC...
Page 28: ...5 26 5 7 EL ON ON 5 2 22 1 2 3 4 1 4 ON OFF 30 1 2 1 2 5 1 20 5 1 20 5 1 20 5 1 20...
Page 29: ...6 CMN023 005 Translation of the original instructions 27 6 6 1 6 1 1...
Page 30: ...6 28 1 5V 0 2V LOW DC 1 2...
Page 34: ...7 32 7 3 7 3 1 CBA 1500AT3 HC DSA V1...
Page 35: ...CMN023 005 Translation of the original instructions 33 12 7 2 7 2 31...
Page 36: ...34...
Page 69: ...MEMO...