6.6 

ヒューズについて 

Fuse

内部機器のトラブルによる過電流で、ヒューズが切れた時には、ヒューズを交換して下さい。

When the fuse is blown by excessive current generated by a trouble in the 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 
 
 

 
 

 
 

6.7 

日常点検

  Daily inspection

 

 
 
 
 

 

点検項目

 

Inspection item

 

フィルタケース

 

Filter case 

運転前

Before operation

排気の状態

 

Exhaust status 

Once/day

本体の振動

 

Vibrations of main body 

Once/day

フィルタの取り付け状態

 

Filter installation status 

Once/month

フィルタ目づまり状態

 

(吸引力確認)

 

Filter clogged status 
(Suction force check) 

運転時

During operation

ヒューズは、電源スイッチの右側の黒

The fuse is accommodated inside the black box provided on 
the right side of the MAIN POWER switch.

引き

Not pull it out.

 

Copyright  CHIKO  AIRTEC  CO.,

 

  15

 

 

Fuse

 

内部機器のトラブルによる過電流で、ヒューズが切れた時には、ヒューズを交換して下さい。

 

When the fuse is blown by excessive current generated by a trouble in the internal equipment, replace it.

Daily inspection 

 

頻度

 

Frequency

 

点検内容

Description

運転前

 

Before operation 

完全に閉じているか

 

Is the case closed completely

1回/日

 

Once/day 

排気口が閉ざされていないか

 

Is the exhaust port unclogged?

1回/日

 

Once/day 

異常振動、異常音がないか

 

設置レベルは出ているか

 

Are no abnormal vibrations 
generated? 
Is the installation level correct?

1回/月

 

Once/month 

フィルタ取り付けが緩んでいないか

Are the filters installed securely

運転時

 

During operation 

吸込みホース端の吸引力は適切
目詰まりランプが点灯していないか

  Does  the  suction  hose  end  offer  proper 
suction force? 
Is the clogging indicator lamp extinguished

黒いボックスの中にあります。 

The fuse is accommodated inside the black box provided on 
the right side of the MAIN POWER switch. 

き出せません 

Not pull it out. 

先の細いもので突き
出して下さい 

Push the fuse   
with a thin rod, 
and replace the fuse

 

[10A] 

チコーエアーテック株式会社 

Copyright  CHIKO  AIRTEC  CO.,  LTD.  2009

 

 

 
 

 

internal equipment, replace it.

 

点検内容

 

Description

 

the case closed completely? 

 

unclogged? 

 

abnormal vibrations or sounds 

correct? 

んでいないか

 

installed securely? 

適切か

 

していないか

 

the  suction  hose  end  offer  proper 

the clogging indicator lamp extinguished? 

Summary of Contents for CKU-400AT-HC-V1

Page 1: ...ng saving type clean box that realizes air technology in a compact body ual thoroughly and handle this CKU Series machine correctly so that you can use safely for a long time and enjoy its full perfor...

Page 2: ...losive dust the following substances Flammable substances Gasoline thinner benzene kerosene Aluminum magnesium titanium zinc epoxy etc Dust containing sparks Dust containing sparks generated by high c...

Page 3: ...ctor 8 4 4 Confirmation before operation SK 250AT 450AT 8 4 5 Operation procedure 9 5 Remote Cable Sold Separately 10 5 1 Electrical circuit diagram 10 5 2 Remote Cable 10 5 3 Color and signal of each...

Page 4: ...room temperature ambient temperature 0 to 40 C humidity 80 or less High temperature and dew condensation may cause electrical parts to fail and may cause an electrical shock 100 Provide sufficient spa...

Page 5: ...when the product recover peration without filter or with a clogged and damaged filter may cause trouble because foreign substances enter the blower Install the filter properly before operating the mac...

Page 6: ...ag Exhaust filter Copyright CHIKO AIRTEC CO 5 Name and Structure of Product Name of main body Standard accessories Collecting Adsorbing fine dust and fumes Protecting the circuit and the electrical pa...

Page 7: ...upply The power supply is single phase supply voltage range is 10 The power cable of 3 m with a grounding plug is included AT panel Operating the product with a different power supply may cause burst...

Page 8: ...eases by 1 level Minimum suction level Approximately 60 Hi 1 1 100 Hi switch Every time this switch is pressed the performance increases by 1 level Maximum suction level 100 ON switch and OFF switch t...

Page 9: ...grounding plug are connected correctly insulation is provided properly and the rated voltage is realized Confirm items 1 to 3 above and then proceed to the item 4 AT Turn ON the MAIN POWER switch and...

Page 10: ...ration procedure Connect the power plug to the electrical outlet suction hose hood to a proper position Turn ON the MAIN POWER switch and confirm that the power indicator Press the ON switch to start...

Page 11: ...n the ON and the panel is impossible to Temperature correction is not provided 3 5 6 F Attach a noise limiter Approximately 33 F to the output terminals Nos 1 2 and 3 When adding 33 0 1 1 2 3 5 6 8 7...

Page 12: ...The AT panel is disabled while the wires 4 and 8 are short circuited Yellow white Black White Operation pressure signal Output signals Transfers the current operation output Analog signal 0 5V Impedan...

Page 13: ...in body Transfer required output signals in accordance with the explanation in 5 3 Color and signal of each wire AT ON Lo Hi Change with Lo Hi switch pushing the ON switch of main body AT panel when y...

Page 14: ...the primary filter ter bag replace the secondary filter Make sure to turn OFF the main power and disconnect the power plug from the electrical outlet to cut off the electricity before starting Using a...

Page 15: ...he filter case The filter paper packing of the primary filter is inserted into the cylindrical pipe of the filter case Lightly push down the filter paper packing to remove it snap locks on the left an...

Page 16: ...tion Frequency Description Before operation Is the case closed completely Once day Is the exhaust port unclogged Once day Are no abnormal vibrations generated Is the installation level correct Once mo...

Page 17: ...hat the motor is not overheated by clogged filters 3 30 After checking 1 to 3 above remove the cause of error and press the RESET switch Or turn OFF and ON the MAIN POWER switch to reset the error sta...

Page 18: ...450 100V Single phase 8 2 50 60 7 2 85 73 40 1 dB Note The Noise column indicates a value dB on the scale A at 1 m on the main body side when the hose is connected to the suction port 10 Consumable P...

Page 19: ...ect to change without prior notice Memo about purchase Model Manufacturer s serial number Date of purchase Start of operation Your name Address Phone Person in charge LTD 562 0012 1 1 33 1 1 33 Hakush...

Reviews: