フィルタについて(フィルタ交換時期について参照)目詰まり状況をお知らせします。

 

(ホース圧迫や、ホース先端を絞込んだりした場合には、ランプが点灯し続ける場合があります)

 

Filter indicator lamps (Refer to “ Filter replacement timing”.) These lamps indicate the filter clogging status. 
(A lamp may keep ON when the hose is pressed or when the hose end is compressed.) 

 

正常(緑

LED

点灯):正常に運転しています

 

Normal lamp (green LED):Remains ON while the dust collector is operating normally. 

 

確認(黄

LED

点灯):能力が低下していることをお知らせします。フィルタ・ダクトホース等を確認して下さい。

 

Cleaning lump(yellow LED)

Suction power is lowering. Check filter and duct hose. 

 

交換(赤

LED

点灯):フィルタを交換してください。

 

Replacement lamp (red LED): Turns ON when replacement of the filter is necessary. Replace the filter. 
 
 
 
 
 
 
 
 

 

異常お知らせについて

  Error indicator lamps 

 

過負荷(赤

LED

点灯):モータ異常が発生した時に赤

LED

ランプ点灯し、運転を停止します。

 

Overload  lamp  (red  LED):  Turns  ON  when  an  error  occurs  in  the  motor.  The  dust  collector  stops 
operation. 

 

異常温度(赤

PL

点灯):モータが異常温度になった時に点灯、停止します。

 

Abnormal temperature lamp (red PL): Turns ON when the motor temperature becomes abnormal. 
The dust collector stops operation. 

 

原因除去後、リセットスイッチで復帰させ(ランプ消灯)、運転操作を開始してください。

 

After removing the cause of error, press the RESET switch.    When the lamp turns OFF, restart 
the operation. 

 

主電源を切ることでも、ランプが消灯し、運転再開が可能です。

 

Or turn OFF the main power to turn OFF the lamp, and then restart the operation. 

 

能力レベルについて

  Performance level indicator 

7

段階の

LED

により集塵機の吸込みを調整します。

 

Seven LED lamps indicate the suction level of the dust collector. 

 

Lo

1

回押すごとに1レベル降下(最小約

60

%)

 

Lo switch: Every time this switch is pressed, the performance decreases by 1 level.    (Minimum suction 
level: Approximately 60%) 

 

Hi

1

回押すごとに

1

レベル上昇(最大

100

%)

 

Hi switch: Every time this switch is pressed, the performance increases by 1 level.    (Maximum suction 
level: 100%) 

 

ON

/

OFF(タクトスイッチ)と主電源について

 

ON switch and OFF switch (tactile switches) and MAIN POWER indicator lamp 

 

本体側面の主電源を入れると、ランプが点灯します。

 

MAIN POWER lamp: Turns ON when the MAIN POWER switch provided on the side of the main body is 
turned ON. 

 

ON

(緑

LED

点灯):起動  能力レベル設定可能

 

ON switch (with green LED): Starts up the dust collector, and enables setting of the performance level. 

 

OFF

:運転停止

 

OFF switch: Stops operation of the dust collector. 

(能力レベルは、OFF ボタンで記憶されますので、再スタートした時にはそのレベルで運転を開始します。 
但し、運転中に能力レベルを変更し、停電などで主電源により電源 OFF した場合には、変更前のレベルで運転が開
始されます。) 

(As the suction level is memorized by the OFF button, the operation starts in the same level at the time of 
restart. However if the main power switch shut down by the blackout when suctionlevel is changed during 
the operation, machine starts in suction level before the change.) 

 

リセットスイッチ

  RESET switch 

②の原因除去後、復帰する場合に使用します。先端の丸い棒などで、2秒間押して下さい。

 

Press and hold this switch with a thin rod having a round tip for 2 seconds to restore the dust collector after 
removing the cause of error indicated by a lamp [2]. 

 
 
 
 
 
 
 
 

 

 

気圧の変化や温度条件により停止状態の圧力表示は-0.2kPa〜0.2kPa の範囲で変化します。また、外部ノイズの影響によ
り一時的に圧力数値が変化する場合があります。 

The pressure representation when operation stops changes within the range from -0.2 to 0.2.   
Because there is a change in the atmospheric pressure and the temperature.

 

And the pressure representation might temporarily change because it is influenced by the extrinsic noise

※圧力数値

/ The pressure representation

フィルタランプ表示

/ Filter indicator lamps 

Summary of Contents for CKU-400AT-HC-V1

Page 1: ...ng saving type clean box that realizes air technology in a compact body ual thoroughly and handle this CKU Series machine correctly so that you can use safely for a long time and enjoy its full perfor...

Page 2: ...losive dust the following substances Flammable substances Gasoline thinner benzene kerosene Aluminum magnesium titanium zinc epoxy etc Dust containing sparks Dust containing sparks generated by high c...

Page 3: ...ctor 8 4 4 Confirmation before operation SK 250AT 450AT 8 4 5 Operation procedure 9 5 Remote Cable Sold Separately 10 5 1 Electrical circuit diagram 10 5 2 Remote Cable 10 5 3 Color and signal of each...

Page 4: ...room temperature ambient temperature 0 to 40 C humidity 80 or less High temperature and dew condensation may cause electrical parts to fail and may cause an electrical shock 100 Provide sufficient spa...

Page 5: ...when the product recover peration without filter or with a clogged and damaged filter may cause trouble because foreign substances enter the blower Install the filter properly before operating the mac...

Page 6: ...ag Exhaust filter Copyright CHIKO AIRTEC CO 5 Name and Structure of Product Name of main body Standard accessories Collecting Adsorbing fine dust and fumes Protecting the circuit and the electrical pa...

Page 7: ...upply The power supply is single phase supply voltage range is 10 The power cable of 3 m with a grounding plug is included AT panel Operating the product with a different power supply may cause burst...

Page 8: ...eases by 1 level Minimum suction level Approximately 60 Hi 1 1 100 Hi switch Every time this switch is pressed the performance increases by 1 level Maximum suction level 100 ON switch and OFF switch t...

Page 9: ...grounding plug are connected correctly insulation is provided properly and the rated voltage is realized Confirm items 1 to 3 above and then proceed to the item 4 AT Turn ON the MAIN POWER switch and...

Page 10: ...ration procedure Connect the power plug to the electrical outlet suction hose hood to a proper position Turn ON the MAIN POWER switch and confirm that the power indicator Press the ON switch to start...

Page 11: ...n the ON and the panel is impossible to Temperature correction is not provided 3 5 6 F Attach a noise limiter Approximately 33 F to the output terminals Nos 1 2 and 3 When adding 33 0 1 1 2 3 5 6 8 7...

Page 12: ...The AT panel is disabled while the wires 4 and 8 are short circuited Yellow white Black White Operation pressure signal Output signals Transfers the current operation output Analog signal 0 5V Impedan...

Page 13: ...in body Transfer required output signals in accordance with the explanation in 5 3 Color and signal of each wire AT ON Lo Hi Change with Lo Hi switch pushing the ON switch of main body AT panel when y...

Page 14: ...the primary filter ter bag replace the secondary filter Make sure to turn OFF the main power and disconnect the power plug from the electrical outlet to cut off the electricity before starting Using a...

Page 15: ...he filter case The filter paper packing of the primary filter is inserted into the cylindrical pipe of the filter case Lightly push down the filter paper packing to remove it snap locks on the left an...

Page 16: ...tion Frequency Description Before operation Is the case closed completely Once day Is the exhaust port unclogged Once day Are no abnormal vibrations generated Is the installation level correct Once mo...

Page 17: ...hat the motor is not overheated by clogged filters 3 30 After checking 1 to 3 above remove the cause of error and press the RESET switch Or turn OFF and ON the MAIN POWER switch to reset the error sta...

Page 18: ...450 100V Single phase 8 2 50 60 7 2 85 73 40 1 dB Note The Noise column indicates a value dB on the scale A at 1 m on the main body side when the hose is connected to the suction port 10 Consumable P...

Page 19: ...ect to change without prior notice Memo about purchase Model Manufacturer s serial number Date of purchase Start of operation Your name Address Phone Person in charge LTD 562 0012 1 1 33 1 1 33 Hakush...

Reviews: