Product description:

The product is an electrical smoke detector that is operated with 9V and an additional 3x1.5V (AA Mignon). You can 

use this smoke detector with a 9V battery (type is 6LR61 or 6F22) for about 1 year, depending on the type. The high 

sensitivity of the smoke detector also detects dense smoke from smoldering fires and black smoke. This means fire 

can be extinguished before it spreads. This smoke detector can be installed in any room except for bathrooms. During 

installation, it must be ensured that people can hear the alarm and thus react as quickly as possible. Install at least 

one smoke alarm in the hallway near the living area and bedroom. By installing it near the living and sleeping areas, 

you can ensure

Recommended installation concept for typical one-storey residential buildings:

Mount the smoke detector on ceilings or inside walls. Every corridor should be equipped with a smoke detector. If the 

corridor is longer than 10 meters, we recommend installing one smoke detector at each end of the corridor. If you live 

in the basement, a smoke detector should be mounted on the basement ceiling.

Recommended installation concept for typical multi-storey residential buildings:

Proceed exactly as in the assembly concept for one-story residential buildings. However, you should also install a 

smoke detector on each floor of the stairwell, but at least on the first and second floors.

Important safety information:

1. The test button is specially designed to test the alarm function of the smoke detector. Never test the smoke 

detector with other test equipment! To ensure the smoke alarm is working properly, test the smoke alarm every 

week.

2. For your safety: Never remove the battery to stop the alarm. You can open the window or turn on a fan to let the 

smoke out and then stop the alarm.

3. Consult an electrician to install the smoke alarm. When installing, the electrician must follow local and national 

requirements and building regulations.

4. This smoke detector is particularly suitable for a single-family household. In residential buildings with several 

families, individual smoke detectors are required for each family. Never install smoke detectors in empty residential 

buildings. Furthermore, smoke detectors must not be used as alarm backup systems.

5. A smoke detector should be installed in every room.

6. The smoke detector cannot trigger an alarm in the following situations:

a) the fire is too far from the living area,
b) the fire is on another floor,
c) the fire is in a gas duct,
d) the fire is in a wall,
e) the fire is on the roof,
f) in an airtight place.
ATTENTION: In the situations mentioned above, the smoke detector cannot trigger an alarm. The smoke detector 

cannot detect and warn of fires outside of the detection area or outside of the room.

7. The smoke alarm sounds to warn the residents of a fire. However, there are situations in which individual residents 

cannot hear the alarm. Examples: The resident(s).
a) are not in the room where a smoke detector is installed,
b) sleep deeply or snore very loudly,
c) are under the influence of medication, drugs or alcohol,

d) have impaired hearing or wear hearing protection,

If you find that the smoke alarm is not sounding, first check the smoke alarm. In any case, it must be ensured that 

everyone in the house can hear the alarm and
can react quickly to avoid personal injury. If individual residents have poor hearing, install a smoke detector with a 

display or vibration system.

Reproduction only with the permission of 

ChiliTec GmbH, Bäckerberg 12, 38165 Lehre

EAR (WEEE): DE25841852

LUCID PackagingG: DE5562476395648

GRS (UBA Register) No.: 21003466

Summary of Contents for CT-RMPro

Page 1: ...nd the packaging must be included Thank you We reserve the right to misprints or changes to the packaging the product or the instructions Notes on cleaning environmental protection and battery operati...

Page 2: ...ver remove the battery to stop the alarm You can open the window or turn on a fan to let the smoke out and then stop the alarm 3 Consult an electrician to install the smoke alarm When installing the e...

Page 3: ...etector cannot be attached to the mounting plate without batteries The smoke detector should not be used in the following places 1 Near flammable electrical appliances or in areas such as B in the kit...

Page 4: ...an alarm goes off 2 There are 2 escape route symbols in each room 3 Plan suitable escape routes 4 Explain to your family members how to properly open a door heated by fire 5 In the event of a fire in...

Page 5: ...alarm is 10 years It must then be replaced in order to continue to guarantee your safety The best mounting location for your smoke detector First you need to mount a smoke detector in the bedroom or...

Page 6: ...press the TEST button on the main detector within 18 seconds The main detector acknowledges with an alarm and the secondary detectors should now also trigger an alarm The alarm goes off again after a...

Page 7: ...hre Essenrode Germany EAN 4250416313249 item no 21198 designation wireless smoke alarm device CT RM Pro type LM 101LB Product designation time or date of first placing on the market Wireless smoke ala...

Page 8: ...declaration of performance concerning a construction product for which a European technical assessment has been issued Not applicable 9 Declared performance Essential Properties power Harmonized techn...

Reviews: