8. The smoke alarm can only sound when it detects the presence of smoke or burning granules; the smoke detector
can sense the changed temperature, flame or flammable gases. This device was developed for small fires. However,
there are fires that start suddenly, or are explosive, or are caused by insufficient safety measures. In such situations,
the smoke detector cannot warn the residents of the house quickly enough about the fire.
9. The functionality of the smoke detector can also reach its limits. The smoke alarm should not be considered the
only protection against fire. If the smoke alarm is installed, it does not mean that you are absolutely safe. The landlord
and residents are responsible for their own lives and property. In addition, there are also situations in which the
smoke detector could not be functional. That's why you need to check the smoke detector every week.
Battery specification:
Target voltage: DC 9V (alkaline battery or zinc-carbon battery) Type: 6F22 (zinc-carbon battery) or 6LR61 (alkaline
battery), 3x1.5V alkaline mignon (AA)! No rechargeable batteries may be used!
Replacing the batteries :
1. Turn the smoke detector counterclockwise, then take out the alarm part.
2. Remove the battery and insert a new battery (spill-proof!).
3. Place the new battery in the battery holder. Put on the alarm part, turn it clockwise.
4. Use the test button to test the smoke detector. To do this, press and hold the test button for approx. 5 seconds.
Release the button as soon as the alarm sounds, this "test" alarm will stop by itself after a few seconds. When
inserting the last AA battery, please push down the red tab first, then push the battery in. The smoke detector cannot
be attached to the mounting plate without batteries.
The smoke detector should not be used in the following places!
1. Near flammable electrical appliances or in areas such as B. in the kitchen, near furniture or water heaters. If
necessary, install a suitable smoke detector in such areas.
2. In areas with high temperatures eg near dishwashers or washing machines - the smoke detector must be
installed at a distance of at least 3 meters from these devices.
3. The smoke detector must be installed at a distance of at least 1 meter from the air conditioning systems or
ventilation. Smoke spreads quickly in close proximity to these devices and the smoke detector cannot detect the
smoke in these environmental conditions.
4. In rooms with a temperature below 4 degrees Celsius or above 37 degrees Celsius.
5. Dusty or unclean areas. Areas with a large number of insects.
6. Not in the kitchen, not in bathrooms and not in other wet rooms!
Checking the smoke detector:
1. Check that each smoke alarm is properly installed and adjusted.
2. Never test the smoke detector with fire. The smoke detector and also the room could burn down.
3. Check the working condition of the smoke detector every week and after every holiday.
4. When checking the smoke alarm, keep your arms' distance from the device. Check the smoke detector once a week
according to the following steps.
5. Use the test button to test the smoke detector. To do this, press and hold the test button for approx. 5 seconds.
Release the button as soon as the alarm sounds, this "test" alarm will stop by itself after a few seconds. When
inserting the last AA battery, please push down the red tab first, then push the battery in. The smoke detector
cannot be attached to the mounting plate without batteries.