Programming of the main and the secondary alarms

Tip: It doesn't matter which detector is the main detector or secondary detector, if all detectors have been correctly 

trained, the alarm will sound on all detectors, regardless of which detector detects the smoke development first! The 

permanent wireless connection of all smoke detectors can be released and, if necessary, renewed by removing the 3 

mignon batteries (for approx. 5 minutes) (see 1-4). Turn the smoke alarm counter-clockwise. Remove the mounting 

plate. Hold the mounting plate at the position where you will mount the smoke alarm. Test all detectors to be 

installed by pressing (3-5 sec) the test button. The alarm will turn off after a few seconds. The radio connection system 

is based on the main and secondary detector principle. It is best to place all detectors to be installed/connected next 

to each other.
1. Insert fresh/new batteries, pay attention to the correct polarity!
2. Take the first detector (it will become main) and press the LEARN button twice in a row, then the green LED 

should light up! (remains approx. 18 seconds, as long as the detectors can be connected together.)

3. Take one or more additional detectors (these become secondary) and press the LEARN button on this (..or all) 

once, the red LED should light up.

4. Now press the TEST button on the main detector within 18 seconds. The main detector acknowledges with an alarm and 

the secondary detectors should now also trigger an alarm. The alarm goes off again after a short time. Now check again by 

pressing a test button whether all smoke detectors (..with a 1-2 second time delay) trigger an alarm.

Installation on wall or ceiling:

Turn the smoke alarm counter-clockwise. Remove the mounting plate.
• Hold the mounting plate at the position where you want to mount the smoke detector. Mark the holes with a pencil. 

These positions are necessary for the mounting holes.
• Drill 2 holes according to the markings. The diameter of the holes must be 5mm. Insert a plastic anchor into each of 

the 2 holes.
• Place the mounting plate on the plastic dowels. Fasten the mounting plate to the dowels with the screws (see figure 

5). • Insert the battery into the battery compartment.
• Place the smoke detector on the mounting plate. Rotate the smoke alarm clockwise until the smoke alarm clicks into 

place. (Note: Mounting plate can only be mounted with battery installed).

• Test the smoke detector with the test button. To avoid accidents, properly mount the smoke detector on the wall or 

ceiling according to the mounting requirements.

Tip:

The smoke detector cannot be placed on the mounting 

plate without batteries:
This safety precaution protects you from forgetting the 

batteries!

Reproduction only with the permission of 

ChiliTec GmbH, Bäckerberg 12, 38165 Lehre

EAR (WEEE): DE25841852

LUCID PackagingG: DE5562476395648

GRS (UBA Register) No.: 21003466

Summary of Contents for CT-RMPro

Page 1: ...nd the packaging must be included Thank you We reserve the right to misprints or changes to the packaging the product or the instructions Notes on cleaning environmental protection and battery operati...

Page 2: ...ver remove the battery to stop the alarm You can open the window or turn on a fan to let the smoke out and then stop the alarm 3 Consult an electrician to install the smoke alarm When installing the e...

Page 3: ...etector cannot be attached to the mounting plate without batteries The smoke detector should not be used in the following places 1 Near flammable electrical appliances or in areas such as B in the kit...

Page 4: ...an alarm goes off 2 There are 2 escape route symbols in each room 3 Plan suitable escape routes 4 Explain to your family members how to properly open a door heated by fire 5 In the event of a fire in...

Page 5: ...alarm is 10 years It must then be replaced in order to continue to guarantee your safety The best mounting location for your smoke detector First you need to mount a smoke detector in the bedroom or...

Page 6: ...press the TEST button on the main detector within 18 seconds The main detector acknowledges with an alarm and the secondary detectors should now also trigger an alarm The alarm goes off again after a...

Page 7: ...hre Essenrode Germany EAN 4250416313249 item no 21198 designation wireless smoke alarm device CT RM Pro type LM 101LB Product designation time or date of first placing on the market Wireless smoke ala...

Page 8: ...declaration of performance concerning a construction product for which a European technical assessment has been issued Not applicable 9 Declared performance Essential Properties power Harmonized techn...

Reviews: