background image

Status: 12/2021 - Version 1.00

Page 2

Item No. 23215

Safety instructions (only for 230V ~ / 50Hz components)

The installation or the intervention in the power grid can lead to very serious injuries up to a fatal electric shock. The 

absence of voltage must be checked! • It is essential to observe the UVV (accident prevention regulations) and VDE 

regulations! Operation only permitted on 230V ~ / 50Hz • Installation may only be carried out with approved and 

tested tools • No assembly on or in the vicinity (50cm distance) of combustible / inflammable materials (ignition 

temperature <200 ° C). Also watch out for gas

- / dust / room air mixture. If necessary, ventilate the room thoroughly beforehand. • Before doing any work, switch 

off the circuit in which the installation is being carried out completely at the main fuse! Otherwise there is a RISK OF 

LIFE !! • To connect all 230V ~ / 50Hz components, the minimum cross-section (1.5mm²) of the connection line must 

never be undershot. It is imperative that you use a cable that has been expressly approved for this purpose. • There 

are no parts to be maintained inside this product. • The correct connection must be checked;

• Operation is only allowed individually, installing in succession is prohibited!

First setup (connection) of the respective components

The two components must be “married” to each other once before being used for the first time. The connection then 

remains permanent. To do this, follow the instructions on page 3. “Teaching in the transmitter”. The process only 

takes a few seconds. Insert the batteries, with correct polarity, into the transmitter and switch it on (page 3, Fig. 3a). 

Two or more receivers to be connected (e.g. socket) must have a minimum distance of 90cm from one another. The 

radio connections are coded with a 24-bit key, which means that it is not possible to unintentionally teach in third-

party devices (e.g. with neighbors). Disturbance of the radio signal is also less likely. See also note on page 1, 

compatibility with other manufacturers.

Connection of the socket version 23213

Plug the socket into a protective contact socket. After approx. 3 seconds the indicator LED (Fig. 1- shown in red) starts 

to flash (or automatically when plugged in in the factory state!). The flashing signals the registration mode. If the LED 

does NOT flash (approx. Every second) - Press and hold the ON / OFF switch of the receiver (Fig. 1 - red or green) for 

approx. 3 seconds.

Functional level

Preselection mode

Actual temperature

Program 1-8

Target temperature

Actual humidity

Actual day of the week

Actual time

Fig. 1

Start / end time

Fig. 1a

Two or more sockets to be installed must be at least 90 cm apart. The radio connections are coded with a 24-bit key, 

which means that it is not possible to unintentionally teach in third-party devices (e.g. with neighbors). Interference 

with the radio signal is also unlikely because the radio connection between the components is secure.

Reproduction only with permission from 

ChiliTec GmbH, Bäckerberg 12, 38165 Lehr

EAR (WEEE): DE25841852

LUCID Packaging Act: DE5562476395648

GRS (UBA register) no .: 21003466