INSTALLATION

(Shown with optional Installation Kit)

No set in/out. Either configuration is acceptable.

Place chiller in ventilated location, ensuring adequate space (four to six inches) for air flow.

DO NOT PLACE CHILLER IN CABINET OR OTHER ENCLOSURE.

read entire manual 
before installing 
chiller

Place chiller in desired location ensuring 

adequate space for air movement.

Determine pump location and cut 

a piece of tubing to appropriate length.

Attach clear PVC u-bend barb fitting to 

end of cut tubing. Attach other end of 

tubing to pump. Secure with hose clamps.

Cut second length of tubing to connect 

the other end of barb fitting to the chiller. 

Secure both ends with a hose clamp.

Cut another piece of tubing to connect 

chiller and second U-bend. Secure with 

hose clamp.

U-bends should now be connected as 

shown.

Tubing should now be connected to 

chiller as shown.

Installation complete.

1

2

3

4

5

6

7

8

3

Summary of Contents for CSXC-1

Page 1: ...ERMOELECTRIC CHILLER OWNER S MANUAL SPECIFICATIONS Chill SolutionsThermoelectric Chiller Power Supply 90 240VAC 50 60 Hz worldwide CeramicThermoelectric Element CFC Refrigerant Free www chillsolutions com ...

Page 2: ...hen dissipated by the fan This technology allows for very precise and stable temperature control that is not available with standard compressor and refrigerant based chillers After installing and powering up the unit allow 24 hours for the water temperature to stabilize before assessing performance TABLE OF CONTENTS IMPORTANT SAFETY PRECAUTIONS 2 INSTALLATION 3 GETTING STARTED 4 MAINTENANCE 5 WARR...

Page 3: ...ng the power cord and coming into contact with appliance plug If the power plug becomes wet DO NOT unplug the cord Disconnect the fuse or circuit breaker that supplies power to the plug first Then proceed to unplug the chiller power cord and check for the presence of water in the AC power receptacle 8 If an extension cord is necessary an extension cord with the proper amperage rating should be inco...

Page 4: ...e for air movement Determine pump location and cut a piece of tubing to appropriate length Attach clear PVC u bend barb fitting to end of cut tubing Attach other end of tubing to pump Secure with hose clamps Cut second length of tubing to connect the other end of barb fitting to the chiller Secure both ends with a hose clamp Cut another piece of tubing to connect chiller and second U bend Secure wit...

Page 5: ...lue and the fan turn on which indicates the unit is cooling 6 Once the set temperature is reached the unit will turn on and off as necessary to maintain the desired temperature set point It is normal for the LED to change from blue to green and back to blue Error Display If the unit s digital readout displays a code as listed below the unit is not functioning as designed The following list of codes...

Page 6: ...erformed every 3 months to maintain maximum efficiency Heatsink Fan Cleaning Depending on environmental conditions the fan blades or heatsink may accumulate dust This should be removed by either compressed air or a vacuum taking care to not damage the heatsink fins or fan blades and allow free air movement though the unit It is important to keep the chiller assembly clean Care must be taken when remo...

Page 7: ...tions LLC will at its discretion replace or repair the defects at no charge to the customer excluding shipping and handling This warranty does not cover intentional or accidental damage to the unit as a result of user misuse Loss of livestock is not covered by this warranty Please contact us at support chillsolutions com in order to obtain a return authorization number and for further instructions...