Every Logical Link registered by the TK3721 has an associated SLA maintained by the TK3721, and stored internally in its NVS database 

(if enabled to do so). In the upstream direction, the TK3721 uses a reporting mechanism specified by 802.3ah to monitor the status of 

each  registered  link.  When  a  particular  Link’s  FIFO(s)  has  data  to  send  this  information  will  be  conveyed  to  the  OLT  in  the  form  of  a 

report message.  The OLT will use this information and the SLA associated  with the link to schedule a time  slot in which the link may 

transmit its data. Because the OLT schedules the links, rather than relying on mechanisms in the ONU, service contracts are enforced in 

the  central  office,  and  excess  bandwidth  may  be  allocated  efficiently.  SLA  enforcement  is  accurate  to  within  2%  of  the  provisioned 

value. 

7.8.1 Enable SLA

   

If checked, the OLT will allow the element to transmit user data.

   

7.8.2 Max Bw

     

Configures the maximum sustained rate at which a link may transmit data. 

7.8.3 Min Bw   

Configures the sustained rate at which the user may transmit without loss of data, this value should always be less than or equal to Max 

Bw. 

7.8.4 Mode

   

Determines the scheduler level 

From the perspective of the GUI or other external devise managing the TK3721 “Delete” semantically 

equivalent to restore factory default and “Create” is equivalent to change the SLA from default value.   

7.8.5 Enable SLA

   

This attribute allows the host to disable SLA’s 

 

It  is  important  to  note  that though  the  logical  link  panel appears  grouped  under  the  ONU,  logical  link  attributes  are  NOT  necessarily 

attributes  of  the  ONU  itself.  Logical  links  ALWAYS  make  two  associations  one  with  the  ONU  and  one  with  the  OLT.  Unless  explicitly 

specified, logical link parameters may be parameters of the OLT, ONU or both. It is best to assume that ALL operations performed on a 

logical link involve OAM transactions with the ONU. 

Though the TK3721 has a Min/Max FIFO scheduler in the upstream direction, the DBA is not directly influenced by the Min scheduler. 

Instead it responds to signals generated by queue depth. To ensure that the Min’s are scheduled accurately it is necessary to restrict 

the total upstream bandwidth of the PON by 50 to 100Mbps. This can be accomplished by provisioning an aggregate SLA. 

As  per  IEEE  802.3ah,  any  ONU  admitted  to  the  network  will  be  granted  a  small  amount  of  bandwidth  sufficient  for  minimal  OAM 

operation, even if the SLA is disabled. A disabled SLA can use up to 256K. As per specification the ONU is not aware of SLA’s, and thus 

will continue to transmit user data which will be dropped by the OLT. To prevent the ONU from transmitting this unwanted data it is 

recommended  that  the  ONU  be  configured  in  strict  boot  mode.  In  this  mode  the  ONU  will  ONLY  transmit  user  data  after  the  host 

software has explicitly enabled it to do so. 

In strict (or host driven) boot mode the SLA will be configured in the disabled state every time the link is registered. In auto-boot mode 

the state of the SLA is enabled by default and stored in the OLT NVS if NVS is enabled. 

8 Port Management 

Summary of Contents for SNA8110T

Page 1: ...SNA8110T Gepon OLT User Manual www stephen tele com SNA8110T GEPON SYSTEM OLT User Manual STEPHEN TECHNOLOGIES CO LIMITED ALL RIGHTS RESERVED...

Page 2: ...and a switch button as the following picture 3 Back panel instruction Back panel of ONU from left to right in turn is 16 kinds of status indicators a PON Port fiber port two RJ45 Ports a bunch port a...

Page 3: ...exibility high reliability managing free expansibility group web and QoS guarantee are its features SNA8110T integrates EPON system based on the IEEE802 3ah new standard the fiber speed of upstream an...

Page 4: ...ter 2 Installation and link 1 Attention item for setting Please insure that there is suitable work environment and enough free space before installing machine Please note the installing requirement as...

Page 5: ...r consists of the underlying messaging system used by the GUI This layer is responsible for parsing and queuing of Host Interface Messages as well as providing reliability The next layer is the applic...

Page 6: ...to the OLT Thus that depending on very minor timing differences between command response times the GUI event log trace will be different It is important to note that all host interface messages are r...

Page 7: ...low chart of the message exchange sequence is presented Where the message performs a complex operation on the PON a related diagram may be present as a visual aid Most panels are subdivided into boxes...

Page 8: ...alue ms When the timer expires the loopback will automatically be canceled 6 3 MPCP Parameters 6 3 1 Period The interval at which the OLT will issue a discovery gate 6 3 2 Window The discovery window...

Page 9: ...NU deployment 7 2 Aggregate Shaper This command lets the Host restrict the bandwidth available to the OLT for user data traffic in each direction This feature can be used to protect the core network f...

Page 10: ...plying this command otherwise the OLT FIFOs will become corrupt It is recommend that this operation be performed once during the initial bring up of the PON 7 4 Shaper Drop Down Weights This command i...

Page 11: ...mine if it has any data to transmit Smaller values result in lower latency and increased overhead For priority 0 the scheduling latency is approximately equal to the larger of the polling rate and the...

Page 12: ...the host to disable SLA s It is important to note that though the logical link panel appears grouped under the ONU logical link attributes are NOT necessarily attributes of the ONU itself Logical link...

Page 13: ...e flow control Note however that pause frames will be transmitted regardless of the capabilities reported by the link partner 8 1 1 Configuring Port in Loop Allows the user to set a loop back currentl...

Page 14: ...mode However multiple links each provisioned in a different mode may be associated with a given egress ONU port 9 1 1 Changing the bridging mode for a particular logical link Notice that after the bri...

Page 15: ...rovisioning box a second box appears to the right that is used to display a list of all logical links in the provisioned VLAN No links will be displayed in this box until the VLAN provisioning is appl...

Page 16: ...user to select the VID The VID will be inserted into upstream frames arriving on links provisioned in the VLAN Downstream the VID will be used for classification 9 1 6 2 Upstream CoS The upstream CoS...

Page 17: ...tructing an OLT Filtering Rule Step 1 Choose the Field Select Field Selects defined by the OLT are given a descriptive label Step 2 Choose an appropriate Operator The operator tests the portion of the...

Page 18: ...nce levels 0 being the highest priority and 7 being the lowest Currently the precedence level of user provisioned filtering rules is of little importance Step 3 Add the filtering rule to the OLT by cl...

Page 19: ...relay agent RFC 3046 This will enable the OLT to insert the Relay Agent Sub Option into snooped frames 9 3 3 DHCP IPv4 Address Learning 9 3 3 DHCP IPv4 Enables IPv4 address learning via DHCP snooping...

Page 20: ...nclude A common management interface for ONU and OLT alarms Soak of alarms on a per alarm ID basis Auditing of all alarms known to the OLT Setting of alarm thresholds for ONU and OLT alarms Autonomous...

Page 21: ...was cleared in the column labeled Disposition The GUI has 3 different alarm dispositions autonomous audit and internal 10 2 Enabling alarm auditing The GUI can be configured to perform a periodic aud...

Page 22: ...alling thresholds and then click the apply button When the transaction completes successfully the Apply and Revert buttons will turn grey indicating that the OLT and GUI values are synchronized Note t...

Page 23: ...ion of user data traffic and filtering of user data traffic Because these operations are very complex the user interface is divided between several panels The ONU Queue configuration panel allows the...

Page 24: ...he full FIFO name is 1 2 indicating that the FIFO is 2 of User Port 1 11 1 2 Provisioning Number of Logical Links to Register Up to 3 Links may be registered per ONU 6 on a TK3711 The number of Logica...

Page 25: ...urpose of the Flooding FIFO is beyond the scope of this document 11 1 5 Provisioning Upstream FIFOs Step 1 Adding a FIFO to an ONU Logical Link is a similar procedure First click on either of the ONU...

Page 26: ...from the Quick Cfg drop down box or typing its name and clicking the Delete button Notice that the GUI prevents the user from adding more FIFOs than the ONU supports It will also prevent the user from...

Page 27: ...Engine Most ONU classification engines are configured on a per port basis However the TK3701 supports only upstream and downstream classification The Port field allows the operator to choose the set o...

Page 28: ...ssing the mouse button at the start of the field dragging it to the end of the field and then releasing the mouse button Notice that after the field has been selected the Name will change to reflect t...

Page 29: ...t Field Selects defined by the ONU are given a descriptive label User Defined field selects are labeled User 1 User 2 User N All field select labels begin with an index value The index value correlate...

Page 30: ...is classified A classification rule with higher precedence than a filtering rule can be used to override a filtering function Step 2 Select the FIFO for classification First select the ingress port th...

Page 31: ...ng Q The GUI Uses the convention Entity ID FIFO Number to denote a particular FIFO The Entity ID corresponds to link index upstream and the ONU User Port upstream If you forgot to add the Link Index c...

Page 32: ...In the previous section we learned that Classification Rules are used to allow certain classes of traffic into the ONU data path As you might imagine Filtering Rules serve the opposite purpose blocki...

Page 33: ...ering Rule Step 1 Select the Port to Filter Step 2 Set the rule precedence level The Rule Level may be configured for 1 of 8 different precedence levels 0 being the highest priority and 7 being the lo...

Page 34: ...s as an RFC 2236 non querier aggregating the reports sent by the several connected hosts and making the system appear to an attached video server or other device connected to the OLT s NNI as if there...

Page 35: ...ovisioned to a very large value Query Response Timeout units after the OLT issues the General Query the OLT will decrement the robustness variable for each group joined for which the OLT has not recei...

Page 36: ...e enabled only if the authentication succeeds Otherwise if checked SLAs will be enabled unconditionally This is useful for strict boot mode Enable OLT after boot If checked this attribute will cause t...

Page 37: ...ww stephen tele com Select the objective upgrade file as following Click open button then the ONUsoftware upgrade will finish 4 2 OLT software upgrade The process of OLT software upgrade is the same w...

Page 38: ...is document The information provided by this document is believed to be accurate and reliable to the publication date of this document However Stephen Technologies Co LTD assumes no responsibility for...

Reviews: