for at least 5 seconds. After the alarm is cleared an additional 10 seconds must pass (without receiving any dying gasp alarms) before
the OLT will notify the Element Management Layer that the dying gasp has been cleared.
11 ONU Data Path Configuration
The GUI may be used to configure various aspects of the ONU data path. Such as the ONU queue configuration, classification of user
data traffic and filtering of user data traffic. Because these operations are very complex the user interface is divided between several
panels.
The ONU Queue
configuration panel allows the operator to change queue sizes and save configurations.
11.1.1 Entity Selection Control
Upstream Configuration Downstream Configuration
upstream
配置
downstream
配置
The Entity Selection Control is a graphic representation of the ONU data path. This control allows the operator to select an entity to
manage by clicking on a graphical representation. An entity many be either an ONU User Port ONU Logical Link, or ONU FIFO. The EPON