EM11 User’s Manual
Appendix II
167
Code
Parameter Name
Setting range
Default
Property
C2-13
Acceleration/deceleratio
n time of simple PLC
Segment 5
0~3 0
☆
C2-14
Running time of simple
PLC Segment 6
0.0s(h)~6553.5s(h) 0.0s
(h)
☆
C2-15
Acceleration/deceleratio
n time of simple PLC
Segment 6
0~3 0
☆
C2-16
Running time of simple
PLC Segment 7
0.0s(h)~6553.5s(h) 0.0s
(h)
☆
C2-17
Acceleration/deceleratio
n time of simple PLC
Segment 7
0~3 0
☆
C2-18
Running time of simple
PLC Segment 8
0.0s(h)~6553.5s(h) 0.0s
(h)
☆
C2-19
Acceleration/deceleratio
n time of simple PLC
Segment 8
0~3 0
☆
C2-20
Running time of simple
PLC Segment 9
0.0s(h)~6553.5s(h) 0.0s
(h)
☆
C2-21
Acceleration/deceleratio
n time of simple PLC
Segment 9
0~3 0
☆
C2-22
Running time of simple
PLC Segment 10
0.0s(h)~6553.5s(h) 0.0s
(h)
☆
C2-23
Acceleration/deceleratio
n time of simple PLC
Segment 10
0~3 0
☆
C2-24
Running time of simple
PLC Segment 11
0.0s(h)~6553.5s(h) 0.0s
(h)
☆
C2-25
Acceleration/deceleratio
n time of simple PLC
Segment 11
0~3 0
☆
C2-26
Running time of simple
PLC Segment 12
0.0s(h)~6553.5s(h) 0.0s
(h)
☆
C2-27
Acceleration/deceleratio
n time of simple PLC
Segment 12
0~3 0
☆
C2-28
Running time of simple
PLC Segment 13
0.0s(h)~6553.5s(h) 0.0s
(h)
☆
C2-29
Acceleration/deceleratio
n time of simple PLC
Segment 13
0~3 0
☆
C2-30
Running time of simple
PLC Segment 14
0.0s(h)~6553.5s(h) 0.0s
(h)
☆
C2-31
Acceleration/deceleratio
n time of simple PLC
0~3 0
☆
Appendix II
EM11 User’s Manual
168
Code
Parameter Name
Setting range
Default
Property
Segment 14
C2-32
Running time of simple
PLC Segment 15
0.0s(h)~6553.5s(h) 0.0s
(h)
☆
C2-33
Acceleration/deceleratio
n time of simple PLC
Segment 15
0~3 0
☆
C2-34
Time unit of simple
PLC running
0: s (second)
1: h (hour)
0
☆
Group C3: Swing Frequency, Fixed Length and Count
C3-00
Swing frequency setting
mode
0: Relative to the central frequency
1: Relative to the maximum frequency
0
☆
C3-01
Swing frequency
amplitude
0.0%~100.0% 0.0%
☆
C3-02
Textile jump frequency
amplitude of Swing
running
0.0%~50.0% 0.0%
☆
C3-03
Swing frequency cycle 0.1s~3000.0s
10.0s
☆
C3-04
Triangular wave rising
time coefficient
0.1%~100.0% 50.0%
☆
C3-05
Set length
0m~65535 m
1000 m
☆
C3-06
Actual length
0m~65535 m
0 m
☆
C3-07
Number of pulses per
meter
0.1~6553.5 100.0
☆
C3-08
Set count value
1~65535
1000
☆
C3-09
Designated count value 1~65535
1000
☆
Group d0: Motor 1 Parameters
d0-00
Rated motor power 0.1kw~1000.0 kW
Model
dependent
★
d0-01
Rated motor voltage 1V~2000 V
Model
dependent
★
d0-02 Rated
motor
current
0.01A~655.35 A (Frequency inverter power
≤
55 kW)
0.1A~6553.5 A (Frequency inverter power
≥
75 kW)
Model
dependent
★
d0-03
Rated motor frequency 0.01 Hz~ maximum frequency
50.00Hz
★
d0-04
Rated motor rotational
speed
1rpm~65535rpm
Model
dependent
★
d0-05
Stator resistance
(asynchronous motor)
0.001
Ω
~65.535
Ω
(frequency inverter
power
≤
55 kW)
0.0001
Ω
~6.5535
Ω
(frequency inverter
power
≥
75 kW)
Model
dependent
★
d0-06
Rotor resistance
(asynchronous motor)
0.001
Ω
~65.535
Ω
(Frequency inverter
power
≤
55 kW)
0.0001
Ω
~6.5535
Ω
(Frequency inverter
power
≥
75 kW)
Model
dependent
★
d0-07
Leakage inductive
reactance (asynchronous
0.01mH~655.35 mH (Frequency inverter
power
≤
55 kW)
Model