EM11 User’s Manual
Appendix II
179
Code
Parameter Name
Setting range
Default
Property
U0-22
AI2 voltage before
correction
0.00V~10.57 V
-
●
U0-23
AI3 voltage before
correction
-10.57V~10.57 V
-
●
U0-24 Linear
speed
0.0min~65535m/min
-
●
U0-25 Present
power-on
time -
-
●
U0-26
Present running time -
-
●
U0-27
Communication setting
value
-100.00%~100.00% -
●
U0-28 Encoder feedback speed
-3000.0Hz~3000.0 Hz
-300.00Hz~300.00 Hz
-
●
U0-29 Main
frequency
X
0.00Hz~300.00 Hz
0.0Hz~3000.0 Hz
-
●
U0-30 Auxiliary
frequency
Y
0.00Hz~300.00 Hz
0.0Hz~3000.0 Hz
-
●
U0-31
Viewing any register
address value
0°C~200°C -
●
U0-32
Synchronous motor
rotor position
0.0°~ 359.9°
-
●
U0-33 Motor
temperature
0°C~200°C
-
●
U0-34 Target
torque
-200.0%~200.0%
-
●
U0-35 Resolver
position
0~4095
-
●
U0-36
Power factor angle
-
-
●
U0-37 ABZ
position
0~65535
-
●
U0-38
Target voltage of V/F
separation
0 V ~ rated motor voltage
-
●
U0-39
Output voltage of V/F
separation
0 V ~ rated motor voltage
-
●
U0-40
DI input state visual
display
- -
●
U0-41
DO output state visual
display
- -
●
U0-42
DI function state visual
display 1
- -
●
U0-43
DO function state visual
display
- -
●
U0-44 Fault
information
-
-
●
U0-45 Phase Z signal counting -
-
●
U0-46
Present setting
frequency (%)
-100.00%~100.00%
-
●
U0-47
Present running
frequency (%)
-100.00%~100.00%
-
●
U0-48
Frequency inverter
running state
0~65535
-
●
U0-49
Sent value of
point-point
communication
-100.00%~100.00%
-
●
Appendix II
EM11 User’s Manual
180
Code
Parameter Name
Setting range
Default
Property
U0-50
Received value of
point-point
communication
-100.00%~100.00%
-
●
Group A0: System Parameters
A0-00
User password
0~65535
0
☆
A0-01
Product number
Frequency inverter product number
Model
dependent
●
A0-02
Software version
Software version of control board
Model
dependent
●
A0-03
Rated current
-
Model
dependent
●
A0-04
Rated voltage
-
Model
dependent
●
A0-07
Parameter modification
property
0: Modifiable
1: Not modifiable
0
☆
A0-08
Individualized
parameter display
property
Unit's digit: User-defined parameter QUICK
display selection.
0: Not display
1: Display
Ten's digit: User-changed parameter QUICK
display selection.
0: Not display
1: Display
0
☆
A0-09
Restore default settings
0: No operation
1: Restore default settings except motor
parameters and accumulation record.
2: Restore default settings for all parameters
3: Reserve
4: Clear records
Other: Reserve
0
★
Group A1: User-defined Parameters
A1-00
User-defined function
code 0
User visible function codes
ub0.01
☆
A1-01
User-defined function
code 1
User visible function codes
ub0.02
☆
A1-02
User-defined function
code 2
User visible function codes
ub0.03
☆
A1-03
User-defined function
code 3
User visible function codes
ub0.07
☆
A1-04
User-defined function
code 4
User visible function codes
ub0.12
☆
A1-05
User-defined function
code 5
User visible function codes
ub0.21
☆
A1-06
User-defined function
code 6
User visible function codes
ub0.22
☆
A1-07
User-defined function
code 7
User visible function codes
ub3.00
☆